Performance of two different types of passive samplers for the GC/ECD-FID determination of environmental VOC levels in air

被引:44
作者
Begerow, J [1 ]
Jermann, E [1 ]
Keles, T [1 ]
Dunemann, L [1 ]
机构
[1] Med Inst Umwelthyg, Dept Analyt Chem, D-40225 Dusseldorf, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1999年 / 363卷 / 04期
关键词
D O I
10.1007/s002160051209
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two types of passive samplers differing in their geometry (OVM 3500 by 3M, ORSA 5 by Drager) were compared with respect to their suitability for typical environmental indoor and outdoor VOC concentrations. Benzene, toluene, o-, m-, p-xylene, ethylbenzene, tetrachloroethene, trichloroethene, nonane and ethyl acetate were representatively analyzed by dual-column capillary gas chromatography with tandem ECD-FID detection. There was a good correlation between the results obtained with OVM 3500 and ORSA 5 monitors indicating that both monitors can be used for this kind of application. The ratio between the results for indoor air sampling with OVM 3500 and ORSA 5 monitors was between 0.89 and 1.14 showing no systematic variation. For outdoor air sampling the ratio was between 1.06 and 1.26 indicating that the results obtained with OVM 3500 monitors were slightly higher. Reproducibility was slightly better when using ORSA 5 monitors. But, due to the higher sampling rates which are a result of the larger cross-sectional area, signal-to-noise ratios obtained with OVM 3500 monitors were between six to nine times higher than those of ORSA 5 samplers. Blank values of the unexposed sam piers were comparable for both sampler types. As a consequence, detection limits were by a factor of 1.5 to 4 better for OVM 3500 monitors.
引用
收藏
页码:399 / 403
页数:5
相关论文
共 20 条
[1]  
*3M DTSCH GMBH, 1986, TECHN INF 3M MON
[2]   PASSIVE SAMPLING FOR VOLATILE ORGANIC-COMPOUNDS (VOCS) IN AIR AT ENVIRONMENTALLY RELEVANT CONCENTRATION LEVELS [J].
BEGEROW, J ;
JERMANN, E ;
KELES, T ;
RANFT, U ;
DUNEMANN, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (06) :549-554
[3]   Screening method for the determination of 28 volatile organic compounds in indoor and outdoor air at environmental concentrations using dual-column capillary gas chromatography with tandem electron-capture-flame ionization detection [J].
Begerow, J ;
Jermann, E ;
Keles, T ;
Koch, T ;
Dunemann, L .
JOURNAL OF CHROMATOGRAPHY A, 1996, 749 (1-2) :181-191
[4]   THE VALIDATION OF A PASSIVE SAMPLER FOR INDOOR AND OUTDOOR CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS [J].
COHEN, MA ;
RYAN, PB ;
YANAGISAWA, Y ;
HAMMOND, SK .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1990, 40 (07) :993-997
[5]  
ELKE K, 1998, UNPUB J CHROMATOGR
[6]   Summary of the NIOSH guidelines for air sampling and analytical method development and evaluation [J].
Kennedy, ER ;
Fischbach, TJ ;
Song, RG ;
Eller, PM ;
Shulman, SA .
ANALYST, 1996, 121 (09) :1163-1169
[7]  
KETTRUP A, 1991, ANAL HAZARDOUS SUBST, V1
[8]  
KRAUSE C, 1987, 4TH P INT C IND AIR, V1, P102
[9]   A NEW PERSONAL BADGE MONITOR FOR ORGANIC VAPORS [J].
LAUTENBERGER, WJ ;
KRING, EV ;
MORELLO, JA .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (10) :737-747
[10]  