Left Ventricular Filling Pressures Contribute to Exercise Limitation in Patients with Continuous Flow Left Ventricular Assist Devices

被引:5
|
作者
Koshy, Aaron [1 ]
Bouzas-Cruz, Noelia [1 ,2 ]
Okwose, Nduka C. [3 ]
Fernandez, Oscar Gonzalez [1 ]
Green, Thomas [1 ]
Woods, Andrew [1 ]
Robinson-Smith, Nicola [1 ]
Tovey, Sian [1 ]
McDiarmid, Adam [1 ]
Parry, Gareth [1 ]
Schueler, Stephan [1 ]
Jakovljevic, Djordje G. [3 ]
MacGowan, Guy A. [1 ,3 ]
机构
[1] Freeman Rd Hosp, Dept Cardiol & Cardiothorac Surg, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Santiago Compostela, Galicia, Spain
[3] Newcastle Univ, Inst Cellular Med & Genet Med, Newcastle Upon Tyne, Tyne & Wear, England
关键词
exercise capacity; left ventricular assist device; hemodynamics; PUMP SPEED; CARDIAC-OUTPUT; HEART-FAILURE; DOUBLE-BLIND; IMPACT; PERFORMANCE; AFTERLOAD; PRELOAD; SUPPORT;
D O I
10.1097/MAT.0000000000001073
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We sought to determine hemodynamic mechanisms of exercise intolerance in a group of patients with the HeartWare ventricular assist device (VAD) compared to a group of heart failure patients. Twenty VAD and 22 heart failure patients underwent symptom-limited active straight leg raising exercise during right heart catheterization with thermodilution (TD), and upright cycling cardiopulmonary stress testing with cardiac output measurement by inert gas rebreathing (IGR) method. The TD and IGR exercise cardiac indexes were higher in VAD compared with heart failure group (both P < 0.05), although there was only a borderline increase in peak exercise oxygen consumption (VO2) (P = 0.06). Baseline and exercise right heart catheterization pressures were not significantly different between the two groups. The only significant independent predictors of peak VO2 in the heart failure group were exercise heart rate and cardiac index (both P < 0.05). In contrast, for the VAD group only, resting pulmonary arterial wedge and pulmonary arterial mean pressures were independently related to peak VO2 (both P < 0.05). Thus, in heart failure, exercise cardiac index is an important limitation to exercise capacity, and VADs increase exercise cardiac index. However, in VAD patients, this only produces limited benefits as increased pulmonary and pulmonary wedge pressures limit increases in exercise capacity.
引用
收藏
页码:247 / 252
页数:6
相关论文
共 50 条
  • [31] Continuous flow centrifugal left ventricular assist devices in patients with hypertrophic cardiomyopathy
    Muthiah, K.
    Robson, D.
    Macdonald, P.
    Keogh, A.
    Kotlyar, E.
    Spratt, P.
    Dhital, K.
    Granger, E.
    Jansz, P.
    Hayward, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 507 - 507
  • [32] Characteristics of the Electrocardiogram in Patients with Continuous-Flow Left Ventricular Assist Devices
    Martinez, Sara C.
    Fansler, Derrick
    Lau, Jeffrey
    Novak, Eric L.
    Joseph, Susan M.
    Kleiger, Robert E.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2015, 20 (01) : 62 - 68
  • [33] Endothelial Function in Patients With Continuous-Flow Left Ventricular Assist Devices
    Poredos, Pavel
    Jezovnik, Mateja K.
    Radovancevic, Rajko
    Gregoric, Igor D.
    ANGIOLOGY, 2021, 72 (01) : 9 - 15
  • [34] Predictors of Gastrointestinal Bleeding in Patients with Continuous Flow Left Ventricular Assist Devices
    Patel, S. R.
    Bello, R.
    Jooyoung, S. J.
    Stevens, G.
    Edwards, P.
    D'Alessandro, D.
    Simon, M.
    Goldstein, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : S94 - S94
  • [35] PERSISTENT MITRAL REGURGITATION IN PATIENTS WITH CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICES
    Chaisson, Jordan
    Kalathiya, Rohan
    Tedford, Ryan
    Stevens, Gerin
    Whitman, Glenn
    Sciortino, Chris
    Shah, Ashish
    Russell, Stuart
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A880 - A880
  • [36] Novel Oral Anticoagulants in Patients with Continuous Flow Left Ventricular Assist Devices
    Parikh, V.
    Parikh, U.
    Ramirez, A. M.
    Lamba, H.
    George, J.
    Fedson, S.
    Cheema, F.
    Civitello, A.
    Nair, A.
    Shafii, A.
    Loor, G.
    Rosengart, T.
    Frazier, O.
    Morgan, J.
    Delgado, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S425 - S425
  • [37] Endocrine Challenges in Patients with Continuous-Flow Left Ventricular Assist Devices
    Martucci, Gennaro
    Pappalardo, Federico
    Subramanian, Harikesh
    Ingoglia, Giulia
    Conoscenti, Elena
    Arcadipane, Antonio
    NUTRIENTS, 2021, 13 (03) : 1 - 17
  • [38] Ventricular Arrhythmia Prevalence and Burden in Patients With Third Generation Continuous Flow Left Ventricular Assist Devices
    Tabaja, Chadi
    Arwa, Younis
    Taigen, Tyler
    Lee, Justin
    Chung, Mina K.
    Barnard, John
    Nakhla, Shady
    Bhargava, Mandeep
    Higuchi, Koji
    Kanj, Mohamed H.
    Sroubek, Jakub
    Saliba, Walid I.
    CIRCULATION, 2023, 148
  • [39] Ventricular reconditioning and pump explantation in patients supported by continuous-flow left ventricular assist devices
    Frazier, O. H.
    Baldwin, Andrew C. W.
    Demirozu, Zumrut T.
    Segura, Ana Maria
    Hernandez, Ruben
    Taegtmeyer, Heinrich
    Mallidi, Hari
    Cohn, William E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (06): : 766 - 772
  • [40] Ventricular arrhythmias do not affect prognosis in patients with continuous-flow left ventricular assist devices
    Koenig, T.
    Heimeshoff, J.
    Duncker, D.
    Schmitto, J.
    Veltmann, C.
    EUROPEAN HEART JOURNAL, 2017, 38 : 234 - 234