Effect of bone thickness on alveolar bone-height measurements from cone-beam computed tomography images

被引:142
作者
Sun, Zongyang [1 ]
Smith, Tharon
Kortam, Sahira [1 ]
Kim, Do-Gyoon [1 ]
Tee, Boon Ching [1 ]
Fieldse, Henry [1 ]
机构
[1] Ohio State Univ, Coll Dent, Div Orthodont, Columbus, OH 43210 USA
关键词
ACCURACY; RELIABILITY; MODEL;
D O I
10.1016/j.ajodo.2010.08.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Cone-beam computed tomography (CBCT) has been used to assess alveolar bone changes after rapid palatal expansion. The purpose of this study was to investigate the accuracy of alveolar bone-height measurements from CBCT images with varied bone thicknesses and imaging resolutions. Methods: Eleven maxillary specimens from 6-month-old pigs were measured for alveolar bone height (distance between drilled reference holes and alveolar crests) at 6 locations with a digital caliper, followed by CBCT scanning at 0.4-mm and 0.25-mm voxel sizes. Buccal alveolar bone of these locations was then reduced approximately by 0.5 to 1.5 mm, followed by CBCT rescanning with the same voxel sizes. The CBCT images were measured by using 3-dimensional software to determine alveolar bone height and thickness in buccolingual slices by independent, blinded raters. The specimens were subsequently cut into buccolingual sections at reference-hole levels, and direct bone height and thickness were measured from these sections. Intrarater and interrater repeatability and the differences between CBCT and direct measurements were assessed. Results: Excellent intrarater (intraclass correlations, r = 0.89-0.98) and good interrater (r = 0.64-0.90) repeatability values were found for alveolar bone-height measurements from the CBCT images. Before alveolar bone reduction, the thickness was much greater than the CBCT voxel size (0.4 mm), and bone-height measurements from the CBCT images were 0.5 to 1 mm more than the direct measurements (paired t tests, P <0.017 at most locations). After bone reduction, the thickness at the subcrest 1-mm level was near or below the CBCT voxel size (0.4 mm), and bone-height measurements from the CBCT images were 0.9 to 1.2 mm less than the direct measurements (paired t tests, P <0.017 at most locations). These measurement inaccuracies were substantially improved by decreasing the CBCT voxel size to 0.25 mm. Conclusions: Alveolar bone-height measurements from conventional clinical 0.4-mm voxel size CBCT images might overestimate alveolar bone-height loss associated with rapid palatal expansion. (Am J Orthod Dentofacial Orthop 2011;139:e117-e127)
引用
收藏
页码:e117 / e127
页数:11
相关论文
共 20 条
[1]   Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine [J].
Ballrick, John W. ;
Palomo, J. Martin ;
Ruch, Edward ;
Amberman, B. Douglas ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (04) :573-582
[2]   Reliability and accuracy of cone-beam computed tomography dental measurements [J].
Baumgaertel, Sebastian ;
Palomo, J. Martin ;
Palomo, Leena ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :19-25
[3]   Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull [J].
Berco, Mauricio ;
Rigali, Paul H., Jr. ;
Miner, R. Matthew ;
DeLuca, Stephelynn ;
Anderson, Nina K. ;
Will, Leslie A. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :17.e1-17.e9
[4]   Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root-fractured permanent teeth [J].
Bornstein, Michael M. ;
Woelner-Hanssen, Andrea B. ;
Sendi, Pedram ;
von Arx, Thomas .
DENTAL TRAUMATOLOGY, 2009, 25 (06) :571-577
[5]   NON-LINEAR PARTIAL VOLUME ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1980, 7 (03) :238-248
[6]   Imaging of the midpalatal suture in a porcine model: Flat-panel volume computed tomography compared with multislice computed tomography [J].
Hahn, Wolfram ;
Fricke-Zech, Susanne ;
Fialka-Fricke, Julia ;
Dullin, Christian ;
Zapf, Antonia ;
Gruber, Rudolf ;
Sennhenn-kirchner, Sabine ;
Kubein-Meesenburg, Dietmar ;
Sadat-Khonsari, Reza .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03) :443-449
[7]  
Hass AJ., 1961, Angle Orthod, V31, P73
[8]  
Hechler Steven L, 2008, Dent Clin North Am, V52, P809, DOI 10.1016/j.cden.2008.05.001
[9]   Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography [J].
Hilgers, ML ;
Scarfe, WC ;
Scheetz, JP ;
Farman, AG .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (06) :803-811
[10]   The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone [J].
Kim, DG ;
Christopherson, GT ;
Dong, XN ;
Fyhrie, DP ;
Yeni, YN .
BONE, 2004, 35 (06) :1375-1382