The impact of steerable sheaths on unblinded contact force during catheter ablation for atrial fibrillation

被引:20
作者
Deyell, Marc W. [1 ]
Wen, Glen [1 ]
Laksman, Zachary [1 ]
Bennett, Matthew T. [1 ]
Chakrabarti, Santabhanu [1 ]
Yeung-Lai-Wah, John A. [1 ]
Krahn, Andrew D. [1 ]
Andrade, Jason G. [1 ]
机构
[1] Univ British Columbia, Heart Rhythm Serv, Div Cardiol, Dept Med, 211-1033 Davie St, Vancouver, BC V6E 1M7, Canada
关键词
Atrial fibrillation; Catheter ablation; Contact force; Steerable sheath; PULMONARY VEIN ISOLATION; RANDOMIZED-TRIAL; SOCIETY;
D O I
10.1007/s10840-019-00514-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The purpose of this study was to evaluate the impact of steerable sheaths on multiple contact force parameters during atrial fibrillation (AF) ablation. Steerable sheaths are commonly used during AF ablation, at an additional cost to standard fixed-curve sheaths. However, there is little data on their incremental value in the era of contact force-guided radiofrequency ablation. Methods This multi-center cohort study included consecutive patients undergoing index pulmonary vein (PV) isolation with a force-sensing catheter. Operators employed either only steerable or only fixed-curve sheaths. Operators targeted a force of 10-40 g for each ablation lesion. Automated ablation lesion assessment software with standardized settings was employed. Results Of 85 subjects, 52 and 33 underwent ablation with steerable and fixed-curve sheaths, respectively. The steerable sheath group showed significantly higher average and maximum forces, but predominantly for the right PVs. The proportion of lesions with >= 10% of time with less than 10 g of force was lower in the steerable sheath group (adjusted odds ratio 0.56, steerable vs. fixed; 95% confidence interval 0.35, 0.89, p = 0.01). Improved stability was seen in the posterior aspect of both PV pairs. The proportion of RF time-in-target (the proportion of RF time meeting lesion criteria) was not different between the two groups (p = 0.176). Conclusions Even with contemporary contact force targets, steerable sheath use in AF ablation is associated with better average and maximum contact force and increased stability in comparison to fixed-curve sheaths.
引用
收藏
页码:417 / 424
页数:8
相关论文
共 17 条
  • [11] A randomized trial to compare atrial fibrillation ablation using a steerable vs. a non-steerable sheath
    Rajappan, Kim
    Baker, Victoria
    Richmond, Laura
    Kistler, Peter M.
    Thomas, Glyn
    Redpath, Calum
    Sporton, Simon C.
    Earley, Mark J.
    Harris, Stuart
    Schilling, Richard J.
    [J]. EUROPACE, 2009, 11 (05): : 571 - 575
  • [12] Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study
    Reddy, Vivek Y.
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Natale, Andrea
    Albenque, Jean-Paul
    Kautzner, Josef
    Shah, Dipen
    Michaud, Gregory
    Wharton, Marcus
    Harari, David
    Mahapatra, Srijoy
    Lambert, Hendrik
    Mansour, Moussa
    [J]. CIRCULATION, 2015, 132 (10) : 907 - 915
  • [13] Real-Time Contact Force Measurement A Key Parameter for Controlling Lesion Creation With Radiofrequency Energy
    Shah, Dipen C.
    Namdar, Mehdi
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (03) : 713 - 721
  • [14] Ullah W, 2016, J Atr Fibrillation, V8, P1282, DOI 10.4022/jafib.1282
  • [15] Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data
    Ullah, Waqas
    McLean, Ailsa
    Tayebjee, Muzahir H.
    Gupta, Dhiraj
    Ginks, Matthew R.
    Haywood, Guy A.
    O'Neill, Mark
    Lambiase, Pier D.
    Earley, Mark J.
    Schilling, Richard J.
    [J]. HEART RHYTHM, 2016, 13 (09) : 1761 - 1767
  • [16] Canadian Cardiovascular Society Atrial Fibrillation Guidelines 2010: Catheter Ablation for Atrial Fibrillation/Atrial Flutter
    Verma, Atul
    Macle, Laurent
    Cox, Jafna
    Skanes, Allan C.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (01) : 60 - 66
  • [17] Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and Thrombus
    Yokoyama, Katsuaki
    Nakagawa, Hiroshi
    Shah, Dipen C.
    Lambert, Hendrik
    Leo, Giovanni
    Aeby, Nicolas
    Ikeda, Atsushi
    Pitha, Jan V.
    Sharma, Tushar
    Lazzara, Ralph
    Jackman, Warren M.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2008, 1 (05) : 354 - 362