Tapered stem geometry provides superior initial fixation stability to cylindrical stem geometry in the setting of severe bone loss: A finite element analysis

被引:1
|
作者
Kosmopoulos, Victor [1 ]
Russell, Robert D. [2 ]
Rodrigues, Danieli C. [3 ]
Bucci, Gabriella [4 ]
Huo, Michael H. [2 ]
机构
[1] Orthoped & Neurol Res Inst, 6900 Harris Pkwy,Suite 210, Ft Worth, TX 76132 USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Orthopaed Surg, Dallas, TX USA
[3] Univ Texas Dallas, Dept Bioengn, Richardson, TX USA
[4] Texas Hlth Sports Med, Ft Worth, TX USA
关键词
biomechanics; bone defect; implant design; revision surgery; total hip arthroplasty; total hip replacement; TOTAL HIP-ARTHROPLASTY; PROXIMAL FEMUR; FEMORAL STEM; FOLLOW-UP; IMPLANT MICROMOTION; COATED STEMS; REVISION; INTERFACE; MORPHOLOGY; TERM;
D O I
10.1002/eng2.12218
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Initial stability of cementless stems used in total hip arthroplasty (THA) is critical for subsequent osseointegration at the bone/implant interface. In the setting of revision THA, there is frequently less intact femoral bone available for fixation of the new stem. This study aims to compare the initial fixation stability between a cylindrical and tapered stem, designed for diaphyseal fixation in a revision THA setting, with increasing bone defect severity. Using finite element analysis, severe Paprosky Type III femoral bone defects were simulated. The cylindrical stem had a 13.3% higher construct stiffness as compared to the tapered stem for the least severe bone defect modeled. In contrast, for the most severe bone defect, the tapered stem showed a 12.3% higher construct stiffness than the cylindrical stem. At the bone/implant interface, the tapered design resulted in less than 20 mu m of maximum tangential micromotion for all the bone defect models, whereas the cylindrical stem exceeded 20 mu m for all and was as high as 70 mu m in the most severe case. Given the limitations of the models presented, the results suggest the tapered stem obtained superior initial fixation as compared to cylindrical stem with increasing bone defect severity.
引用
收藏
页数:13
相关论文
共 5 条
  • [1] Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study
    Russell, Robert D.
    Huo, Michael H.
    Rodrigues, Danieli C.
    Kosmopoulos, Victor
    TECHNOLOGY AND HEALTH CARE, 2016, 24 (06) : 865 - 872
  • [2] Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis
    Massin, P
    Astoin, E
    Lavaste, F
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2003, 89 (02): : 134 - 143
  • [3] Influence of femoral stem geometry, material and extent of porous coating on bone ingrowth and atrophy in cementless total hip arthroplasty: an iterative finite element model
    Folgado, J.
    Fernandes, P. R.
    Jacobs, C. R.
    Pellegrini, V. D., Jr.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2009, 12 (02) : 135 - 145
  • [4] Screw placement through a higher medial portal provides better initial stability in arthroscopic ACL tibial avulsion fracture fixation: a finite element analysis
    Xiao, Yang
    Shi, Changhao
    Deng, Geyang
    Ding, Zichu
    Xu, Jinhuang
    Chen, Bin
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [5] The stability of long-segment and short segment fixation for treating severe burst fractures at the thoracolumbar junction in osteoporotic bone: A finite element analysis
    Wu, Yueh
    Chen, Chia-Hsien
    Tsuang, Fon-Yih
    Lin, Yi-Cheng
    Chiang, Chang-Jung
    Kuo, Yi-Jie
    PLOS ONE, 2019, 14 (02):