Extended imaging volume in cone-beam x-ray tomography using the weighted simultaneous iterative reconstruction technique

被引:8
作者
Sanctorum, Joaquim G. [1 ]
Van Wassenbergh, Sam [2 ]
Van Nguyen [3 ]
De Beenhouwer, Jan [3 ]
Sijbers, Jan [3 ]
Dirckx, Joris J. J. [1 ]
机构
[1] Univ Antwerp, Lab Biophys & Biomed Phys BIMEF, Antwerp, Belgium
[2] Univ Antwerp, Lab Funct Morphol FunMorph, Antwerp, Belgium
[3] Univ Antwerp, Imec Vis Lab, Antwerp, Belgium
关键词
x-ray tomography; detector offset; field-of-view; image intensifier; cone-beam; SIRT; CT;
D O I
10.1088/1361-6560/ac16bc
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An issue in computerized x-ray tomography is the limited size of available detectors relative to objects of interest. A solution was provided in the past two decades by positioning the detector in a lateral offset position, increasing the effective field of view (FOV) and thus the diameter of the reconstructed volume. However, this introduced artifacts in the obtained reconstructions, caused by projection truncation and data redundancy. These issues can be addressed by incorporating an additional data weighting step in the reconstruction algorithms, known as redundancy weighting. In this work, we present an implementation of redundancy weighting in the widely-used simultaneous iterative reconstruction technique (SIRT), yielding the weighted SIRT (W-SIRT) method. The new technique is validated using geometric phantoms and a rabbit specimen, by performing both simulation studies as well as physical experiments. The experiments are carried out in a highly flexible stereoscopic x-ray system equipped with x-ray image intensifiers (XRIIs). The simulations showed that higher values of contrast-to-noise ratio could be obtained using the W-SIRT approach as compared to a weighted implementation of the simultaneous algebraic reconstruction technique (SART). The convergence rate of the W-SIRT was accelerated by including a relaxation parameter in the W-SIRT algorithm, creating the aW-SIRT algorithm. This allowed to obtain the same results as the W-SIRT algorithm, but at half the number of iterations, yielding a much shorter computation time. The aW-SIRT algorithm has proven to perform well for both large as well as small regions of overlap, outperforming the pre-convolutional Feldkamp-David-Kress algorithm for small overlap regions (or large detector offsets). The experiments confirmed the results of the simulations. Using the aW-SIRT algorithm, the effective FOV was increased by >75%, only limited by experimental constraints. Although an XRII is used in this work, the method readily applies to flat-panel detectors as well.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Coded cone-beam x-ray diffraction tomography with a low-brilliance tabletop source
    Zhu, Zheyuan
    Ellis, Ryan A.
    Pang, Shuo
    OPTICA, 2018, 5 (06): : 733 - 738
  • [22] Forensic imaging of projectiles using cone-beam computed tomography
    von See, Constantin
    Bormann, Kai-Hendrik
    Schumann, Paul
    Goetz, Friedrich
    Gellrich, Nils-Claudius
    Ruecker, Martin
    FORENSIC SCIENCE INTERNATIONAL, 2009, 190 (1-3) : 38 - 41
  • [23] Cone beam x-ray luminescence computed tomography: A feasibility study
    Chen, Dongmei
    Zhu, Shouping
    Yi, Huangjian
    Zhang, Xianghan
    Chen, Duofang
    Liang, Jimin
    Tian, Jie
    MEDICAL PHYSICS, 2013, 40 (03)
  • [24] Alternative grating designs for cone-beam edge illumination X-ray phase contrast imaging
    Vanthienen, P-J
    Sanctorum, J.
    Huyge, B.
    Six, N.
    Sijbers, J.
    De Beenhouwer, J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [25] Optimised x-ray source scanning trajectories for iterative reconstruction in high cone-angle tomography
    Kingston, Andrew M.
    Myers, Glenn R.
    Latham, Shane J.
    Li, Heyang
    Veldkamp, Jan P.
    Sheppard, Adrian P.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [26] HALF-SCAN CONE-BEAM X-RAY MICROTOMOGRAPHY FORMULA
    WANG, G
    LIU, Y
    LIN, TH
    CHENG, PC
    SCANNING, 1994, 16 (04) : 216 - 220
  • [27] Iterative reconstruction algorithm for half-cover dual helical cone-beam computed tomography
    Zhao, Yunsong
    Zou, Xiaobing
    Yu, Wei
    INSIGHT, 2013, 55 (05) : 232 - 236
  • [28] Magnitude and effects of X-ray scatter of a cone-beam micro-CT for small animal imaging
    Ni, Y. C.
    Jan, M. L.
    Chen, K. W.
    Cheng, Y. D.
    Chuang, K. S.
    Fu, Y. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02) : 245 - 249
  • [29] Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy
    Karius, Andre
    Karolczak, Marek
    Strnad, Vratislav
    Bert, Christoph
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):
  • [30] Extending Imaging Volume in Soft X-Ray Tomography
    Ekman, Axel
    Chen, Jian-Hua
    Vanslembrouck, Bieke
    Loconte, Valentina
    Larabell, Carolyn A. A.
    Le Gros, Mark A. A.
    Weinhardt, Venera
    ADVANCED PHOTONICS RESEARCH, 2023, 4 (04):