Polarization-maintaining fiber-based optical low-coherence reflectometer for characterization and ranging of birefringence

被引:50
作者
Davé, DP [1 ]
Akkin, T [1 ]
Milner, TE [1 ]
机构
[1] Univ Texas, Dept Biomed Engn, Austin, TX 78712 USA
关键词
D O I
10.1364/OL.28.001775
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a polarization-maintaining fiber-based polarization-sensitive optical low-coherence reflectometer for measurement of depth-resolved birefringence. Unlike for other fiber-based polarization-sensitive optical low-coherence reflectometers, here the linear birefringence of a sample can be measured from data recorded in a single A scan. Simultaneous measurement of retardation and orientation of birefringent axes with mica wave plates is demonstrated. The measured retardation is insensitive to sample rotation in the plane perpendicular to ranging. (C) 2003 Optical Society of America.
引用
收藏
页码:1775 / 1777
页数:3
相关论文
共 10 条
  • [1] CATTANEO S, 2002, PHYS REV LETT, V88, P215
  • [2] Precise beat length measurement of birefringent fibres with dual channel low-coherence reflectometer
    Davé, DP
    Milner, TE
    [J]. ELECTRONICS LETTERS, 2001, 37 (04) : 215 - 216
  • [3] Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography
    deBoer, JF
    Milner, TE
    vanGemert, MJC
    Nelson, JS
    [J]. OPTICS LETTERS, 1997, 22 (12) : 934 - 936
  • [4] POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING
    HEE, MR
    HUANG, D
    SWANSON, EA
    FUJIMOTO, JG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) : 903 - 908
  • [5] Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography
    Hitzenberger, CK
    Götzinger, E
    Sticker, M
    Pircher, M
    Fercher, AF
    [J]. OPTICS EXPRESS, 2001, 9 (13): : 780 - 790
  • [6] ROTH JE, 1997, OPT LETT, V22, P934
  • [7] High-speed fiber-based polarization-sensitive optical coherence tomography of in vivo human skin
    Saxer, CE
    de Boer, JF
    Park, BH
    Zhao, YH
    Chen, ZP
    Nelson, JS
    [J]. OPTICS LETTERS, 2000, 25 (18) : 1355 - 1357
  • [8] Swanson EA, 1995, United States Patent, Patent No. [5,459,570, 5459570]
  • [9] High-speed phase- and group-delay scanning with a grating-based phase control delay line
    Tearney, GJ
    Bouma, BE
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1997, 22 (23) : 1811 - 1813
  • [10] Accuracy assessment of a linear birefringence measurement system using a Soleil-Babinet compensator
    Wang, BL
    Hellman, W
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11) : 4066 - 4070