Aptamer sandwich assays: human α-thrombin detection using liposome enhancement

被引:38
作者
Edwards, Katie A. [1 ]
Wang, Yang [1 ]
Baeumner, Antje J. [1 ]
机构
[1] Cornell Univ, Dept Biol & Environm Engn, Ithaca, NY 14853 USA
关键词
Aptamer; Liposome; Fluorescence; Sandwich assay; Bioanalytical methods; Nucleic acids/DNA; CHOLERA-TOXIN; ENCAPSULATING LIPOSOMES; INHIBITS THROMBIN; BIVALENT APTAMER; DNA APTAMER; IN-VIVO; ANTICOAGULANT; AFFINITY; ANTIBODY; BINDING;
D O I
10.1007/s00216-010-3920-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescent dye-encapsulating liposomes tagged with aptamers were developed and used as reporting signals in an aptamer-based sandwich assay. alpha-Thrombin was utilized as a prototypical analyte as two well-studied aptamers binding distinct epitopes are available to form a sandwich complex. Cholesteryl-TEG-modified aptamers were embedded into the liposomal lipid bilayer while the interior cavity of the liposomes encapsulated fluorescent sulforhodamine B dye. Such liposomes successfully formed a sandwich complex with alpha-thrombin and a microtiter plate immobilized aptamer, proving that aptamers retain their ability to fold when anchored to the liposome surface. Parameters studied included liposomal aptamer coverage, sandwich aptamer orientation, aptamer label orientation, aptamer spacer length and type, incubation buffer, and aptamer concentration. The optimized conditions found here in the fluorescence assay led to a limit of detection of 64 pM or 2.35 ng/mL, corresponding to 6.4 fmol or 235 pg, respectively, in a 100 mu L volume. This is an order of magnitude lower than previous sandwich aptamer assays using the same sequences with lowest reported limits of detection of 0.45 nM. In addition, the assay was applied successfully to the detection of alpha-thrombin in human plasma. The success of this method in a standard microtiter plate format and the relatively facile functionalization of liposomes with aptamers suggest that this approach provides a versatile option for routine analytical applications.
引用
收藏
页码:2645 / 2654
页数:10
相关论文
共 67 条
  • [1] Surface immobilization methods for aptamer diagnostic applications
    Balamurugan, Subramanian
    Obubuafo, Anne
    Soper, Steven A.
    Spivak, David A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (04) : 1009 - 1021
  • [2] Aptasensor development: Elucidation of critical parameters for optimal aptamer performance
    Baldrich, E
    Restrepo, A
    O'Sullivan, CK
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (23) : 7053 - 7063
  • [3] BARTLETT GR, 1959, J BIOL CHEM, V234, P466
  • [4] Detection of thrombin in human blood by ex-vivo hirudin
    Bichler, J
    Heit, JA
    Owen, WG
    [J]. THROMBOSIS RESEARCH, 1996, 84 (04) : 289 - 294
  • [5] Analytical performances of aptamer-based sensing for thrombin detection
    Bini, Alessandra
    Minunni, Maria
    Tombelli, Sara
    Centi, Sonia
    Mascini, Marco
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (07) : 3016 - 3019
  • [6] SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN
    BOCK, LC
    GRIFFIN, LC
    LATHAM, JA
    VERMAAS, EH
    TOOLE, JJ
    [J]. NATURE, 1992, 355 (6360) : 564 - 566
  • [7] Aptamer inhibits degradation of platelet proteolytically activatable receptor, PAR-1, by thrombin
    Boncler, MA
    Koziolkiewicz, M
    Watala, C
    [J]. THROMBOSIS RESEARCH, 2001, 104 (03) : 215 - 222
  • [8] Thrombin generation profiles in deep venous thrombosis
    Brummel-Ziedins, KE
    Vossen, CY
    Butenas, S
    Mann, KG
    Rosendaal, FR
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2005, 3 (11) : 2497 - 2505
  • [9] Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads
    Centi, Sonia
    Tombelli, Sara
    Minunni, Maria
    Mascini, Marco
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1466 - 1473
  • [10] Clark SL, 2002, ELECTROPHORESIS, V23, P1335, DOI 10.1002/1522-2683(200205)23:9<1335::AID-ELPS1335>3.0.CO