Biocompatibility and pathways of initial complement pathway activation with Phisio- and PMEA-coated cardiopulmonary bypass circuits during open-heart surgery

被引:12
|
作者
Thiara, A. S. [1 ]
Mollnes, T. E. [2 ,3 ,4 ,5 ]
Videm, V. [7 ,8 ]
Andersen, V. Y. [1 ]
Svennevig, K. [6 ]
Kolset, S. O. [6 ]
Fiane, A. E. [1 ,5 ]
机构
[1] Oslo Univ Hosp, Dept Thorac & Cardiovasc Surg, N-0027 Oslo, Norway
[2] Oslo Univ Hosp, Inst Immunol, N-0027 Oslo, Norway
[3] Nordland Hosp, Bodo, Nepal
[4] Univ Tromso, N-9001 Tromso, Norway
[5] Univ Oslo, Rikshosp, Fac Div, N-0027 Oslo, Norway
[6] Univ Oslo, Inst Basic Med Sci, Dept Nutr, Oslo, Norway
[7] Norwegian Univ Sci & Technol, Inst Lab Med Childrens & Womens Hlth, N-7034 Trondheim, Norway
[8] Univ Trondheim Hosp, Dept Immunol & Transfus Med, Trondheim, Norway
来源
PERFUSION-UK | 2011年 / 26卷 / 02期
关键词
biocompatibility; CPB; Phisio; PMEA; complement pathways; inflammation; SYSTEMIC INFLAMMATORY RESPONSE; LINKED IMMUNOSORBENT-ASSAY; EXTRACORPOREAL-CIRCULATION; CLASSICAL PATHWAY; QUANTIFICATION; NEOEPITOPE; HEPARIN; HEMOCOMPATIBILITY; FIBRINOLYSIS; OXYGENATORS;
D O I
10.1177/0267659110392438
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A randomized open-heart surgery study comprising 30 patients was undertaken to compare the biocompatibility of Phisio-(phosphorylcholine) and PMEA-(poly-2-methoxyethyl acrylate) coated cardiopulmonary bypass (CPB) circuits and to assess the initial complement pathway activation during open-heart surgery. Blood samples were obtained at five time points, from the start of surgery to 24 hours postoperatively. The following analyses were performed: haemoglobin, lactate dehydrogenase, leukocyte and platelet counts, myeloperoxidase and neutrophil-activating peptide-2, thrombin-anti-thrombin complexes, syndecan-1 and the complement activation products C1rs-C1-inhibitor complexes, C4bc, C3bc, C3bBbP and the terminal complement complex (TCC). No significant inter-group difference was found in any parameters, except for the concentration of TCC which was moderately lower in the PMEA group at termination of CPB. Complement activation during open-heart surgery was mainly mediated through the alternative pathway. In conclusion, PMEA-and Phisio-coated circuits displayed similar biocompatibility with respect to inflammatory and haemostatic responses during and after open-heart surgery.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 4 条
  • [1] Comparable biocompatibility of Phisio- and Bioline-coated cardiopulmonary bypass circuits indicated by the inflammatory response
    Thiara, A. S.
    Andersen, V. Y.
    Videm, V.
    Mollnes, T. E.
    Svennevig, K.
    Hoel, T. N.
    Fiane, A. E.
    PERFUSION-UK, 2010, 25 (01): : 9 - 16
  • [2] A prospective randomized trial comparing the clinical effectiveness and biocompatibility of heparin-coated circuits and PMEA-coated circuits in pediatric cardiopulmonary bypass
    Itoh, Hideshi
    Ichiba, Shingo
    Ujike, Yoshihito
    Douguchi, Takuma
    Kasahara, Shingo
    Arai, Sadahiko
    Sano, Shunji
    PERFUSION-UK, 2016, 31 (03): : 247 - 254
  • [3] Heparin-coated cardiopulmonary bypass circuits reduce circulating complement factors and interleukin-6 in paediatric heart surgery
    Olsson, C
    Siegbahn, A
    Henze, A
    Nilsson, B
    Venge, P
    Joachimsson, PO
    Thelin, S
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2000, 34 (01) : 33 - 40
  • [4] Changes in adhesion molecule expression and oxidative burst activity of granulocytes and monocytes during open-heart surgery with cardiopulmonary bypass compared with abdominal surgery
    Toft, P
    Nielsen, CH
    Tonnesen, E
    Hansen, TG
    Hokland, M
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1998, 15 (03) : 345 - 353