Comparison of lung volume measurements by antero-posterior chest X-ray and the SF6 washout technique in mechanically ventilated infants

被引:0
作者
Thome, U
Töpfer, A
Schaller, P
Pohlandt, F [1 ]
机构
[1] Univ Ulm, Childrens Hosp, Div Neonatol & Pediat Crit Care, D-82075 Ulm, Germany
[2] Tech Univ Dresden, Dept Pediat, D-8027 Dresden, Germany
关键词
chest roentgenogram; lung volume; functional residual capacity; sulfur hexafluoride washout technique; mechanical ventilation; newborn infants;
D O I
10.1002/(SICI)1099-0496(199810)26:4<265::AID-PPUL6>3.0.CO;2-G
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
While anterior/posterior chest x-rays (CXR) are routinely performed to estimate lung volume (LV) and adjust ventilator settings, the precise measurement of LV requires additional sophistication. In 31 infants ventilated because of surfactant deficiency (n = 23), bronchopulmonary dysplasia (n = 7), or pulmonary hypoplasia (n = 1) with either intermittent positive pressure (n = 18) or high frequency oscillation (n = 13) (gestational age 23-39 weeks (median 26 weeks); birthweight 550-2780 g (median 840 g); age at measurement 1-91 days (median 6 days); weight at study time (WST) 675-3000 g (median 938 g)), we investigated whether LV, as measured by the sulfur hexafluoride (SF6) washout technique, could by estimated from CXR by: 1) the sum (A+B) of the right (A) and left (B) lung fields areas; 2) the product (LxW) of the distances from the right apex to the right costophrenic angle (L) and between both costophrenic angles (W); 3) the diaphragm position relative to the posterior parts of the ribs (DP); and 4) the lung radiolucency (RL, grades 0-4). Correlations between A+B (r = 0.44) or LxW (r = 0.37) and LV were poor, but improved when A+B, LxW, and LV were normalized to WST: (A+B)/WST vs. LV/WST (r = 0.74), and LxW/WST vs. LV/WST (r = 0.67). DP (r = 0.13) and RL (Spearman's rho = 0.17) did not correlate with LV/WST. A multiple linear regression analysis led to the following best-fit equation: LV/WST = 2.58 (A+B)/WST - 5.47 DP + 42.2 (r = 0.83). We concluded that an estimate of LV from CXR lacked sufficient accuracy. DP and RL did not correlate with LV measured by SF, washout. Pediatr Pulmonol, 1998; 26:265-272, (C) 1998 Wiley-Liss, Inc.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 39 条
[1]   ROENTGENOGRAPHIC DETERMINATION OF TOTAL LUNG CAPACITY - A NEW METHOD EVALUATED IN HEALTH, EMPHYSEMA AND CONGESTIVE HEART FAILURE [J].
BARNHARD, HJ ;
PIERCE, JA ;
JOYCE, JW ;
BATES, JH .
AMERICAN JOURNAL OF MEDICINE, 1960, 28 (01) :51-60
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   ESTIMATION OF TOTAL LUNG CAPACITY BY PLANIMETRY OF CHEST RADIOGRAPHS IN CHILDREN 5 TO 10 YEARS OF AGE [J].
CAMPBELL, SC .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 127 (01) :106-107
[4]   SOLUBILITY OF INERT GASES IN HUMAN LUNG TISSUE [J].
CANDER, L .
JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (04) :538-540
[5]   Controversies in high-frequency ventilation [J].
Clark, RH ;
Gerstmann, DR .
CLINICS IN PERINATOLOGY, 1998, 25 (01) :113-+
[6]  
CLARK RH, 1992, PEDIATRICS, V89, P5
[7]   PEEP AND CPAP [J].
DUNCAN, AW ;
OH, TE ;
HILLMAN, DR .
ANAESTHESIA AND INTENSIVE CARE, 1986, 14 (03) :236-250
[8]  
East T D, 1987, J Clin Monit, V3, P14, DOI 10.1007/BF00770877
[9]   AUTOMATED SULFUR-HEXAFLUORIDE WASHOUT FUNCTIONAL RESIDUAL CAPACITY MEASUREMENT SYSTEM FOR ANY MODE OF MECHANICAL VENTILATION AS WELL AS SPONTANEOUS RESPIRATION [J].
EAST, TD ;
WORTELBOER, PJM ;
VANARK, E ;
BLOEM, FH ;
PENG, L ;
PACE, NL ;
CRAPO, RO ;
DREWS, D ;
CLEMMER, TP .
CRITICAL CARE MEDICINE, 1990, 18 (01) :84-91
[10]  
FROESE AB, 1987, AM REV RESPIR DIS, V135, P1363, DOI 10.1007/BF03009896