Estimating Dynamic Gait Stability Using Data from Non-aligned Inertial Sensors

被引:48
作者
Bruijn, Sjoerd M. [1 ]
Ten Kate, Warner R. Th. [2 ]
Faber, Gert S. [1 ]
Meijer, Onno G. [1 ,3 ]
Beek, Peter J. [1 ]
van Dieen, Jaap H. [1 ]
机构
[1] Vrije Univ Amsterdam, Fac Human Movement Sci, Res Inst MOVE, NL-1081 BT Amsterdam, Netherlands
[2] Philips Res, Eindhoven, Netherlands
[3] Fujian Med Univ, Affiliated Hosp 2, Quanzhou, Fujian, Peoples R China
关键词
Gait stability; Treadmill walking; Lyapunov exponents; Floquet multipliers; Inertial sensors; HUMAN WALKING; KINEMATIC VARIABILITY; TREADMILL WALKING; OLDER-ADULTS; SPEED; LOCOMOTION; NEUROPATHY; PEOPLE;
D O I
10.1007/s10439-010-0018-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, two methods for quantifying the stability of a dynamical system have been applied to human locomotion: local stability (quantified by finite time maximum Lyapunov exponents, lambda(s) and lambda(L)) and orbital stability (quantified by maximum Floquet multipliers, MaxFm). In most studies published to date, data from optoelectronic measurement systems were used to calculate these measures. However, using wireless inertial sensors may be more practical as they are easier to use, also in ambulatory applications. While inertial sensors have been employed in some studies, it is unknown whether they lead to similar stability estimates as obtained with optoelectronic measurement systems. In the present study, we compared stability measures of human walking estimated from an optoelectronic measurement system with those calculated from an inertial sensor measurement system. Subjects walked on a treadmill at three different speeds while kinematics were recorded using both measurement systems. From the angular velocities and linear accelerations, lambda(s), lambda(L), and MaxFm were calculated. Both measurement systems showed the same effects of walking speed for all variables. Estimates from both measurement systems correlated high for lambda(s) and lambda(L), (R > 0.85) but less strongly for MaxFm (R = 0.66). These results indicate that inertial sensors constitute a valid alternative for an optoelectronic measurement system when assessing dynamic stability in human locomotion, and may thus be used instead, which paves the way to studying gait stability during natural, everyday walking.
引用
收藏
页码:2588 / 2593
页数:6
相关论文
共 31 条
  • [21] Characteristics of functional gait among people with and without peripheral neuropathy
    Manor, Brad
    Li, Li
    [J]. GAIT & POSTURE, 2009, 30 (02) : 253 - 256
  • [22] DANGERS OF GEOMETRIC FILTERING
    MEES, AI
    JUDD, K
    [J]. PHYSICA D, 1993, 68 (3-4): : 427 - 436
  • [23] Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation
    Roetenberg, D
    Luinge, HJ
    Baten, CTM
    Veltink, PH
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (03) : 395 - 405
  • [24] A PRACTICAL METHOD FOR CALCULATING LARGEST LYAPUNOV EXPONENTS FROM SMALL DATA SETS
    ROSENSTEIN, MT
    COLLINS, JJ
    DE LUCA, CJ
    [J]. PHYSICA D-NONLINEAR PHENOMENA, 1993, 65 (1-2) : 117 - 134
  • [25] Falls in older people: epidemiology, risk factors and strategies for prevention
    Rubenstein, Laurence Z.
    [J]. AGE AND AGEING, 2006, 35 : 37 - 41
  • [26] Schablowski A, 2006, LECT NOTES CONTR INF, V340, P345
  • [27] Dynamic stability of passive dynamic walking on an irregular surface
    Su, Jimmy Li-Shin
    Dingwell, Jonathan B.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (06): : 802 - 810
  • [28] VANACHT V, 2007, P 29 I C IEEE EMBC L
  • [29] YAKHDANI HRF, 2010, CLIN BIOMECH
  • [30] Effect of prolonged free-walking fatigue on gait and physiological rhythm
    Yoshino, K
    Motoshige, T
    Araki, T
    Matsuoka, K
    [J]. JOURNAL OF BIOMECHANICS, 2004, 37 (08) : 1271 - 1280