Influence of Dental Composite Viscosity in Attachment Reproduction: An Experimental in Vitro Study

被引:26
作者
D'Anto, Vincenzo [1 ]
Muraglie, Simone [2 ]
Castellano, Beatrice [2 ]
Candida, Ettore [2 ]
Sfondrini, Maria Francesca [3 ]
Scribante, Andrea [3 ]
Grippaudo, Cristina [4 ]
机构
[1] Univ Naples Federico II, Dept Neurosci Reprod Sci & Dent, I-80138 Naples, Italy
[2] Univ Cattolica Sacro Cuore, Inst Dent, I-00195 Rome, Italy
[3] Univ Pavia, Dept Clin Surg Diagnost & Pediat Sci, Sect Dent, Unit Orthodont & Pediat Dent, I-27100 Pavia, Italy
[4] Univ Cattolica Sacro Cuore, Inst Dent, Fdn Policlin Gemelli IRCCS, Head & Neck Dept, I-00195 Rome, Italy
关键词
orthodontics; attachments; composite resin; clear aligners; detail reproduction; viscosity degree; CLEAR ALIGNERS;
D O I
10.3390/ma12234001
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Background: Attachments are composite auxiliaries that are used during a clear aligner orthodontic therapy to achieve difficult tooth movements. Two important factors are the planned configuration and the actual position of these auxiliary elements to obtain the desired force system. The aim of the present study was to evaluate the role of different composite materials in the correct reproduction of attachment shape and position. Methods: The materials that were considered in the study were a flowable resin, a dental restorative material, and an orthodontic composite. The attachments were created on three models of extracted teeth. Once the impressions were performed, 25 attachments of different shapes were added onto each virtual model to obtain the necessary templates to make the attachments. Each tested material was used to create a set of 25 attachments that were then scanned with an accuracy of 10 mu m. The resultant STL (stereolithography) files were superimposed onto the ones from the initial virtual plan, through Geomagic software, and the aligned scans were then compared while using a color map. The parameters that were calculated to make a comparison between the created attachments and the ideal ones were the maximum deviation in defect and in excess, the overflow, and the volume's difference. In addition to these measurements comparing the three above-mentioned groups, the difference in volume between all the ideal and realized samples were analyzed. To test for differences among the three groups, a one-way Analysis of variance (ANOVA) was used with a Bonferroni post-hoc test. The level of significance was set at p < 0.05. Results: No statistically significant results were found between the three groups regarding the maximum value in defect, the maximum value in excess, and the minimum value as control, while a statistically significant difference was found between the overflow of orthodontic resin when compared to the flowable composite. Conclusions: The three materials that were used in this study were appropriate for attachment fabrication. The fidelity of attachment reproduction was similar when using the three different composites. The orthodontic composite showed more overflow when compared with the flowable one.
引用
收藏
页数:13
相关论文
共 25 条
  • [1] Barreda Graciela J, 2017, Acta odontol. latinoam., V30, P90
  • [2] A characterization of first-generation flowable composites
    Bayne, SC
    Thompson, JY
    Swift, EJ
    Stamatiades, P
    Wilkerson, M
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1998, 129 (05) : 567 - 577
  • [3] Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study
    Bucci, Rosaria
    Rongo, Roberto
    Levate, Carmine
    Michelotti, Ambrosina
    Barone, Sandro
    Razionale, Armando Viviano
    D'Anto, Vincenzo
    [J]. PROGRESS IN ORTHODONTICS, 2019, 20 (01)
  • [4] Resin-modified glass ionomer cement versus composite for orthodontic bonding: The need for standardization
    Caetano, Paula Liparini
    Werneck, Carolina de Sa
    Farinazzo Vitral, Robert Willer
    da Silva Campos, Marcio Jose
    de Faria, Fernanda Ramos
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (01) : 5 - 6
  • [5] Choi K K, 2000, J Esthet Dent, V12, P216, DOI 10.1111/j.1708-8240.2000.tb00224.x
  • [6] Effects of variable attachment shapes and aligner material on aligner retention
    Dasy, Hiltrud
    Dasy, Andreas
    Asatrian, Greg
    Rozsa, Noemi
    Lee, Hao-Fu
    Kwak, Jin Hee
    [J]. ANGLE ORTHODONTIST, 2015, 85 (06) : 934 - 940
  • [7] Fahmi Mohammed K, 2019, J Contemp Dent Pract, V20, P822
  • [8] Feinberg Katelyn Bowman, 2016, J Clin Orthod, V50, P170
  • [9] Resin composite-State of the art
    Ferracane, Jack L.
    [J]. DENTAL MATERIALS, 2011, 27 (01) : 29 - 38
  • [10] Garino Francesco, 2016, J Clin Orthod, V50, P341