Determination of Cotinine, 3′-Hydroxycotinine, and Their Glucuronides in Urine by Ultra-high Performance Liquid Chromatography

被引:4
|
作者
Shastri, Madhur D. [1 ]
Lu, Wenying [1 ]
Ferguson, Stuart G. [1 ,2 ]
Narkowicz, Christian K. [1 ]
Davies, Noel W. [3 ]
Jacobson, Glenn A. [1 ]
机构
[1] Univ Tasmania, Sch Med, Pharm, Fac Hlth, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Sch Med, Med, Fac Hlth, Hobart, Tas 7001, Australia
[3] Univ Tasmania, Cent Sci Lab, Hobart, Tas 7001, Australia
基金
英国医学研究理事会;
关键词
Smoking; Cotinine; Glucuronide; 3 '-hydroxycotinine; Urine; Ultra-high performance liquid chromatography; TANDEM MASS-SPECTROMETRY; NICOTINE METABOLITE RATIO; SOLID-PHASE EXTRACTION; HUMAN LIVER-MICROSOMES; TRANSDERMAL NICOTINE; SMOKING-CESSATION; HUMAN PLASMA; LC-MS; SMOKERS; CYP2A6;
D O I
10.1080/00032719.2014.979363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of the primary nicotine metabolites, cotinine and trans-3 '-hydroxycotinine, is a useful biomarker of nicotine exposure and metabolism genetics for smoking cessation research. Herein is described an ultra-high performance liquid chromatography-tandem mass spectrometry method for the determination of these primary nicotine metabolites in urine. Urine samples were diluted one hundred-fold with water and introduced into an ultra-high performance liquid chromatography triple quadrupole mass spectrometer using positive ion electrospray ionization with multiple reaction monitoring. Levels of urinary nicotine metabolites: cotinine, trans-3 '-hydroxycotinine, and their respective glucuronides were determined directly using deuterated internal standards and compared with indirect determination by enzymatic hydrolysis. The assay was applied to a community sample of smokers' urine (n=280). The assay demonstrated satisfactory performance (relative standard deviation of 1.6-6.5 percent at the 1000 nanograms per milliliter level and >98 percent recovery) suitable for application to smoking studies with a run time less than five minutes. The mean (min-max) levels of cotinine and cotinine-glucuronide were 968 (31-3831) and 976 (9-5607) nanograms per milliliter. The mean (min-max) levels of trans-3 '-hydroxycotinine and trans-3 '-hydroxycotinine-glucuronide were 3529 (13-21337) and 722 (0-4633) nanograms per milliliter. Direct determination of glucuronide metabolites was superior to indirect measurement using enzymatic hydrolysis, where there was evidence of loss of metabolites during sample preparation. A sensitive and selective ultra-high performance liquid chromatography-tandem mass spectrometry assay was successfully developed for the determination of cotinine, trans-3 '-hydroxycotinine, and their glucuronides in urine. The rapid and simple sample preparation makes this assay suitable for high throughput studies involving nicotine metabolism phenotype for both cytochrome P450 2A6 and uridine 5 '-diphospho-glucuronosyltransferase, smoking prevalence, and cessation studies.
引用
收藏
页码:1217 / 1233
页数:17
相关论文
共 50 条
  • [21] A high-throughput method for the determination of quinolones in different matrices by ultra-high performance liquid chromatography with fluorescence detection
    Arroyo-Manzanares, Natalia
    Huertas-Perez, Jose F.
    Lombardo-Aguei, Manuel
    Gamiz-Gracia, Laura
    Garcia-Campana, Ana M.
    ANALYTICAL METHODS, 2015, 7 (01) : 253 - 259
  • [22] Simultaneous determination of fifteen heterocyclic aromatic amines in the urine of smokers and nonsmokers using ultra-high performance liquid chromatography-tandem mass spectrometry
    Fu, Yufeng
    Zhao, Ge
    Wang, Sheng
    Yu, Jingjing
    Xie, Fuwei
    Wang, Hui
    Xie, Jianping
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1333 : 45 - 53
  • [23] Quantification of Glutamate and Aspartate by Ultra-High Performance Liquid Chromatography
    Agius, Carlos
    von Tucher, Sabine
    Poppenberger, Brigitte
    Rozhon, Wilfried
    MOLECULES, 2018, 23 (06):
  • [24] High-performance liquid chromatographic determination of cotinine in urine in isocratic mode
    Ceppa, F
    El Jahiri, Y
    Mayaudon, H
    Dupuy, O
    Burnat, P
    JOURNAL OF CHROMATOGRAPHY B, 2000, 746 (02): : 115 - 122
  • [25] Ultra-High Performance Liquid Chromatography for the analysis of steviol glycosides
    Cabooter, D.
    Amery, R.
    Jooken, E.
    Meesschaert, B.
    Desmet, G.
    STEVIA: SCIENCE, NO FICTION, 2010, : 83 - 100
  • [26] Determination of benzimidazole residues in bovine milk by ultra-high performance liquid chromatography-tandem mass spectrometry
    Xia, Xi
    Dong, Yichun
    Luo, Pengjie
    Wang, Xia
    Li, Xiaowei
    Ding, Shuangyang
    Shen, Jianzhong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (30): : 3174 - 3180
  • [27] Determination of valnemulin in swine and bovine tissues by ultra-high performance liquid chromatography-tandem mass spectrometry
    Li, Hui
    Wang, Yingyu
    Li, Xiaowei
    Fu, Qin
    Shan, Yawen
    Liu, Tianhe
    Xia, Xi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1014 : 102 - 106
  • [28] Determination of glucocorticoids in sewage and river waters by ultra-high performance liquid chromatography-tandem mass spectrometry
    Herrero, P.
    Borrull, F.
    Pocurull, E.
    Marce, R. M.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1224 : 19 - 26
  • [29] Determination of Ciprofloxacin, Enrofloxacin, and Marbofloxacin in Bovine Urine, Serum, and Milk by Microextraction by a Packed Sorbent Coupled to Ultra-High Performance Liquid Chromatography
    Aresta, Antonella
    Cotugno, Pietro
    Zambonin, Carlo
    ANALYTICAL LETTERS, 2019, 52 (05) : 790 - 802
  • [30] Determination of 82 veterinary drugs in swine waste lagoon sludge by ultra-high performance liquid chromatography-tandem mass spectrometry
    Li, Xiaowei
    Guo, Ping
    Shan, Yawen
    Ke, Yuebin
    Li, Hui
    Fu, Qin
    Wang, Yingyu
    Liu, Tianhe
    Xia, Xi
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1499 : 57 - 64