Estimating Dynamic Gait Stability Using Data from Non-aligned Inertial Sensors

被引:48
作者
Bruijn, Sjoerd M. [1 ]
Ten Kate, Warner R. Th. [2 ]
Faber, Gert S. [1 ]
Meijer, Onno G. [1 ,3 ]
Beek, Peter J. [1 ]
van Dieen, Jaap H. [1 ]
机构
[1] Vrije Univ Amsterdam, Fac Human Movement Sci, Res Inst MOVE, NL-1081 BT Amsterdam, Netherlands
[2] Philips Res, Eindhoven, Netherlands
[3] Fujian Med Univ, Affiliated Hosp 2, Quanzhou, Fujian, Peoples R China
关键词
Gait stability; Treadmill walking; Lyapunov exponents; Floquet multipliers; Inertial sensors; HUMAN WALKING; KINEMATIC VARIABILITY; TREADMILL WALKING; OLDER-ADULTS; SPEED; LOCOMOTION; NEUROPATHY; PEOPLE;
D O I
10.1007/s10439-010-0018-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, two methods for quantifying the stability of a dynamical system have been applied to human locomotion: local stability (quantified by finite time maximum Lyapunov exponents, lambda(s) and lambda(L)) and orbital stability (quantified by maximum Floquet multipliers, MaxFm). In most studies published to date, data from optoelectronic measurement systems were used to calculate these measures. However, using wireless inertial sensors may be more practical as they are easier to use, also in ambulatory applications. While inertial sensors have been employed in some studies, it is unknown whether they lead to similar stability estimates as obtained with optoelectronic measurement systems. In the present study, we compared stability measures of human walking estimated from an optoelectronic measurement system with those calculated from an inertial sensor measurement system. Subjects walked on a treadmill at three different speeds while kinematics were recorded using both measurement systems. From the angular velocities and linear accelerations, lambda(s), lambda(L), and MaxFm were calculated. Both measurement systems showed the same effects of walking speed for all variables. Estimates from both measurement systems correlated high for lambda(s) and lambda(L), (R > 0.85) but less strongly for MaxFm (R = 0.66). These results indicate that inertial sensors constitute a valid alternative for an optoelectronic measurement system when assessing dynamic stability in human locomotion, and may thus be used instead, which paves the way to studying gait stability during natural, everyday walking.
引用
收藏
页码:2588 / 2593
页数:6
相关论文
共 31 条
  • [1] [Anonymous], 1997, CAMBRIDGE NONLINEAR
  • [2] Is slow walking more stable?
    Bruijn, Sjoerd M.
    van Dieen, Jaap H.
    Meijer, Onno G.
    Beek, Peter J.
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (10) : 1506 - 1512
  • [3] Statistical precision and sensitivity of measures of dynamic gait stability
    Bruijn, Sjoerd M.
    van Dieen, Jaap H.
    Meijer, Onno G.
    Beek, Peter J.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2009, 178 (02) : 327 - 333
  • [4] Magnetic distortion in motion labs, implications for validating inertial magnetic sensors
    de Vries, W. H. K.
    Veeger, H. E. J.
    Baten, C. T. M.
    van der Helm, F. C. T.
    [J]. GAIT & POSTURE, 2009, 29 (04) : 535 - 541
  • [5] Kinematic variability and local dynamic stability of upper body motions when walking at different speeds
    Dingwell, JB
    Marin, LC
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (03) : 444 - 452
  • [6] Local dynamic stability versus kinematic variability of continuous overground and treadmill walking
    Dingwell, JB
    Cusumano, JP
    Cavanagh, PR
    Sternad, D
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (01): : 27 - 32
  • [7] Slower speeds in patients with diabetic neuropathy lead to improved local dynamic stability of continuous overground walking
    Dingwell, JB
    Cusumano, JP
    Sternad, D
    Cavanagh, PR
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (10) : 1269 - 1277
  • [8] Nonlinear time series analysis of normal and pathological human walking
    Dingwell, JB
    Cusumano, JP
    [J]. CHAOS, 2000, 10 (04) : 848 - 863
  • [9] The effects of sensory loss and walking speed on the orbital dynamic stability of human walking
    Dingwell, Jonathan B.
    Kang Hyun Gu
    Marin, Laura C.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (08) : 1723 - 1730
  • [10] Difference between local and orbital dynamic stability during human walking
    Dingwell, Jonathan B.
    Kang, Hyun Gu
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (04): : 586 - 593