High-Flux versus High-Retention-Onset Membranes: In vivo Small and Middle Molecules Kinetics in Convective Dialysis Modalities

被引:12
作者
Cordeiro, Isis S. F. [1 ]
Cordeiro, Lilian [1 ]
Wagner, Carolina S. [1 ]
Araujo, Luiza Karla R. P. [1 ]
Pereira, Benedito J. [1 ,2 ]
Abensur, Hugo [1 ]
Elias, Rosilene M. [1 ,2 ]
Silva, Bruno C. [1 ]
机构
[1] Univ Sao Paulo, Hosp Clin HCFMUSP, Dept Med, Renal Div, Rua Dr Eneas Carvalho Aguiar 255,7th Floor, BR-05403000 Sao Paulo, SP, Brazil
[2] Univ Nove Julho UNINOVE, Nephrol Div, Sao Paulo, Brazil
关键词
Beta-2; microglobulin; Clearance; Hemodiafiltration; Uremic toxins; Dialysis membrane; Hemodialysis; C-REACTIVE PROTEIN; ONLINE HEMODIAFILTRATION; BETA-2-MICROGLOBULIN REMOVAL; SERUM BETA-2-MICROGLOBULIN; CARDIOVASCULAR-DISEASE; EXPANDED HEMODIALYSIS; BETA(2)-MICROGLOBULIN; INFLAMMATION; MORTALITY; INTERLEUKIN-6;
D O I
10.1159/000502082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients undergoing maintenance hemodialysis (HD) exhibit increased levels of uremic toxins, which are associated with poor outcomes. Recently, new dialysis membranes have allowed clearance of solutes with higher molecular weight, without significant albumin losses high-retention-onset-HD (HRO-HD). Methods: Prospective crossover trial, in which 16 prevalent patients switched from high-flux HD (HF-HD) to online hemodiafiltration (olHDF) and HRO-HD for 4 weeks. The following variables were evaluated: pre- and post-dialysis serum concentrations of albumin, urea, phosphate (P), beta-2 microglobulin (beta M-2), and total mass (TM) extraction and dialyzer clearance of urea, P, and beta M-2. Results: Comparing HF-HD, olHDF, and HRO-HD, respectively, there were no differences regarding pre-dialysis serum concentrations of albumin (3.94 +/- 0.36, 4.06 +/- 0.22, and 3.93 +/- 0.41 g/dL, p = 0.495), urea (166 +/- 29, 167 +/- 30, and 164 +/- 27 mg/dL, p = 0.971), P (4.9 +/- 2.1, 5.2 +/- 1.6, and 4.9 +/- 2.1 mg/dL, p = 0.879), and beta M-2 (31.3 +/- 7.1, 32.6 +/- 8.6, and 33.7 +/- 5.9 mu g/mL, p = 0.646). beta M-2 clearance was significantly lower in HF-HD in comparison to both olHDF and HRO-HD: 43 (37-53) versus 64 (48-85) mL/min, p = 0.013, and 69 (58-86) mL/min, p = 0.015, respectively. Post-dialysis beta M-2 serum concentration was higher in HF-HD in comparison to olHDF and HRO-HD: 11.6 (9.6-12.4) vs. 5.7 (4.5-7.0) mu g/mL, p = 0.001, and 5.6 (5.3-7.6) mu g/mL, p = 0.001, respectively. TM extraction of urea, P, and beta M-2 were similar across the 3 dialysis modalities. Conclusions: olHDF and HRO-HD were superior to HF-HD regarding beta M-2 clearance, leading to lower post-dialysis beta M-2 levels.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 40 条
[1]   Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement [J].
Argiles, A ;
Ficheux, A ;
Thomas, M ;
Bosc, JY ;
Kerr, PG ;
Lorho, R ;
Flavier, JL ;
Stec, F ;
Adele, C ;
Leblanc, M ;
Garred, LJ ;
Canaud, B ;
Mion, H ;
Mion, CM .
KIDNEY INTERNATIONAL, 1997, 52 (02) :530-537
[2]   Predictors of early mortality among incident US hemodialysis patients in the Dialysis Outcomes and Practice Patterns Study (DOPPS) [J].
Bradbury, Brian D. ;
Fissell, Rachel B. ;
Albert, Justin M. ;
Anthony, Mary S. ;
Critchlow, Cathy W. ;
Pisoni, Ronald L. ;
Port, Friedrich K. ;
Gillespie, Brenda W. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 2 (01) :89-99
[3]  
Canaud Bernard, 2012, Nephrourol Mon, V4, P519, DOI 10.5812/numonthly.3060
[4]   Inflammation in End-Stage Renal Disease-What Have We Learned in 10 Years? [J].
Carrero, Juan J. ;
Stenvinkel, Peter .
SEMINARS IN DIALYSIS, 2010, 23 (05) :498-509
[5]   Kinetics of 131I-β2 microglobulin in hemodialysis patients:: Assessment using total body counting [J].
Chanard, J ;
Caudwell, V ;
Valeire, J ;
Vincent, C ;
Randoux, C ;
Wuillai, A ;
Wynckel, A .
ARTIFICIAL ORGANS, 1998, 22 (07) :574-580
[6]   Serum β-2 microglobulin levels predict mortality in dialysis patients:: Results of the HEMO study [J].
Cheung, Alfred K. ;
Rocco, Michael V. ;
Yan, Guofen ;
Leypoldt, John K. ;
Levin, Nathan W. ;
Greene, Tom ;
Agodoa, Lawrence ;
Bailey, James ;
Beck, Gerald J. ;
Clark, William ;
Levey, Andrew S. ;
Ornt, Daniel B. ;
Schulman, Gerald ;
Schwab, Steven ;
Teehan, Brendan ;
Eknoyan, Garabed .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 17 (02) :546-555
[7]  
DAUGIRDAS JT, 1993, J AM SOC NEPHROL, V4, P1205
[8]   BETA-2-MICROGLOBULIN KINETICS IN MAINTENANCE HEMODIALYSIS - A COMPARISON OF CONVENTIONAL AND HIGH-FLUX DIALYZERS AND THE EFFECTS OF DIALYZER REUSE [J].
DIRAIMONDO, CR ;
POLLAK, VE .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1989, 13 (05) :390-395
[9]   Superior dialytic clearance of β2-microglobulin and p-cresol by high-flux hemodialysis as compared to peritoneal dialysis [J].
Evenepoel, P. ;
Bammens, B. ;
Verbeke, K. ;
Vanrenterghem, Y. .
KIDNEY INTERNATIONAL, 2006, 70 (04) :794-799
[10]  
Hoenich NA, 1996, J AM SOC NEPHROL, V7, P871