A comparison between capillary and imaging techniques for sizing bubbles in flotation systems

被引:86
作者
Hernandez-Aguilar, JR
Coleman, RG
Gomez, CO
Finch, JA
机构
[1] McGill Univ, Dept Min Met & Mat Engn, Montreal, PQ H3A 2B2, Canada
[2] Univ Queensland, Julius Kruttschnitt Mineral Res Ctr, Brisbane, Qld 4068, Australia
基金
加拿大自然科学与工程研究理事会;
关键词
sizing; sampling; flotation bubbles; flotation machines;
D O I
10.1016/j.mineng.2003.09.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This communication reports a laboratory and plant comparison between the University of Cape Town (UCT) device (capillary) and the McGill University bubble sizing method (imaging). The laboratory work was conducted on single bubbles to establish the accuracy of the techniques by comparing with a reference method (capture in a burette). Single bubble measurements with the McGill University technique showed a tendency to slightly underestimate (4% for a 1.3 mm bubble) and the UCT technique to slightly overestimate (1% for the 1.3 man bubble). Both trends are anticipated from fundamental considerations. In the UCT technique bubble breakup was observed when measuring a 2.7 mm bubble using a 0.5 mm ID capillary tube. A discrepancy of 11% was determined when comparing the techniques in an industrial-scale mechanical flotation cell. The possible sources of bias are discussed. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 11 条
[1]   Sizing of bubbles by incoherent imaging: Defocus bias [J].
Bongiovanni, C ;
Chevaillier, JP ;
Fabre, J .
EXPERIMENTS IN FLUIDS, 1997, 23 (03) :209-216
[2]   Measurement of bubble size distribution in protein foam fractionation column using capillary probe with photoelectric sensors [J].
Du, LP ;
Ding, YQ ;
Prokop, A ;
Tanner, RD .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2001, 91-3 (1-9) :387-404
[3]   Visual technique for measuring bubble size in flotation machines [J].
Grau, RA ;
Heiskanen, K .
MINERALS ENGINEERING, 2002, 15 (07) :507-513
[4]  
GREAVES M, 1984, CHEM ENG RES DES, V62, P3
[5]  
Hernandez J., 2002, P 34 ANN M CAN MIN P
[6]   Bubble size distribution in the sparger region of bubble columns [J].
Polli, M ;
Di Stanislao, M ;
Bagatin, R ;
Abu Bakr, E ;
Masi, M .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (01) :197-205
[7]   A METHOD FOR MEASURING THE SIZES OF BUBBLES IN 2-PHASE AND 3-PHASE SYSTEMS [J].
RANDALL, EW ;
GOODALL, CM ;
FAIRLAMB, PM ;
DOLD, PL ;
OCONNOR, CT .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (10) :827-833
[8]   Transient two-phase flow in arbitrary inclined tubes caused by depressurization of liquid with dissolved gases [J].
Richter, S ;
Fleischer, S ;
Aritomi, M ;
Hampel, R .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (01) :1-15
[9]   AN EVALUATION OF A DIRECT METHOD OF BUBBLE-SIZE DISTRIBUTION MEASUREMENT IN A LABORATORY BATCH FLOTATION CELL [J].
TUCKER, JP ;
DEGLON, DA ;
FRANZIDIS, JP ;
HARRIS, MC ;
OCONNOR, CT .
MINERALS ENGINEERING, 1994, 7 (5-6) :667-680
[10]   Aperiodic bubble formation from a submerged orifice [J].
Zhang, L ;
Shoji, M .
CHEMICAL ENGINEERING SCIENCE, 2001, 56 (18) :5371-5381