Separation of charge variants of a monoclonal antibody by overloaded ion exchange chromatography

被引:10
作者
Baran, Krystian [1 ]
Zimoch, Patrycja [2 ]
Stanczak, Artur [3 ]
Piatkowski, Wojciech [1 ]
Antos, Dorota [1 ]
机构
[1] Rzeszow Univ Technol, Dept Chem & Proc Engn, Rzeszow, Poland
[2] Rzeszow Univ Technol, Doctoral Sch Engn & Tech Sci, Rzeszow, Poland
[3] Polpharma Biol, Gdansk, Poland
关键词
pH gradient; Mathematical modelling; Monoclonal antibody; Variant separation; EXCLUDED SURFACE-AREA; PH GRADIENTS; PROTEIN; HETEROGENEITY; PERFORMANCE; AGGREGATION; ADSORPTION; PHARMACOKINETICS; PURIFICATION; COLUMNS;
D O I
10.1016/j.chroma.2021.462607
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure for adjusting the content of charge variants of monoclonal antibody by ion exchange chromatography has been developed. The band splitting phenomenon was utilized to split the protein load into two parts, i.e., the flowthrough and bound fractions, which were either enriched or depleted with some of variants. The phenomenon was triggered by thermodynamic effects resulting from oversaturation of the resin binding sites at high column loadings as well as from kinetic effects arising from limited rates of mass transport. Cation exchange chromatography (CEX) and anion exchange chromatography (AEX) separations were examined, with the reverse order of the variant elution: acidic, main, basic in CEX, and basic, main, acidic in AEX, and the corresponding reverse enrichment tendency in the collected fractions. The separations were performed by pH gradient, whose course was simplified to two stages: isocratic loading and washing at mild pH to load and partly elute the protein, followed by a rapid pH change towards non-binding conditions to desorb the remains of the protein load. To improve yield of the operation, possibility of recycling of waste fractions was considered. To predict the process performance, a dynamic model was developed, which accounted for both adsorption kinetics and thermodynamics. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 58 条
[51]   Modeling of salt and pH gradient elution in ion-exchange chromatography [J].
Schmidt, Michael ;
Hafner, Mathias ;
Frech, Christian .
JOURNAL OF SEPARATION SCIENCE, 2014, 37 (1-2) :5-13
[52]   Recent advances in large-scale production of monoclonal antibodies and related proteins [J].
Shukla, Abhinav A. ;
Thoemmes, Joerg .
TRENDS IN BIOTECHNOLOGY, 2010, 28 (05) :253-261
[53]   A high-throughput method for fast detecting unfolding of monoclonal antibodies on cation exchange resins [J].
Stanczak, Artur ;
Baran, Krystian ;
Antos, Dorota .
JOURNAL OF CHROMATOGRAPHY A, 2020, 1634
[54]   Separation of oxidized variants of a monoclonal antibody by anion-exchange [J].
Teshima, Glen ;
Li, Ming-Xiang ;
Danishmand, Rahima ;
Obi, Chidi ;
To, Robert ;
Huang, Carol ;
Kung, Jacob ;
Lahidji, Vafa ;
Freeberg, Joel ;
Thorner, Lauren ;
Tomic, Milan .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (15) :2091-2097
[55]   Biopharmaceutical benchmarks 2014 [J].
Walsh, Gary .
NATURE BIOTECHNOLOGY, 2014, 32 (10) :992-1000
[56]   Protein variant separations by cation-exchange chromatography on tentacle-type polymeric stationary phases [J].
Weitzhandler, M ;
Farnan, D ;
Horvath, J ;
Rohrer, JS ;
Slingsby, RW ;
Avdalovic, N ;
Pohl, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :365-372
[57]   Improving pH gradient cation-exchange chromatography of monoclonal antibodies by controlling ionic strength [J].
Zhang, Liangyi ;
Patapoff, Thomas ;
Farnan, Dell ;
Zhang, Boyan .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1272 :56-64
[58]   Isolation and characterization of therapeutic antibody charge variants using cation exchange displacement chromatography [J].
Zhang, Taylor ;
Bourret, Justin ;
Cano, Tony .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) :5079-5086