Corneal Astigmatism Stability in Descemet Membrane Endothelial Keratoplasty for Fuchs Corneal Dystrophy

被引:18
作者
Yokogawa, Hideaki [1 ,2 ]
Sanchez, P. James [1 ]
Mayko, Zachary M. [3 ]
Straiko, Michael D. [1 ]
Terry, Mark A. [1 ]
机构
[1] Devers Eye Inst, Cornea Serv, Portland, OR USA
[2] Kanazawa Univ, Dept Ophthalmol, Grad Sch Med Sci, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
[3] Lions VisionGift, Portland, OR USA
关键词
Descemet membrane endothelial keratoplasty; corneal astigmatism; surgically induced astigmatism; REFRACTIVE CHANGE; PHACOEMULSIFICATION; INJECTOR; OUTCOMES; EYES;
D O I
10.1097/ICO.0000000000000882
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To calculate the magnitude and angle of the shift in corneal astigmatism associated with Descemet membrane endothelial keratoplasty (DMEK) surgery to determine the feasibility of concurrent astigmatism correction at the time of DMEK triple procedures.Design:Retrospective study.Methods:Forty-seven eyes that previously underwent the DMEK procedure for Fuchs endothelial corneal dystrophy and that had more than 1.0 diopter (D) of front corneal astigmatism preoperatively were identified. All DMEK surgeries used a clear corneal temporal incision of 3.2 mm. Surgically induced astigmatism (SIA) was evaluated 6 months postsurgery with vector analysis using Scheimpflug image reading.Results:We did not find a difference between pre- and postoperative magnitude of front astigmatism (P = 0.88; paired t test). The magnitude of the SIA front surface was 0.77 0.63 D (range, 0.10-3.14 D). The centroid vector of the SIA front surface was 0.14 at 89.3 degrees. A hyperopic corneal power shift was noted in both the front surface by 0.26 +/- 0.74 D (range, 0.45-3.05 D) (P = 0.018; paired t test) and back surface by 0.56 +/- 0.55 D (range, 0.25-2.40 D) (P < 0.01; paired t test).Conclusions:DMEK surgery induces minimal amounts of corneal astigmatism that is a with-the-rule shift associated with a temporal clear corneal incision. The stability of these data from preop to postop supports the plausibility of incorporating astigmatism correction with the cautious use of toric intraocular lenses for patients with Fuchs corneal dystrophy and cataract.
引用
收藏
页码:932 / 937
页数:6
相关论文
共 30 条
  • [11] Huang D, 1999, J REFRACT SURG, V15, P538
  • [12] Kanellopoulos A John, 2014, Cornea, V33, P340, DOI 10.1097/ICO.0000000000000053
  • [13] In Vivo Laser Confocal Microscopy after Descemet's Membrane Endothelial Keratoplasty
    Kobayashi, Akira
    Yokogawa, Hideaki
    Yamazaki, Natsuko
    Masaki, Toshinori
    Sugiyama, Kazuhisa
    [J]. OPHTHALMOLOGY, 2013, 120 (05) : 923 - 930
  • [14] Correcting astigmatism with toric intraocular lenses: Effect of posterior corneal astigmatism
    Koch, Douglas D.
    Jenkins, Richard B.
    Weikert, Mitchell P.
    Yeu, Elizabeth
    Wang, Li
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12) : 1803 - 1809
  • [15] Contribution of posterior corneal astigmatism to total corneal astigmatism
    Koch, Douglas D.
    Ali, Shazia F.
    Weikert, Mitchell P.
    Shirayama, Mariko
    Jenkins, Richard
    Wang, Li
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) : 2080 - 2087
  • [16] Pentacam Characterization of Corneas With Fuchs Dystrophy Treated With Descemet Membrane Endothelial Keratoplasty
    Kwon, Robert O.
    Price, Marianne O.
    Price, Francis W., Jr.
    Ambrosio, Renato, Jr.
    Belin, Michael W.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (12) : 972 - 979
  • [17] Descemet Membrane Endothelial Keratoplasty Combined With Phacoemulsification and Intraocular Lens Implantation: Advanced Triple Procedure
    Laaser, Kathrin
    Bachmann, Bjoern O.
    Horn, Folkert K.
    Cursiefen, Claus
    Kruse, Friedrich E.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (01) : 47 - 55
  • [18] Superior Versus Temporal Approach in Descemet Membrane Endothelial Keratoplasty
    Maier, Anna-Karina B.
    Gundlach, Enken
    Gonnermann, Johannes
    Klamann, Matthias K. J.
    Joussen, Antonia M.
    Bertelmann, Eckart
    Torun, Necip
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (01) : 111 - 117
  • [19] Induced Astigmatism With 2.2-and 3.0-mm Coaxial Phacoemulsification Incisions
    Masket, Samuel
    Wang, Li
    Belani, Shaleen
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (01) : 21 - 24
  • [20] Melles GRJ, 2006, CORNEA, V25, P987, DOI 10.1097/01.ico.0000248385.16896.34