Two-photon fluorescence microscopy signal formation in highly scattering media: theoretical and numerical simulation

被引:8
作者
Sergeeva, E. A. [1 ]
Katichev, A. R. [1 ]
Kirillin, M. Yu. [1 ]
机构
[1] Russian Acad Sci, Inst Appl Phys, Nizhnii Novgorod 603950, Russia
基金
俄罗斯基础研究基金会;
关键词
two-photon fluorescence microscopy; multiple scattering; radiative transfer theory; small-angle diffusion approximation; Monte Carlo simulation; focused Gaussian beam; IMAGING-DEPTH LIMIT; MONTE-CARLO; EXCITATION FLUORESCENCE; OPTICAL-PROPERTIES; PHASE FUNCTIONS; LIGHT; COLLECTION; SECTIONS;
D O I
10.1070/QE2010v040n12ABEH014506
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using the radiative transfer theory and Monte Carlo simulations, we analyse the effect of scattering in a medium and of the size of the detector pinhole on the formation of the fluorescent signal in standard two-photon fluorescence microscopy (TPFM) systems. The theoretical analysis is based on a small-angle diffusion approximation of the radiative transfer equation, adapted to calculate the propagation of focused infrared radiation in media similar to the biological tissues in their optical properties. The accuracy of the model is evaluated by comparing the calculated excitation intensity in a highly scattering medium with the results of Monte Carlo simulations. To simulate a tightly focused Gaussian beam by the Monte Carlo method, the so called 'ray-optics' approach that correctly takes into account the finite size and shape of the beam waist is applied. It is shown that in the combined confocal and two-photon scanning microscopy systems not equipped with an external 'nondescanned' detector, the scattering significantly affects both the nonlinear excitation efficiency in the medium and the fluorescence collection efficiency of the system. In such systems, the rate of the useful TPFM signal in-depth decay is 1.5-2 times higher than in systems equipped with a 'nondescanned' detector.
引用
收藏
页码:1053 / 1061
页数:9
相关论文
共 46 条
  • [31] Rapid, high-contrast, and steady volumetric imaging with Bessel-beam-based two-photon fluorescence microscopy
    Chen, Yongqiang
    Luo, Chenggui
    Wang, Shiqi
    Li, Yanping
    Shen, Binglin
    Hu, Rui
    Qu, Junle
    Liu, Liwei
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (01)
  • [32] Robust quantification of microvascular transit times via linear dynamical systems using two-photon fluorescence microscopy data
    Chinta, Lakshminarayan V.
    Lindvere, Liis
    Stefanovic, Bojana
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2012, 32 (09) : 1718 - 1724
  • [33] Effect of photons of different scattering orders on the formation of a signal in optical low-coherence tomography of highly scattering media
    Kirillin, M. Yu.
    Meglinski, I. V.
    Priezzhev, A. V.
    QUANTUM ELECTRONICS, 2006, 36 (03) : 247 - 252
  • [34] Efficient large core fiber-based detection for multi-channel two-photon fluorescence microscopy and spectral unmixing
    Ducros, Mathieu
    van't Hoff, Marcel
    Evrard, Alexis
    Seebacher, Christian
    Schmidt, Elke M.
    Charpak, Serge
    Oheim, Martin
    JOURNAL OF NEUROSCIENCE METHODS, 2011, 198 (02) : 172 - 180
  • [35] A stage-scanning two-photon microscope equipped with a temporal and a spatial pulse shaper: Enhance fluorescence signal by phase shaping
    Buechau, Frederik
    Patas, Alexander
    Yang, Yang
    Lindinger, Albrecht
    Heyne, Karsten
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (12)
  • [36] Two-component molecular cocrystals of 9-acetylanthracene with highly tunable one-/two-photon fluorescence and aggregation induced emission
    Li, Shuzhen
    Lin, Yanjun
    Yan, Dongpeng
    JOURNAL OF MATERIALS CHEMISTRY C, 2016, 4 (13) : 2527 - 2534
  • [37] Out-of-focus signal rejection for in vivo pO2 measurements using two-photon phosphorescence lifetime microscopy
    Pian, Qi
    Li, Baoqiang
    Sencan-Egilmez, Ikbal
    Cheng, Xiaojun
    Dubb, Jay
    Huang, Xinyue
    Fu, Buyin
    Allu, Srinivasa Rao
    Yaseen, Mohammad Abbas
    Devor, Anna
    Vinogradov, Sergei A.
    Sakadzic, Sava
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (01): : 159 - 176
  • [38] Fast Two-snapshot Structured Illumination for Wide-field Two-photon Microscopy with Enhanced Axial Resolution and Signal-to-noise Ratio
    Meng, Yunlong
    Lin, Wei
    Chen, Jialong
    Li, Chenglin
    Chen, Shih-Chi
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [39] Volumetric label-free imaging and 3D reconstruction of mammalian cochlea based on two-photon excitation fluorescence microscopy
    Zhang, Xianzeng
    Geng, Yang
    Ye, Qing
    Zhan, Zhenlin
    Xie, Shusen
    LASER PHYSICS, 2013, 23 (11)
  • [40] Three-dimensional laser scanning two-photon fluorescence confocal microscopy of polymer materials using a new, efficient upconverting fluorophore
    Bhawalkar, JD
    Swiatkiewicz, J
    Pan, SJ
    Samarabandu, JK
    Liou, WS
    He, GS
    Berezney, R
    Cheng, PC
    Prasad, PN
    SCANNING, 1996, 18 (08) : 562 - 566