Comparison of Newtonian and Non-newtonian Fluid Models in Blood Flow Simulation in Patients With Intracranial Arterial Stenosis

被引:62
|
作者
Liu, Haipeng [1 ,2 ,3 ]
Lan, Linfang [1 ]
Abrigo, Jill [2 ]
Ip, Hing Lung [1 ]
Soo, Yannie [1 ]
Zheng, Dingchang [3 ]
Wong, Ka Sing [1 ]
Wang, Defeng [2 ]
Shi, Lin [2 ]
Leung, Thomas W. [1 ]
Leng, Xinyi [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Med & Therapeut, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Imaging & Intervent Radiol, Hong Kong, Peoples R China
[3] Coventry Univ, Res Ctr Intelligent Healthcare, Coventry, W Midlands, England
来源
FRONTIERS IN PHYSIOLOGY | 2021年 / 12卷
基金
中国国家自然科学基金;
关键词
non-Newtonian fluid; intracranial atherosclerotic stenosis; computational fluid dynamics; translesional pressure ratio; wall shear stress; WALL SHEAR-STRESS; FRACTIONAL FLOW; DYNAMICS; CFD; HEMODYNAMICS; VISCOSITY; ANEURYSMS; PRESSURE; WILLIS; IMPACT;
D O I
10.3389/fphys.2021.718540
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background Newtonian fluid model has been commonly applied in simulating cerebral blood flow in intracranial atherosclerotic stenosis (ICAS) cases using computational fluid dynamics (CFD) modeling, while blood is a shear-thinning non-Newtonian fluid. We aimed to investigate the differences of cerebral hemodynamic metrics quantified in CFD models built with Newtonian and non-Newtonian fluid assumptions, in patients with ICAS. Methods We built a virtual artery model with an eccentric 75% stenosis and performed static CFD simulation. We also constructed CFD models in three patients with ICAS of different severities in the luminal stenosis. We performed static simulations on these models with Newtonian and two non-Newtonian (Casson and Carreau-Yasuda) fluid models. We also performed transient simulations on another patient-specific model. We measured translesional pressure ratio (PR) and wall shear stress (WSS) values in all CFD models, to reflect the changes in pressure and WSS across a stenotic lesion. In all the simulations, we compared the PR and WSS values in CFD models derived with Newtonian, Casson, and Carreau-Yasuda fluid assumptions. Results In all the static and transient simulations, the Newtonian/non-Newtonian difference on PR value was negligible. As to WSS, in static models (virtual and patient-specific), the rheological difference was not obvious in areas with high WSS, but observable in low WSS areas. In the transient model, the rheological difference of WSS areas with low WSS was enhanced, especially during diastolic period. Conclusion Newtonian fluid model could be applicable for PR calculation, but caution needs to be taken when using the Newtonian assumption in simulating WSS especially in severe ICAS cases.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Comparison of Newtonian and Non-newtonian Fluid Models in Blood Flow Simulation in Patients With Intracranial Arterial Stenosis (vol 12, 718540, 2021)
    Liu, Haipeng
    Lan, Linfang
    Abrigo, Jill
    Ip, Hing Lung
    Soo, Yannie
    Zheng, Dingchang
    Wong, Ka Sing
    Wang, Defeng
    Shi, Lin
    Leung, Thomas W.
    Leng, Xinyi
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [2] NON-NEWTONIAN MODELS FOR BLOOD FLOW THROUGH AN ARTERIAL STENOSIS
    Tazyukov, F. Kh.
    Khalaf, H. A.
    Hassan, Jafar M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 1, 2012, : 831 - +
  • [3] A computer simulation of blood flow in arterial networks, including blood non-Newtonian models and arterial stenosis
    Dabiri, Yaghoub
    Fatouraee, Nasser
    Katoozian, Hamid
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2312 - 2315
  • [4] Flow properties of Newtonian and non-Newtonian fluid downstream of stenosis
    Ookawara, S
    Ogawa, K
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2000, 33 (04) : 582 - 590
  • [5] Non-Newtonian Arterial Blood Flow through an Overlapping Stenosis
    Srivastava, V. P.
    Mishra, Shailesh
    Rastogi, Rati
    APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2010, 5 (01): : 225 - 238
  • [6] Modeling and numerical simulation of non-Newtonian arterial blood flow for mild to severe stenosis
    Nadeem, Sohail
    Ali, Shahbaz
    Akkurt, Nevzat
    Ben Hamida, Mohamed Bechir
    Almutairi, Shahah
    Ghazwani, Hassan Ali
    Eldin, Sayed M.
    Khan, Zareen A.
    Al-Shafay, A. S.
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 72 : 195 - 211
  • [7] Modeling Blood Flow Through Intracranial Aneurysms: A Comparison of Newtonian and Non-Newtonian Viscosity
    Carty, Gregory
    Chatpun, Surapong
    Espino, Daniel M.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (03) : 396 - 409
  • [8] Modeling Blood Flow Through Intracranial Aneurysms: A Comparison of Newtonian and Non-Newtonian Viscosity
    Gregory Carty
    Surapong Chatpun
    Daniel M. Espino
    Journal of Medical and Biological Engineering, 2016, 36 : 396 - 409
  • [9] Effects of Swirling on Non-Newtonian Fluid Flow through Arterial Stenosis
    Sami, Kazi Shafi
    Ali, Mohammad
    Islam, Md Quamrul
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME2019), 2021, 2324
  • [10] LES of non-Newtonian physiological blood flow in a model of arterial stenosis
    Molla, M. M.
    Paul, M. C.
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (08) : 1079 - 1087