Elimination of micropollutants and transformation products from a wastewater treatment plant effluent through pilot scale ozonation followed by various activated carbon and biological filters

被引:172
作者
Knopp, Gregor [1 ]
Prasse, Carsten [2 ,3 ]
Ternes, Thomas A. [2 ]
Comel, Peter [1 ]
机构
[1] Tech Univ Darmstadt, Dept Wastewater Technol & Water Reuse, Inst IWAR, Franziska Braun Str 7, D-64287 Darmstadt, Germany
[2] Fed Inst Hydrol BfG, Mainzer Tor 1, D-56068 Koblenz, Germany
[3] Univ Calif Berkeley, Dept Civil & Environm Engn, 406 OBrien Hall, Berkeley, CA 94720 USA
关键词
Micropollutants; Transformation products; Ozonation; Activated carbon filtration; Biological filtration; Wastewater treatment; PERSONAL CARE PRODUCTS; RAY CONTRAST-MEDIA; ORGANIC MICROPOLLUTANTS; ENVIRONMENTAL RISK; REMOVAL EFFICIENCY; CONTROL PARAMETER; DRINKING-WATER; BY-PRODUCT; OXIDATION; OZONE;
D O I
10.1016/j.watres.2016.04.069
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Conventional wastewater treatment plants are ineffective in removing a broad range of micropollutants, resulting in the release of these compounds into the aquatic environment, including natural drinking water resources. Ozonation is a suitable treatment process for micropollutant removal, although, currently, little is known about the formation, behavior, and removal of transformation products (TP) formed during ozonation. We investigated the elimination of 30 selected micropollutants (pharmaceuticals, X-ray contrast media, industrial chemicals, and TP) by biological treatment coupled with ozonation and, subsequently, in parallel with two biological filters (BF) or granular activated carbon (GAC) filters. The selected micropollutants were removed to very different extents during the conventional biological wastewater treatment process. Ozonation (specific ozone consumption: 0.87 +/- 0.29 g(03) g(DOG)(-1) hydraulic retention time: 17 +/- 3 min) eliminated a large number of the investigated micropollutants. Although 11 micropollutants could still be detected after ozonation, most of these were eliminated in subsequent GAC filtration at bed volumes (BV) of approximately 25,000 m(3) m(-3). In contrast, no additional removal of micropollutants was achieved in the BF. Ozonation of the analgesic tramadol led to the formation of tramadol-N-oxide that is effectively eliminated by GAC filters, but not by BF. For the antiviral drug acyclovir, the formation of carboxy-acyclovir was observed during activated sludge treatment, with an average concentration of 3.4 +/- 1.4 mu g L-1 detected in effluent samples. Subsequent ozonation resulted in the complete elimination of carboxy-acyclovir and led to the formation of N-(4-carbamoyl-2-imino-5oxo imidazolidin)-formamido-N-methoxyacetetic acid (COFA; average concentration: 2.6 +/- 1.0 mu g L-1). Neither the BF nor the GAC filters were able to remove COFA. These results highlight the importance of considering TP in the evaluation of advanced wastewater treatment processes. The results further indicate that post-treatment of ozonated wastewater with GAC filtration seems to be more suitable than BF, due to the sorption of formed TP to the activated carbon. (c) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:580 / 592
页数:13
相关论文
共 87 条
[1]   UV254 absorbance as real-time monitoring and control parameter for micropollutant removal in advanced wastewater treatment with powdered activated carbon [J].
Altmann, Johannes ;
Massa, Lukas ;
Sperlich, Alexander ;
Gnirss, Regina ;
Jekel, Martin .
WATER RESEARCH, 2016, 94 :240-245
[2]   Direct comparison of ozonation and adsorption onto powdered activated carbon for micropollutant removal in advanced wastewater treatment [J].
Altmann, Johannes ;
Ruhl, Aki Sebastian ;
Zietzschmann, Frederik ;
Jekel, Martin .
WATER RESEARCH, 2014, 55 :185-193
[3]  
[Anonymous], 2015, 3840747201507 DIN
[4]  
[Anonymous], 2012, Mikroverunreinigungen aus Kommunalem Abwasser. Verfahren zur Weitergehenden Elimination auf Klranlagen (Micropollutants from Municipal Wastewater. Methods for Further Elimination at Sewage Treatment Plants)
[5]  
ARGEX NV, 2012, TECHN SHEET EXP CLAY
[6]   Carbamazepine and its metabolites in wastewater: Analytical pitfalls and occurrence in Germany and Portugal [J].
Bahlmann, Arnold ;
Brack, Werner ;
Schneider, Rudolf J. ;
Krauss, Martin .
WATER RESEARCH, 2014, 57 :104-114
[7]   SUVA as control parameter for the effective ozonation of organic pollutants in secondary effluent [J].
Bahr, C. ;
Schumacher, J. ;
Ernst, M. ;
Luck, F. ;
Heinzmann, B. ;
Jekel, M. .
WATER SCIENCE AND TECHNOLOGY, 2007, 55 (12) :267-274
[8]   Evaluation of advanced treatment technologies for the elimination of pharmaceutical compounds [J].
Baumgarten, S. ;
Schroeder, H. Fr. ;
Charwath, C. ;
Lange, M. ;
Beier, S. ;
Pinnekamp, J. .
WATER SCIENCE AND TECHNOLOGY, 2007, 56 (05) :1-8
[9]   Removal of micropollutants in municipal wastewater treatment plants by powder-activated carbon [J].
Boehler, M. ;
Zwickenpflug, B. ;
Hollender, J. ;
Ternes, T. ;
Joss, A. ;
Siegrist, H. .
WATER SCIENCE AND TECHNOLOGY, 2012, 66 (10) :2115-2121
[10]  
Bollmann A. F., 2016, J HAZARD MAT UNPUB