Reduction of excitation light leakage to improve near-infrared fluorescence imaging for tissue surface and deep tissue imaging

被引:35
作者
Zhu, Banghe [1 ]
Rasmussen, John C. [1 ]
Lu, Yujie [1 ]
Sevick-Muraca, Eva M. [1 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, Ctr Mol Imaging, Brown Fdn Inst Mol Med, Houston, TX 77030 USA
关键词
optical imaging; optical filter; molecular imaging; fluorescence; noise floor;
D O I
10.1118/1.3497153
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Fluorescence-enhanced optical imaging using near-infrared (NIR) light developed for in vivo molecular targeting and reporting of various diseases provides promising opportunities for diagnostic imaging. However, the measurement sensitivity of NIR fluorescence (NIRF) optical imaging systems is limited by the leakage of the strong backscattered excitation light through rejection filters. In this article, the authors present a systematic method for improving sensitivity and validating the NIRF optical imager currently used for clinical imaging of human lymphatic function. Methods: The proposed systemic method consists of an appropriate filter combination and a collimation optics adapted to an NIRF optical imager. The spectral contributions were first assessed due to the excitation light backscattered from the tissue and from non-normal-incidence of the excitation light on the optical filters used in the authors' NIRF clinical imaging system. Then two tests were conducted to assess the system with and without the components of appropriate filters combination and collimation optics using: (1) a phantom to evaluate excitation light leakage as a function of target depth and (2) deployment in an actual human study. Results: The phantom studies demonstrate as much as two to three orders of magnitude reduction in the transmission ratio, indicating that the excitation light leakage can be reduced upon using the appropriate filter combination and collimation optics while an in vivo investigatory human study confirms improved imaging. Conclusions: The method for reducing the excitation light leakage is presented for validating collected signals for fluorescence imaging. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3497153]
引用
收藏
页码:5961 / 5970
页数:10
相关论文
共 16 条
  • [1] Near-infrared phase cancellation instrument for fast and accurate localization of fluorescent heterogeneity
    Chen, Y
    Mu, CP
    Intes, X
    Blessington, D
    Chance, B
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (07) : 3466 - 3473
  • [2] DOBROWOLSKI JA, 2009, HDB OPTICS OPTICAL P, V4
  • [3] Noise performance comparison of ICCD with CCD and EMCCD cameras
    Dussault, D
    Hoess, P
    [J]. INFRARED SYSTEMS AND PHOTELECTRONIC TECHNOLOGY, 2004, 5563 : 195 - 204
  • [4] Near-infrared fluorescence: application to in vivo molecular imaging
    Hilderbrand, Scott A.
    Weissleder, Ralph
    [J]. CURRENT OPINION IN CHEMICAL BIOLOGY, 2010, 14 (01) : 71 - 79
  • [5] Houston JP, 2003, PHOTOCHEM PHOTOBIOL, V77, P420, DOI 10.1562/0031-8655(2003)077<0420:SADPOC>2.0.CO
  • [6] 2
  • [7] Influence of excitation light rejection on forward model mismatch in optical tomography
    Hwang, K.
    Pan, T.
    Joshi, A.
    Rasmussen, J. C.
    Bangerth, W.
    Sevick-Muraca, E. M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (22) : 5889 - 5902
  • [8] Hwang K, 2005, MOL IMAGING, V4, P194
  • [9] DIFFUSION OF LIGHT IN TURBID MATERIAL
    ISHIMARU, A
    [J]. APPLIED OPTICS, 1989, 28 (12): : 2210 - 2215
  • [10] Marshall Milton V, 2010, Open Surg Oncol J, V2, P12