Fault damage zone volume and initial salinity distribution determine intensity of shallow aquifer salinisation in subsurface storage

被引:17
作者
Tillner, Elena [1 ]
Langer, Maria [1 ]
Kempka, Thomas [1 ]
Kuehn, Michael [1 ,2 ]
机构
[1] GFZ German Res Ctr Geosci, D-14473 Potsdam, Germany
[2] Univ Potsdam, Inst Earth & Environm Sci, Karl Liebknecht Str 24-25, D-14476 Potsdam, Germany
关键词
CO2; STORAGE; BRINE MIGRATION; FLUID-FLOW; PRESSURE MANAGEMENT; DYNAMIC FLOW; PERMEABILITY; PRESSURIZATION; SEQUESTRATION; SIMULATIONS; INJECTION;
D O I
10.5194/hess-20-1049-2016
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Injection of fluids into deep saline aquifers causes a pore pressure increase in the storage formation, and thus displacement of resident brine. Via hydraulically conductive faults, brine may migrate upwards into shallower aquifers and lead to unwanted salinisation of potable groundwater resources. In the present study, we investigated different scenarios for a potential storage site in the Northeast German Basin using a three-dimensional (3-D) regional-scale model that includes four major fault zones. The focus was on assessing the impact of fault length and the effect of a secondary reservoir above the storage formation, as well as model boundary conditions and initial salinity distribution on the potential salinisation of shallow groundwater resources. We employed numerical simulations of brine injection as a representative fluid. Our simulation results demonstrate that the lateral model boundary settings and the effective fault damage zone volume have the greatest influence on pressure build-up and development within the reservoir, and thus intensity and duration of fluid flow through the faults. Higher vertical pressure gradients for short fault segments or a small effective fault damage zone volume result in the highest salinisation potential due to a larger vertical fault height affected by fluid displacement. Consequently, it has a strong impact on the degree of shallow aquifer salinisation, whether a gradient in salinity exists or the saltwater-freshwater interface lies below the fluid displacement depth in the faults. A small effective fault damage zone volume or low fault permeability further extend the duration of fluid flow, which can persist for several tens to hundreds of years, if the reservoir is laterally confined. Laterally open reservoir boundaries, large effective fault damage zone volumes and intermediate reservoirs significantly reduce vertical brine migration and the potential of freshwater salinisation because the origin depth of displaced brine is located only a few decametres below the shallow aquifer in maximum. The present study demonstrates that the existence of hydraulically conductive faults is not necessarily an exclusion criterion for potential injection sites, because salinisation of shallower aquifers strongly depends on initial salinity distribution, location of hydraulically conductive faults and their effective damage zone volumes as well as geological boundary conditions.
引用
收藏
页码:1049 / 1067
页数:19
相关论文
共 58 条
[1]  
[Anonymous], 2016, CARBON DIOXIDE CAPTU
[2]   Faults as conduit-barrier systems to fluid flow in siliciclastic sedimentary aquifers [J].
Bense, V. F. ;
Person, M. A. .
WATER RESOURCES RESEARCH, 2006, 42 (05)
[3]   Simultaneous CO2 injection and water production to optimise aquifer storage capacity [J].
Bergmo, Per Eirik S. ;
Grimstad, Alv-Arne ;
Lindeberg, Erik .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (03) :555-564
[4]  
Beutler G., 2012, Brandenburg. Geowiss. Beitr., V19, P93
[5]   Brine flow up a well caused by pressure perturbation from geologic carbon sequestration: Static and dynamic evaluations [J].
Birkholzer, Jens T. ;
Nicot, Jean Philippe ;
Oldenburg, Curtis M. ;
Zhou, Quanlin ;
Kraemer, Stephen ;
Bandilla, Karl .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (04) :850-861
[6]   Large-scale impact of CO2 storage in deep saline aquifers: A sensitivity study on pressure response in stratified systems [J].
Birkholzer, Jens T. ;
Zhou, Quanlin ;
Tsang, Chin-Fu .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2009, 3 (02) :181-194
[7]   Combining Brine Extraction, Desalination, and Residual-Brine Reinjection with CO2 Storage in Saline Formations: Implications for Pressure Management, Capacity, and Risk Mitigation [J].
Buscheck, Thomas A. ;
Sun, Yunwei ;
Hao, Yue ;
Wolery, Thomas J. ;
Bourcier, William ;
Tompson, Andrew F. B. ;
Jones, Edwin D. ;
Friedmann, S. Julio ;
Aines, Roger D. .
10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 :4283-4290
[8]  
Caine JS, 1996, GEOLOGY, V24, P1025, DOI 10.1130/0091-7613(1996)024<1025:FZAAPS>2.3.CO
[9]  
2
[10]   Modeling of coupled deformation and permeability evolution during fault reactivation induced by deep underground injection of CO2 [J].
Cappa, Frederic ;
Rutqvist, Jonny .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (02) :336-346