Fab fragments imprinted SPR biosensor for real-time human immunoglobulin G detection

被引:88
|
作者
Erturk, Gizem [2 ]
Uzun, Lokman [1 ]
Tumer, M. Askin [2 ]
Say, Ridvan [3 ]
Denizli, Adil
机构
[1] Hacettepe Univ, Dept Chem, Fac Sci, Div Biochem, TR-06532 Ankara, Turkey
[2] Hacettepe Univ, Dept Biol, TR-06532 Ankara, Turkey
[3] Anadolu Univ, Dept Chem, Eskisehir, Turkey
关键词
F-ab fragment; F-c fragment; Molecular imprinted polymers; Surface plasmon resonance sensors; Immunoglobulin G detection; ADSORPTION; AUTOANTIBODIES; PURIFICATION; SEPARATION; POLYMERS; MONOLITH; ANTIBODY; REMOVAL; SENSORS; PLASMA;
D O I
10.1016/j.bios.2011.07.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
F-ab fragments imprinted surface plasmon resonance (SPR) chip was prepared for the real-time detection of human immunoglobulin G (IgG). In order to attach polymerization precursor on SPR chip, the SPR chip surface was modified with allyl mercaptan. F-ab fragments of the IgG molecules were prepared by papain digestion procedure and collected by fast protein liquid chromatography (FPLC) system using Hi-Trap_r Protein A FF column. The collected Fab fragments were complexed with histidine containing specific monomer, N-methacryloyl-L-histidine methyl ester (MAH). Molecular imprinted polymeric nanofilm was prepared on SPR chip in the presence of ethylene glycol dimethacrylate and 2-hydroxyethylmethacrylate. The template molecules, F-ab fragments, were removed from the polymeric nanofilm using 1 M NaCl solution (pH: 7.4, phosphate buffer system). The molecular imprinted SPR chip was characterized by contact angle, atomic force microscopy and Fourier transform infrared spectroscopy. By the real-time IgG detection studies carried out using aqueous IgG solutions in different concentrations, the kinetics and isotherm parameters of the molecular imprinted SPR chip-IgG system were calculated. To show selectivity and specificity of the molecular imprinted SPR chip, competitive kinetic analyses were performed using bovine serum albumin (BSA), IgG, F-ab and F-c fragments in singular and competitive manner. As last step. IgG detection studies from human plasma were performed and the measured IgG concentrations were well matched with the results determined by enzyme-linked immunosorbent assay (ELISA). The results obtained with the molecular imprinted SPR chip were well fitted to Langmuir isotherm and the detection limit was found as 56 ng/mL. In the light of the results, we can conclude that the proposed molecular imprinted SPR chip can detect IgG molecules from both aqueous solutions and complex natural samples. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [1] Selectivity evaluation and separation of human immunoglobulin G, Fab and Fc fragments with mixed-mode resins
    Luo, Ying-Di
    Zhang, Qi-Lei
    Yuan, Xiao-Ming
    Shi, Wei
    Yao, Shan-Jing
    Lin, Dong-Qiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1040 : 105 - 111
  • [2] Preparation and separation of Fab and Fc fragments from human immunoglobulin G with papain digestion
    Tang, Siyuan
    Lin, Dongqiang
    Tong, Hongfei
    Yao, Shanjing
    Huagong Xuebao/CIESC Journal, 2013, 64 (05): : 1750 - 1756
  • [3] Immunoglobulin G recognition with Fab fragments imprinted monolithic cryogels: Evaluation of the effects of metal-ion assisted-coordination of template molecule
    Asliyuce, Sevgi
    Uzun, Lokman
    Say, Ridvan
    Denizli, Adil
    REACTIVE & FUNCTIONAL POLYMERS, 2013, 73 (06) : 813 - 820
  • [4] Microcontact imprinting based surface plasmon resonance (SPR) biosensor for real-time and ultrasensitive detection of prostate specific antigen (PSA) from clinical samples
    Erturk, Gizem
    Ozen, Haluk
    Tumer, M. Askin
    Mattiasson, Bo
    Denizli, Adil
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 : 823 - 832
  • [5] Approaching near real-time biosensing: Microfluidic microsphere based biosensor for real-time analyte detection
    Cohen, Noa
    Sabhachandani, Pooja
    Golberg, Alexander
    Konry, Tania
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 454 - 460
  • [6] A surface protein-imprinted biosensor based on boronate affinity for the detection of anti-human immunoglobulin G
    Liu, Zixuan
    Yin, Zheng-Zhi
    Cai, Wenrong
    Wu, Datong
    Li, Junyao
    Kong, Yong
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [7] ISOLATION OF FAB AND FC FRAGMENTS FROM MOUSE IMMUNOGLOBULIN-G1
    BELYAEVA, EL
    NIKONENKO, BV
    SIDOROVA, EV
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 1979, 88 (07) : 811 - 813
  • [8] An antifouling electrochemical biosensor based on a protein imprinted hydrogel for human immunoglobulin G recognition in complex biological media
    Cui, Min
    Gong, Yinghua
    Du, Meigui
    Wang, Ke
    Li, Tianduo
    Zhu, Xiaolong
    Wang, Shuai
    Luo, Xiliang
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 337
  • [9] Real-Time Detection of Fibrinogen via Imprinted Recognition Sites
    Cimen, Duygu
    Uzek, Recep
    Gunaydin, Serdar
    Denizli, Adil
    CHEMISTRYSELECT, 2021, 6 (35): : 9435 - 9441
  • [10] SPR and SPR Imaging: Recent Trends in Developing Nanodevices for Detection and Real-Time Monitoring of Biomolecular Events
    Puiu, Mihaela
    Bala, Camelia
    SENSORS, 2016, 16 (06)