Flexural fatigue of denture base polymer with fiber-reinforced composite reinforcement

被引:26
作者
Narva, KK [1 ]
Lassila, LVJ [1 ]
Vallittu, PK [1 ]
机构
[1] Univ Turku, Inst Dent, Dept Prosthet Dent & Biomat Res, FIN-20520 Turku, Finland
关键词
fibres; glass fibres; fatigue; fiber-reinforced composite;
D O I
10.1016/j.compositesa.2005.01.025
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Flexural fatigue of denture base polymer with various fiber reinforcements was investigated. The test specimens (3 X 5 X 50 mm(3), n = 6) were made of autopolymerized polymethylmethacrylate (PMMA). The following fiber reinforcements, referred to as partial fiber reinforcements, were embedded into the denture base resin: ribbon polyethylene fibers, unidirectional dimethacrylate-impregnated glass fibers, dimethacrylate-PMMA-impregnated glass fibers and PMMA-preimpregnated glass fibers. Number of cycles to failure was measured in water by the constant deflection fatigue test with a maximum of 100,000 cycles of the test specimens with partial fiber reinforcement placed at various locations, namely, on the compression or tension side. Magnitude of deflection was I mm and loading frequency 2.0 Hz. The number of loading cycles needed to cause a fracture in the test specimen was considered the fatigue failure of the specimen. The results of this study suggest that the fiber reinforcements that allowed even fiber distribution in the cross-section or were placed on the tensile side reinforced the test specimens of PMMA most effectively. The PMMA-preimpregnated glass-fiber reinforcements resulted in a higher number of loading cycles (maximum 100,000) than polyethylene fiber ribbon (2886 cycles in compression, 23,220 in tension). (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1275 / 1281
页数:7
相关论文
共 37 条
[1]  
Bae JM, 2001, INT J PROSTHODONT, V14, P33
[2]  
Bates JF, 1991, REMOVABLE DENTURE CO, P108
[3]   DENTURE FRACTURE - A SURVEY [J].
DARBAR, UR ;
HUGGETT, R ;
HARRISON, A .
BRITISH DENTAL JOURNAL, 1994, 176 (09) :342-345
[4]   PREVENTIVE PROSTHODONTICS - MAXILLARY DENTURE FRACTURE [J].
FARMER, JB .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (02) :172-175
[5]  
Hargreaves A S, 1969, Br Dent J, V126, P451
[6]   MASTICATORY MUSCLE FORCE AND FACIAL MORPHOLOGY IN MAN [J].
INGERVALL, B ;
HELKIMO, E .
ARCHIVES OF ORAL BIOLOGY, 1978, 23 (03) :203-206
[7]   Effect of water and artificial saliva on the low cycle fatigue resistance of cobalt-chromium dental alloy [J].
Lassila, LVJ ;
Vallittu, PK .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (06) :708-713
[8]   BITE FORCE AND ITS CORRELATIONS IN DIFFERENT DENTURE TYPES [J].
LASSILA, V ;
HOLMLUND, I ;
KOIVUMAA, KK .
ACTA ODONTOLOGICA SCANDINAVICA, 1985, 43 (03) :127-132
[9]   A MULTI-STATION MACHINE FOR THE FATIGUE TESTING OF DENTURE BASE MATERIALS [J].
MANLEY, TR ;
STONEBANKS, JA .
BIOMATERIALS, 1980, 1 (03) :125-128
[10]   Repair of denture base resin using woven metal and glass fiber: Effect of methylene chloride pretreatment [J].
Nagai, E ;
Otani, K ;
Satoh, Y ;
Suzuki, S .