Blood Coagulation Testing Smartphone Platform Using Quartz Crystal Microbalance Dissipation Method

被引:15
|
作者
Yao, Jia [1 ,2 ]
Feng, Bin [1 ]
Zhang, Zhiqi [1 ]
Li, Chuanyu [1 ,3 ]
Zhang, Wei [1 ]
Guo, Zhen [1 ]
Zhao, Heming [2 ]
Zhou, Lianqun [1 ]
机构
[1] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, CAS Key Lab Biomed Diagnost, Suzhou 215163, Peoples R China
[2] Soochow Univ, Sch Elect & Informat Engn, Suzhou 215006, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
blood coagulation; quartz crystal microbalance; dissipation; smartphone; point of care testing; QCM-D; WHOLE-BLOOD; VISCOELASTIC PROPERTIES; PROTHROMBIN TIME; ADSORPTION; PLASMA; SENSOR; BIOSENSOR; FREQUENCY; ACTIVATION;
D O I
10.3390/s18093073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood coagulation function monitoring is important for people who are receiving anticoagulation treatment and a portable device is needed by these patients for blood coagulation self-testing. In this paper, a novel smartphone based blood coagulation test platform was proposed. It was developed based on parylene-C coated quartz crystal microbalance (QCM) dissipation measuring and analysis. The parylene-C coating constructed a robust and adhesive surface for fibrin capturing. The dissipation factor was obtained by measuring the frequency response of the sensor. All measured data were sent to a smartphone via Bluetooth for dissipation calculation and blood coagulation results computation. Two major coagulation indexes, activated partial thromboplastin time (APTT) and prothrombin time (PT) were measured on this platform compared with results by a commercial hemostasis system in a clinical laboratory. The measurement results showed that the adjusted R-square (R-2) value for APTT and PT measurements were 0.985 and 0.961 respectively. The QCM dissipation method for blood coagulation measurement was reliable and effective and the platform together with the QCM dissipation method was a promising solution for point of care blood coagulation testing.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] The modelling of blood coagulation using the quartz crystal microbalance
    Efremov, Vitaly
    Killard, Anthony J.
    Byrne, Barry
    Lakshmanan, Ramji S.
    JOURNAL OF BIOMECHANICS, 2013, 46 (03) : 437 - 442
  • [2] Quartz Crystal Microbalance with Dissipation
    不详
    TENSIDE SURFACTANTS DETERGENTS, 2009, 46 (02) : 121 - 121
  • [3] A nanocell for quartz crystal microbalance and quartz crystal microbalance with dissipation-monitoring sensing
    Ohlsson, Gabriel
    Langhammer, Christoph
    Zoric, Igor
    Kasemo, Bengt
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (08):
  • [4] Acoustic quantification of ATP using a quartz crystal microbalance with dissipation
    Cengiz Oezalp, Veli
    ANALYST, 2011, 136 (23) : 5046 - 5050
  • [5] A study of adsorption of dodecylamine on quartz surface using quartz crystal microbalance with dissipation
    Kou, J.
    Tao, D.
    Xu, G.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2010, 368 (1-3) : 75 - 83
  • [6] Acoustic Immunosensing of Exosomes Using a Quartz Crystal Microbalance with Dissipation Monitoring
    Suthar, Jugal
    Parsons, Edward S.
    Hoogenboom, Bart W.
    Williams, Gareth R.
    Guldin, Stefan
    ANALYTICAL CHEMISTRY, 2020, 92 (05) : 4082 - 4093
  • [7] Open Source Quartz Crystal Microbalance with dissipation monitoring
    Mista, C.
    Zalazar, M.
    Penalva, A.
    Martina, M.
    Reta, J. M.
    20TH ARGENTINEAN BIOENGINEERING SOCIETY CONGRESS (XX ARGENTINE BIOENGINEERING CONGRESS AND IX CONFERENCE OF CLINICAL ENGINEERING), (SABI 2015), 2016, 705
  • [8] Probing Bitumen Liberation by a Quartz Crystal Microbalance with Dissipation
    Xiang, Bailin
    Liu, Qingxia
    Long, Jun
    ENERGY & FUELS, 2018, 32 (07) : 7451 - 7457
  • [9] On dissipation of quartz crystal microbalance as a mechanical spectroscopy tool
    Voinova, MV
    Jonson, M
    Kasemo, B
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2004, 18 (04): : 537 - 544
  • [10] Quartz Crystal Microbalance - a platform for biological measurements
    Swiatkowski, Michal
    Waszczuk, Karol
    Olszewski, Jaroslaw
    Gula, Grzegorz
    Drulis-Kawa, Zuzanna
    Gotszalk, Teodor
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (10): : 96 - 98