High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient-Isotachophoresis

被引:146
作者
Busnel, Jean-Marc [1 ,2 ]
Schoenmaker, Bart [1 ]
Ramautar, Rawi [1 ]
Carrasco-Pancorbo, Alegria [1 ]
Ratnayake, Chitra [2 ]
Feitelson, Jerald S. [2 ]
Chapman, Jeff D. [2 ]
Deelder, Andre M. [1 ]
Mayboroda, Oleg A. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Parasitol, Biomol Mass Spectrometry Unit, Leiden, Netherlands
[2] Beckman Coulter Inc, Brea, CA 92822 USA
关键词
ZONE-ELECTROPHORESIS; FLOW; ESI; MS;
D O I
10.1021/ac102159d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sheathless interface making use of a porous tip has been used for coupling capillary electrophoresis and electrospray ionization mass spectrometry. First, effective flow rates using the interface have been characterized. It was found that the interface is capable of generating a stable spray with flow rates ranging from below 10 nL/min to >340 nL/min, enabling its use in either the mass or concentration-sensitive region of the electrospray process. Subsequently, by analyzing peptide mixtures of increasing complexity, we have demonstrated that this platform provides exquisite sensitivity enabling the detection of very low amounts of materials with very high resolving power. Transient isotachophoresis (t-ITP) can also be integrated with this setup to increase the mass loading of the system while maintaining peak efficiency and resolution. Concentration limits of detection in the subnanomolar or nanomolar range can be achieved with or without t-ITP, respectively. The application of a vacuum at the inlet of the separation capillary further allowed the peak capacity of the system to be improved while also enhancing its efficiency. As a final step in this study, it was demonstrated that the intrinsic properties of the interface allows the use of coated noncharged surfaces so that very high peak capacities can be achieved.
引用
收藏
页码:9476 / 9483
页数:8
相关论文
共 29 条
[1]   Glycosylation analysis of glycoproteins and proteoglycans using capillary electrophoresis-mass spectrometry strategies [J].
Amon, Sabine ;
Zamfir, Alina D. ;
Rizzi, Andreas .
ELECTROPHORESIS, 2008, 29 (12) :2485-2507
[2]   Glycoform characterization of erythropoietin combining glycan and intact protein analysis by capillary electrophoresis electrospray time-of-flight mass spectrometry [J].
Balaguer, Elvira ;
Demelbauer, Uwe ;
Pelzing, Matthias ;
Sanz-Nebot, Victoria ;
Barbosa, Jose ;
Neusuess, Christian .
ELECTROPHORESIS, 2006, 27 (13) :2638-2650
[3]   CAPILLARY ELECTROPHORESIS INSTRUMENTATION AS A BENCH-TOP VISCOMETER [J].
BELLO, MS ;
REZZONICO, R ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) :199-204
[4]   Iontophoretic Fraction Collection for Coupling Capillary Zone Electrophoresis with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry [J].
Busnel, Jean-Marc ;
Josserand, Jacques ;
Lion, Niels ;
Girault, Hubert H. .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3867-3872
[5]   Efficient and highly reproducible capillary electrophoresis-mass spectrometry of peptides using Polybrene-poly(vinyl sulfonate)-coated capillaries [J].
Catai, Jonatan R. ;
Torano, Javier Sastre ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
ELECTROPHORESIS, 2006, 27 (11) :2091-2099
[6]   EARLY PHASES OF THE DISPERSION OF A SAMPLE INJECTED IN POISEUILLE FLOW [J].
GOLAY, MJE ;
ATWOOD, JG .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :353-370
[7]   Capillary electrophoresis-mass spectrometry for the analysis of intact proteins [J].
Haselberg, Rob ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) :81-109
[8]   Relevance and use of capillary coatings in capillary electrophoresis-mass spectrometry [J].
Huhn, C. ;
Ramautar, R. ;
Wuhrer, M. ;
Somsen, G. W. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (01) :297-314
[9]   Capillary-based multi nanoelectrospray emitters: Improvements in ion transmission efficiency and implementation with capillary reversed-phase LC-ESI-MS [J].
Kelly, Ryan T. ;
Page, Jason S. ;
Zhao, Rui ;
Qian, Wei-Jun ;
Mottaz, Heather M. ;
Tang, Keqi ;
Smith, Richard D. .
ANALYTICAL CHEMISTRY, 2008, 80 (01) :143-149
[10]   EFFECT OF MULTIPLE SPRAYERS ON DYNAMIC-RANGE AND FLOW-RATE LIMITATIONS IN ELECTROSPRAY AND IONSPRAY MASS-SPECTROMETRY [J].
KOSTIAINEN, R ;
BRUINS, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (07) :549-558