Analysis of Fine Crack Images Using Image Processing Technique and High-Resolution Camera

被引:5
|
作者
Jeong, Hoseong [1 ]
Jeong, Baekeun [2 ]
Han, Myounghee [2 ]
Cho, Dooyong [2 ]
机构
[1] Chungnam Natl Univ, Inst Agr Sci, 99 Daehak Ro, Daejeon 34134, South Korea
[2] Chungnam Natl Univ, Dept Convergence Syst Engn, 99 Daehak Ro, Daejeon 34134, South Korea
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 20期
关键词
crack measurement; image processing; high resolution; working distance; crack width; visual inspection; structure state assessment; ground sample distance (GSD);
D O I
10.3390/app11209714
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application:& nbsp;Analysis of Fine Cracks.</p> <br></p> Visual inspections are performed to investigate cracks in concrete infrastructure. These activities require manpower or equipment such as articulated ladders. Additionally, there are health and safety issues because some structures have low accessibility. To deal with these problems, crack measurement with digital images and digital image processing (DIP) techniques have been adopted in various studies. The objective of this experimental study is to evaluate the optical limit of digital camera lenses as working distance increases. Three different lenses and two digital cameras were used to capture images of lines ranging from 0.1 to 0.5 mm in thickness. As a result of the experiments, it was found that many elements affect width measurement. However, crack width measurement is dependent on the measured pixel values. To accurately measure width, the measured pixel values must be in decimal units, but that is theoretically impossible. According to the results, in the case of 0.3 mm wide or wider cracks, a working distance of 1 m was secured when the focal length was 50 mm, and working distances of 3 m and 4 m were secured when the focal length was 100 mm and 135 mm, respectively. However, for cracks not wider than 0.1 mm, focal lengths of 100 mm and 135 mm showed measurability within 1 m, but a focal length of 50 mm was judged to hardly enable measurement except for certain working positions. Field measurement tests were conducted to verify measurement parameters identified by the results of the indoor experiment. The widths of actual cracks were measured through visual inspection and used for the analysis. From the evaluation, it was confirmed that the number of pixels corresponding to the working distance had a great influence on crack width measurement accuracy when using image processing. Therefore, the optimal distance and measurement guidelines required for the measurement of the size of certain objects was presented for the imaging equipment and optical equipment applied in this study.</p>
引用
收藏
页数:23
相关论文
共 50 条
  • [1] AN ANALYSIS OF HIGH-RESOLUTION IMAGES BY DIGITAL PROCESSING
    PEREZRAMIREZ, JG
    MAZEROLLES, L
    MICHEL, D
    PORTIER, R
    CHEVALIER, JP
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1988, 13 (03): : A56 - A56
  • [2] Image Stepper: High-resolution image processing using distributed computing
    Tympel, V
    Witt, R
    Layland, S
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XVII, PTS 1 AND 2, 2003, 5038 : 733 - 740
  • [3] HIGH-RESOLUTION IMAGE-PROCESSING
    DORIGNAC, D
    JOUFFREY, B
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1979, 4 (03): : A9 - A9
  • [4] Design of image storage and processing system for Tianwen-1 high-resolution camera
    Wang Z.
    He Y.
    Sun X.
    Wu F.
    Wang D.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2022, 30 (02): : 127 - 136
  • [5] High-Speed Satellite Detection in High-Resolution Image Using Image Processing
    Shin, Seunghyeok
    Lee, Jongmin
    Lee, Sangwook
    Yang, Taeseok
    Kim, Whoi-Yul
    JOURNAL OF THE KOREAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, 2018, 46 (05) : 427 - 435
  • [6] High Resolution Image Processing Technique for the Detection of Metal Entrapments based on a Terahertz Camera
    Friederich, B.
    Damyanov, D.
    Kohl, J.
    Kolpatzeck, K.
    Liu, X.
    Schultze, T.
    Czylwik, A.
    Balzer, J. C.
    Willms, I
    2019 44TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2019,
  • [7] Fine-grained crack segmentation for high-resolution images via a multiscale cascaded network
    Chu, Honghu
    Chun, Pang-jo
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2024, 39 (04) : 575 - 594
  • [8] Detection of atmospheric Cherenkov images of air showers using high-resolution and high-speed camera system with image intensifiers
    Tada, I.
    Yamada, Y.
    Imakura, M.
    Sumitomo, R.
    Noguchi, Y.
    Tsuchitori, S.
    Kajino, F.
    Yamamoto, Y.
    Sakata, M.
    Proceedings of the 29th International Cosmic Ray Conference, Vol 5: OG 2.5, 2.6 & 2.7, 2005, : 339 - 342
  • [9] A Crack Width Measurement Method of UAV Images Using High-Resolution Algorithms
    Yoon, Jonghyeon
    Shin, Hyunkyu
    Song, Mihwa
    Gil, Heungbae
    Lee, Sanghyo
    SUSTAINABILITY, 2023, 15 (01)
  • [10] Evolution of Crack Analysis in Structures Using Image Processing Technique: A Review
    Azouz, Zakrya
    Asli, Barmak Honarvar Shakibaei
    Khan, Muhammad
    ELECTRONICS, 2023, 12 (18)