New laser technologies in ophthalmology for normalisation of intraocular pressure and correction of refraction

被引:9
|
作者
Baum, O. I. [1 ]
Yuzhakov, A. V. [1 ]
Bolshunov, A. V. [2 ]
Siplivyi, V. I. [2 ]
Khomchik, O. V. [2 ]
Zheltov, G. I. [3 ]
Sobol, E. N. [1 ]
机构
[1] Russian Acad Sci, Inst Photon Technol, Fed Sci Res Ctr Crystallog & Photon, Leninsky Prosp 59, Moscow 119333, Russia
[2] Fed State Budgetary Sci Inst, Sci Res Inst Eye Dis, Ul Rossolimo 11A, Moscow 119021, Russia
[3] Natl Acad Sci Belarus, BI Stepanov Inst Phys, Prosp Nezavisimosti 68, Minsk 220072, BELARUS
基金
俄罗斯基础研究基金会;
关键词
laser; glaucoma; refraction; thermotensions; optical methods; structural changes; CORNEA; SCLERA; TISSUE;
D O I
10.1070/QEL16368
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the results of recent studies that develop principally new approaches to solving the problem of visual impairment and provide the basis for new laser technologies in ophthalmology for the treatment of glaucoma, myopia and hypermetropia. The considered theoretical models and optical methods for detecting laser-induced structural changes in eye tissues pave the way to the invention of control systems with feedback, providing efficient and safe laser treatment.
引用
收藏
页码:860 / 866
页数:7
相关论文
共 50 条
  • [1] Effect of Nd:YAG laser posterior capsulotomy on intraocular pressure, refraction, anterior chamber depth, and macular thickness
    Parajuli, Anil
    Joshi, Purushottam
    Subedi, Prabha
    Pradhan, Chandni
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 945 - 952
  • [2] Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    Herndon, Leon W.
    CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (02) : 115 - 119
  • [3] Laser-assisted correction of eye cornea refraction with ring-shaped laser beam
    Baum, Olga
    Yuzhakov, Aleksey
    Omelchenko, Alexander
    Bolshunov, Andrey
    Siplivy, Vladimir
    Sobol, Emil
    MEDICAL LASER APPLICATIONS AND LASER-TISSUE INTERACTIONS VIII, 2017, 10417
  • [4] Advancements in Wearable and Implantable Intraocular Pressure Biosensors for Ophthalmology: A Comprehensive Review
    Wu, Kevin Y.
    Mina, Mina
    Carbonneau, Marjorie
    Marchand, Michael
    Tran, Simon D.
    MICROMACHINES, 2023, 14 (10)
  • [5] Correction of eye refraction by nonablative laser action on thermomechanical properties of cornea and sclera
    Sobol, EN
    Bolshunov, AV
    Vorobieva, NN
    Omel'chenko, AI
    Zakharkina, OL
    Ignat'eva, NY
    Grokhovskaya, TE
    Lunin, VV
    QUANTUM ELECTRONICS, 2002, 32 (10) : 909 - 912
  • [6] The effect of orbital decompression surgery on refraction and intraocular pressure in patients with thyroid orbitopathy
    Norris, J. H.
    Ross, J. J.
    Kazim, M.
    Selva, D.
    Malhotra, R.
    EYE, 2012, 26 (04) : 535 - 543
  • [7] The effect of orbital decompression surgery on refraction and intraocular pressure in patients with thyroid orbitopathy
    J H Norris
    J J Ross
    M Kazim
    D Selva
    R Malhotra
    Eye, 2012, 26 : 535 - 543
  • [8] Intraocular pressure after cyclophotocoagulation with the diode laser
    Flamm, C
    Wiegand, W
    OPHTHALMOLOGE, 2004, 101 (03): : 263 - 267
  • [9] Refraction, intraocular pressure and anterior chamber depth changes after Nd:YAG laser treatment for posterior capsular opacification in pseudophakic eyes
    Ozkurt, Yelda Buyru
    Sengor, Tomris
    Evciman, Tufan
    Haboglu, Melih
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (05) : 412 - 415
  • [10] INTRAOCULAR-PRESSURE - NEW PERSPECTIVES