Successful endoscopic closure with an over-the-scope clip for sigmoid colon perforation due to bile duct stent migration

被引:4
作者
Yamaguchi, Daisuke [1 ,2 ]
Nagatsuma, Goshi [1 ]
Jinnouchi, Azuki [1 ]
Hara, Yumi [1 ]
Shimakura, Akane [1 ]
Jubashi, Amane [1 ]
Yoshioka, Wataru [1 ]
Tanaka, Yuichiro [1 ]
Hino, Naoyuki [1 ]
Ario, Keisuke [1 ]
Tsunada, Seiji [1 ]
机构
[1] Natl Hosp Org Ureshino, Med Ctr, Dept Gastroenterol, Ureshino, Japan
[2] Saga Univ, Dept Internal Med, Div Gastroenterol, Saga 8498501, Japan
关键词
Over-the-scope clip; Endoscopic closure; Bile duct stent; Stent migration; Stent perforation; BILIARY STENT; DUODENAL PERFORATION; RISK-FACTORS; EXPERIENCE; MANAGEMENT;
D O I
10.1007/s12328-021-01544-x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
An 86-year-old woman presented with a history of endoscopic papillary sphincterotomy for bile duct stones and diverticulitis. The patient was admitted as an emergency case of acute cholangitis due to choledocholithiasis, underwent endoscopic bile duct stenting, and was discharged with a plan for endoscopic lithotripsy. One month later, the patient was readmitted owing to abdominal pain. Abdominal computed tomography at admission showed that the bile duct stent had migrated to the sigmoid colon and the presence of a small amount of extraintestinal gas, suggesting a colonic perforation. Lower gastrointestinal endoscopy showed adhesions and intestinal stenosis in the sigmoid colon, probably after diverticulitis, and the bile duct stent that had perforated the same site. The stent was removed and endoscopic closure of the perforation was performed using an over-the-scope clip. Abdominal computed tomography 8 days after the closure showed no extraintestinal gas. The patient resumed eating and was discharged on the 14th day of admission. There was no recurrence of abdominal pain. Endoscopic closure of sigmoid colon perforation due to bile duct stent migration using an over-the-scope clip has not been reported thus far, and it may be a new treatment option in the future.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 21 条
[1]   Migration of biliary plastic stents: experience of a tertiary center [J].
Arhan, Mehmet ;
Oedemis, Buelent ;
Parlak, Erkan ;
Ertugrul, Ibrahim ;
Basar, Omer .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (04) :769-775
[2]   Outcome and management of endoscopic retrograde cholangiopancreatography perforations: A community perspective [J].
Bray, Mallory S. ;
Borgert, Andrew J. ;
Folkers, Milan E. ;
Kothari, Shanu N. .
AMERICAN JOURNAL OF SURGERY, 2017, 214 (01) :69-73
[3]   Lateral duodenal wall perforation due to plastic biliary stent migration: a case series of endoscopic closure [J].
Bureau, Marc-Andre ;
Gkolfakis, Paraskevas ;
Blero, Daniel ;
Pezzullo, Martina ;
Deviere, Jacques ;
Lemmers, Arnaud .
ENDOSCOPY INTERNATIONAL OPEN, 2020, 8 (05) :E573-E577
[4]   Remove the migrated stent: sigmoid colon perforation from migrated biliary stent [J].
Chittleborough, Timothy John ;
Mgaieth, Sara ;
Kirkby, Brian ;
Zakon, Joseph .
ANZ JOURNAL OF SURGERY, 2016, 86 (11) :947-+
[5]   A rare complication of ERCP: duodenal perforation due to biliary stent migration [J].
Gromski, Mark A. ;
Bick, Benjamin L. ;
Vega, David ;
Easler, Jeffrey J. ;
Watkins, James L. ;
Sherman, Stuart ;
Lehman, Glen A. ;
Fogel, Evan L. .
ENDOSCOPY INTERNATIONAL OPEN, 2020, 08 (11) :E1530-E1536
[6]   International multicenter experience with an over-the-scope clipping device for endoscopic management of GI defects (with video) [J].
Haito-Chavez, Yamile ;
Law, Joanna K. ;
Kratt, Thomas ;
Arezzo, Alberto ;
Verra, Mauro ;
Morino, Mario ;
Sharaiha, Reem Z. ;
Poley, Jan-Werner ;
Kahaleh, Michel ;
Thompson, Christopher C. ;
Ryan, Michele B. ;
Choksi, Neel ;
Elmunzer, B. Joseph ;
Gosain, Sonia ;
Goldberg, Eric M. ;
Modayil, Rani J. ;
Stavropoulos, Stavros N. ;
Schembre, Drew B. ;
DiMaio, Christopher J. ;
Chandrasekhara, Vinay ;
Hasan, Muhammad K. ;
Varadarajulu, Shyam ;
Hawes, Robert ;
Gomez, Victoria ;
Woodward, Timothy A. ;
Rubel-Cohen, Sergio ;
Fluxa, Fernando ;
Vleggaar, Frank P. ;
Akshintala, Venkata S. ;
Raju, Gottumukkala S. ;
Khashab, Mouen A. .
GASTROINTESTINAL ENDOSCOPY, 2014, 80 (04) :610-622
[7]   Migration of a biliary stent causing duodenal perforation and biliary peritonitis [J].
Issa, Hussain ;
Nahawi, Mamdouh ;
Bseiso, Bahaa ;
Al-Salem, Ahmed .
WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2013, 5 (10) :523-526
[8]   INCIDENCE AND RISK-FACTORS FOR BILIARY AND PANCREATIC STENT MIGRATION [J].
JOHANSON, JF ;
SCHMALZ, MJ ;
GEENEN, JE .
GASTROINTESTINAL ENDOSCOPY, 1992, 38 (03) :341-346
[9]   Risk factors for proximal migration of biliary tube stents [J].
Kawaguchi, Yoshiaki ;
Ogawa, Masami ;
Kawashima, Yohei ;
Mizukami, Hajime ;
Maruno, Atsuko ;
Ito, Hiroyuki ;
Mine, Tetsuya .
WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (05) :1318-1324
[10]   A new endoscopic over-the-scope clip system for treatment of lesions and bleeding in the GI tract:: first clinical experiences [J].
Kirschniak, Andreas ;
Kratt, Thomas ;
Stueker, Dietmar ;
Braun, Alexander ;
Schurr, Marc-Oliver ;
Koenigsrainer, Alfred .
GASTROINTESTINAL ENDOSCOPY, 2007, 66 (01) :162-167