New laser technologies in ophthalmology for normalisation of intraocular pressure and correction of refraction

被引:9
|
作者
Baum, O. I. [1 ]
Yuzhakov, A. V. [1 ]
Bolshunov, A. V. [2 ]
Siplivyi, V. I. [2 ]
Khomchik, O. V. [2 ]
Zheltov, G. I. [3 ]
Sobol, E. N. [1 ]
机构
[1] Russian Acad Sci, Inst Photon Technol, Fed Sci Res Ctr Crystallog & Photon, Leninsky Prosp 59, Moscow 119333, Russia
[2] Fed State Budgetary Sci Inst, Sci Res Inst Eye Dis, Ul Rossolimo 11A, Moscow 119021, Russia
[3] Natl Acad Sci Belarus, BI Stepanov Inst Phys, Prosp Nezavisimosti 68, Minsk 220072, BELARUS
基金
俄罗斯基础研究基金会;
关键词
laser; glaucoma; refraction; thermotensions; optical methods; structural changes; CORNEA; SCLERA; TISSUE;
D O I
10.1070/QEL16368
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the results of recent studies that develop principally new approaches to solving the problem of visual impairment and provide the basis for new laser technologies in ophthalmology for the treatment of glaucoma, myopia and hypermetropia. The considered theoretical models and optical methods for detecting laser-induced structural changes in eye tissues pave the way to the invention of control systems with feedback, providing efficient and safe laser treatment.
引用
收藏
页码:860 / 866
页数:7
相关论文
共 50 条
  • [21] A new rebound tonometer for home monitoring of intraocular pressure
    Rosentreter, Andre
    Jablonski, Kerstin S.
    Mellein, Anne C.
    Gaki, Stergiani
    Hueber, Arno
    Dietlein, Thomas S.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (11) : 1713 - 1719
  • [22] Construction, calibration and results of a new sensor in an intraocular lens with telemetric transmission of the intraocular pressure
    Hille, K
    Draeger, J
    Eggers, T
    Stegmaier, P
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (05) : 376 - 380
  • [23] Correction methods for noncontact intraocular pressure measurement in patients with keratoconus and healthy individuals
    Alvani, Azam
    Hashemi, Hassan
    Pakravan, Mohammad
    Yaseri, Mehdi
    Jafarzadehpur, Ebrahim
    Fotouhi, Akbar
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2022, 85 (05) : 490 - 497
  • [24] Smoothing the Intraocular Pressure Roller Coaster: A New Goal?
    Katz, L. Jay
    Myers, Jonathan S.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 177 - 178
  • [25] A new rebound tonometer for home monitoring of intraocular pressure
    André Rosentreter
    Kerstin S. Jablonski
    Anne C. Mellein
    Stergiani Gaki
    Arno Hueber
    Thomas S. Dietlein
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 1713 - 1719
  • [26] Intraocular pressure control and fluctuation: the effect of treatment with selective laser trabeculoplasty
    Nagar, M.
    Luhishi, E.
    Shah, N.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (04) : 497 - 501
  • [27] Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
    Iglesias, Maria
    Kudsieh, Bachar
    Laiseca, Andrea
    Santos, Cristina
    Nadal, Jeroni
    Barraquer, Rafael
    Casaroli-Marano, Ricardo P.
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [28] Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
    María Iglesias
    Bachar Kudsieh
    Andrea Laiseca
    Cristina Santos
    Jeroni Nadal
    Rafael Barraquer
    Ricardo P. Casaroli-Marano
    BMC Ophthalmology, 22
  • [29] New method for remote and repeatable monitoring of intraocular pressure variations
    Margalit, Israel
    Beiderman, Yevgeny
    Skaat, Alon
    Rosenfeld, Elkanah
    Belkin, Michael
    Tornow, Ralf-Peter
    Mico, Vicente
    Garcia, Javier
    Zalevsky, Zeev
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (02)
  • [30] The Ahmed Glaucoma Valve - a new implant for high intraocular pressure
    Hille, K
    Ruprecht, KW