Analysis of trace mercury in water by solid phase extraction using dithizone modified nanometer titanium dioxide and cold vapor atomic absorption spectrometry

被引:31
作者
Ma Xiaoguo [1 ]
Huang Bei [1 ]
Cheng Meiqing [2 ]
机构
[1] Guangdong Univ Technol, Fac Environm Sci & Engn, Guangzhou 510090, Peoples R China
[2] Maoming Univ, Dept Chem Engn, Maoming 525000, Peoples R China
关键词
analytical chemistry; mercury; solid-phase extraction; TiO2; nanoparticle; cold vapor atomic adsorption spectrometry (CVAAS); PRECONCENTRATION; SAMPLES;
D O I
10.1016/S1001-0521(08)60004-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new method for analysis of trace mercury in water samples was developed, based on the combination of preconcentration/separation using dithizone-modified nanometer titanium. dioxide (TiO2) as a solid phase extractant and determination by cold vapor atomic adsorption spectrometry (CVAAS). Dithizone was dissolved with alcohol and loaded on the surface of nano-sized TiO2 powders by stirring. The static adsorption behavior of Hg2+ on the dithizone-modified nanoparticles was investigated in detail. It was found that excellent adsorption ratio for Hg2+ could be obtained in die pH range of 7-8 with an oscillation time of 15 min, and a 5 mL of 3.5 mol center dot L-1 HCI solution could quantitatively elute Hg2+ from nanometer TiO2 powder. Common coexisting ions caused no obvious influence on the determination of mercury. The mechanisms for the adsorption and desorption were discussed. The detection limit (3 sigma) for Hg2+ was calculated to be 5 ng center dot L-1. The proposed method was applied to the determination of Hg2+ in a mineral water sample and a Zhujiang River water sample. By the standard addition method, the average recoveries were found to be 94.4%-108.3% with RSD (n = 5) of 2.9%-3.5%.
引用
收藏
页码:541 / 546
页数:6
相关论文
共 9 条
[1]  
Friberg L., 1986, HDB TOXICOLOGY METAL
[2]  
MA XG, 2004, J ANAL ATOM SPECTROM, V38, P635
[3]  
Mohamed EM, 2000, ANAL CHIM ACTA, V415, P33
[4]   Determination of mercury species with a resin functionalized with a 1,2-bis(o-aminophenylthio)ethane moiety [J].
Mondal, BC ;
Das, AK .
ANALYTICA CHIMICA ACTA, 2003, 477 (01) :73-80
[5]   Studies on the liquid-liquid extraction of nickel(II), zinc(II), cadmium(II), mercury(II) and lead(II) with 1-phenyl-3hydroxy-4-dodecyldithiocarboxylate-5-pyrazolone [J].
Oliva, A ;
Molinari, A ;
Zúñiga, F ;
Ponce, P .
MICROCHIMICA ACTA, 2002, 140 (3-4) :201-203
[6]   Direct and trophic contamination of the herbivorous carp Ctenophatyngodon idella by inorganic mercury and methylmercury [J].
Simon, O ;
Boudou, A .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2001, 50 (01) :48-59
[7]   Solid-phase microextraction for the analysis of biological samples [J].
Theodoridis, G ;
Koster, EHM ;
de Jong, GJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 745 (01) :49-82
[8]   COPRECIPITATION BEHAVIOR OF 5,8-POLYQUINOLYL POLYDISULPHIDE FOR TRACE-ELEMENT PRECONCENTRATION FROM AQUEOUS-SOLUTION [J].
VIRCAVS, M ;
RONE, V ;
PELNE, A ;
VIRCAVA, D .
ANALYTICA CHIMICA ACTA, 1994, 299 (02) :291-298
[9]   Simultaneous on-line preconcentration and determination of trace metals in environmental samples by flow injection combined with inductively coupled plasma mass spectrometry using a manometer-sized alumina packed micro-column [J].
Yin, J ;
Jiang, ZC ;
Chang, G ;
Hu, B .
ANALYTICA CHIMICA ACTA, 2005, 540 (02) :333-339