Power Quality Measurement and Evaluation of a Wind Farm Connected to Distribution Grid

被引:10
作者
Yildiz, Ceyhun [1 ]
Kececioglu, O. Fatih [1 ]
Acikgoz, Hakan [2 ]
Gani, Ahmet [1 ]
Sekkeli, Mustafa [1 ]
机构
[1] K Maras Sutcu Imam Univ, Dept Elect Elect Engn, TR-46100 K Maras, Turkey
[2] Kilis 7 Aralik Univ, Elect Sci, TR-79000 Kilis, Turkey
来源
WORLD CONFERENCE ON TECHNOLOGY, INNOVATION AND ENTREPRENEURSHIP | 2015年
关键词
Wind farm; power quality; Harmonic;
D O I
10.1016/j.sbspro.2015.06.211
中图分类号
F [经济];
学科分类号
02 ;
摘要
Wind power can bring new challenges when it is connected to the power grid. Generated power from wind energy system is always fluctuating due to the fluctuations in the wind. This paper shows a study on Power Quality (PQ) analysis of wind turbines installed in Hatay region and has been working for three years. Power quality parameters such as voltage, current, active, reactive and apparent power and harmonics are measured, analyzed and evaluated taking into consideration IEEE 519-1992 standards. These parameters are continuously measured for three months. The recorded parameters are voltage and current rms values of all single phase for every 10 power frequency cycles, average values of current and voltage harmonics every 3 sec, active, reactive, and apparent power values and the power factor every second. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:2370 / 2375
页数:6
相关论文
共 15 条
[1]  
[Anonymous], 1992, 5191992 IEEE
[2]   Wind farm-A power source in future power systems [J].
Chen, Z. ;
Blaabjerg, F. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (6-7) :1288-1300
[3]  
Ertay MM, 2012, ENER EDUC SCI TECH-A, V29, P1253
[4]   Measuring electric power quality: Problems and perspectives [J].
Ferrero, Alessandro .
MEASUREMENT, 2008, 41 (02) :121-129
[5]   Effect of nonlinear energy on wind farm generators connected to a distribution grid [J].
Hocine, Labar ;
Mounira, Mekki .
ENERGY, 2011, 36 (05) :3255-3261
[6]  
Imal, 2012, ENERG ED SCI TECH A, V30, P565
[7]   Power quality assessment of grid-connected wind farms considering regulations in turkey [J].
Kocatepe, Celal ;
Inan, Asian ;
Arikan, Oktay ;
Yumurtaci, Recep ;
Kekezoglu, Bedri ;
Baysal, Mustafa ;
Bozkurt, Altug ;
Akkaya, Yener .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (09) :2553-2561
[8]   Optimization of wind turbine energy and power factor with an evolutionary computation algorithm [J].
Kusiak, Andrew ;
Zheng, Haiyang .
ENERGY, 2010, 35 (03) :1324-1332
[9]   Power quality analysis of wind farm connected to Alacati substation in Turkey [J].
Mutlu, Oezgur Salih ;
Akpinar, Eyuep ;
Balikci, Abduel .
RENEWABLE ENERGY, 2009, 34 (05) :1312-1318
[10]   Power-quality measurements in an autonomous island grid with high wind penetration [J].
Papathanassiou, SA ;
Santjer, F .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) :218-224