Interstudy reproducibility of SSFP Cine magnetic resonance: Impact of magnetic field strength and parallel imaging

被引:16
作者
Maroules, Christopher D. [1 ]
McColl, Roderick [1 ]
Khera, Amit [2 ]
Peshock, Ronald M. [1 ,2 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Radiol, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Internal Med, Donald W Reynolds Cardiovasc Clin Res Ctr, Dallas, TX 75390 USA
关键词
cardiovascular MRI; 3; Tesla; reproducibility;
D O I
10.1002/jmri.21343
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study the effects of field strength and parallel imaging on image contrast and interstudy reproducibility of right and left ventricular (RV and LV) measurements using steady-state free precession (SSFP) cardiovascular magnetic resonance (CMR). Materials and Methods: Thirty-two subjects (20 normal, 12 cardiac patients) underwent four SSFP cine short-axis imaging studies: two at 1.5T, one at 3T, and another at 3T with parallel imaging (SENSE). RV and LV contrast-to-noise ratios (CNRs) were compared between methods. Interstudy reproducibility of RV and LV measurements were assessed by Bland-Altman analyses. Results: 3T SENSE imaging reduced total imaging time from 8 +/- 2 minutes to 3 +/- 1 minute (P < 0.001). A significant gain in LV CNR was detected between 1.5T and 3T with SENSE (43.8 +/- 6.5 vs. 48.4 +/- 7.4, P = 0.01), but no significant gain was detected in RV CNR. The reproducibility of LV and RV measurements between two 1.5T studies was not significantly different from the reproducibility between a 1.5T study and a 3T study with SENSE. Conclusion: SENSE imaging at 3T is a reproducible technique for assessing RV and LV structure and function.
引用
收藏
页码:1139 / 1145
页数:7
相关论文
共 31 条
[1]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[2]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
CUTBERLET M, 2006, INVEST RADIOL, V41, P154
[5]   Myocardial perfusion Imaging based on the blood oxygen level-dependent effect using T2-prepared steady-state free-precession magnetic resonance Imaging [J].
Fieno, DS ;
Shea, SM ;
Li, YZ ;
Harris, KR ;
Finn, JP ;
Li, DB .
CIRCULATION, 2004, 110 (10) :1284-1290
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]   Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy [J].
Grothues, F ;
Smith, GC ;
Moon, JCC ;
Bellenger, NG ;
Collins, P ;
Klein, HU ;
Pennell, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (01) :29-34
[8]   Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance [J].
Grothues, F ;
Moon, JC ;
Bellenger, NG ;
Smith, GS ;
Klein, HU ;
Pennell, DJ .
AMERICAN HEART JOURNAL, 2004, 147 (02) :218-223
[9]  
GUAN H, 1996, BIOMETRICS, V52, P1195
[10]   Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging:: comparison of 1.5 T vs. 3.0 T [J].
Gutberlet, M ;
Schwinge, K ;
Freyhardt, P ;
Spors, B ;
Grothoff, M ;
Denecke, T ;
Lüdemann, L ;
Noeske, R ;
Niendorf, T ;
Felix, R .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1586-1597