Tacrolimus monitoring in renal transplantation: A comparison between high-performance liquid chromatography and immunoassay

被引:8
|
作者
Borrows, R
Chusney, G
Loucaidou, M
Singh, S
James, A
Stichbury, J
Van Tromp, J
Cairns, T
Griffith, M
Hakim, N
McLean, A
Palmer, A
Papalois, V
Taube, D
机构
[1] St Marys Hosp, Renal Unit, London W2 1NY, England
[2] St Marys Hosp, Transplant Unit, London W2 1NY, England
[3] St Marys Hosp, Brent Lab, London W2 1NY, England
关键词
D O I
10.1016/j.transproceed.2005.04.007
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
It is recommended that specific methods of tacrolimus monitoring rather than immunoassays, which overestimate tacrolimus levels, should be used in transplant recipients. Direct comparison of these techniques, however, has not been conducted in renal transplantation. In this study, 40 renal transplant recipients with tacrolimus monitoring by microparticle enzyme immunoassay (MEIA; target trough level 10 to 15 ng/mL) were compared with 40 patients monitored by high-performance liquid chromatography with tandem mass spectrometry (HPLC-MS; target trough level 8 to 13 ng/mL). All patients received anti CD25 antibody induction and mycophenolate mofetil in a steroid-sparing protocol. No differences were seen between MEIA and HPLC-MS groups in patient demographics. All patients were followed for 6 months. Patient survival was 100% in both groups; graft survival was 100% in the MEIA group and 97.5% in the HPLC-MS group. The groups did not differ in the number of dose changes required in the first 6 months or in the number of patients displaying tacrolimus levels within target range at 3 and 6 months. Delayed graft function occurred in 14 patients in the MEIA group and 12 patients in the HPLC-MS group (P = NS). Biopsy-proven acute rejection occurred in four patients in the MEIA group and one patient in the HPLC-MS group (P < .2). No differences were seen for the following parameters at 3 or 6 months: biopsy-proven tacrolimus nephrotoxicity, serum creatinine or estimated creatinine clearance, systolic or diastolic blood pressure, cholesterol, cytomegalovirus disease, posttransplant diabetes, or tremor. This study suggests that renal transplantation with HPLC-MS monitoring of tacrolimus is safe and effective.
引用
收藏
页码:1733 / 1735
页数:3
相关论文
共 50 条
  • [11] Phenytoin immunoassay measurements in serum samples from patients with renal insufficiency: Comparison with high-performance liquid chromatography
    Tutor-Crespo, Maria J.
    Hermida, Jesus
    Tutor, J. Carlos
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (02) : 119 - 123
  • [12] Performance Characteristics of a New Levetiracetam Immunoassay and Method Comparison With a High-Performance Liquid Chromatography Method
    Reineks, Edmunds Z.
    Lawson, Susan E.
    Lembright, Katherine E.
    Wang, Sihe
    THERAPEUTIC DRUG MONITORING, 2011, 33 (01) : 124 - 127
  • [13] Comparison of a high-performance liquid chromatography method for quantification of carbamazepine with chemiluminescent microparticle immunoassay
    Guerrero Garduno, Oscar
    Gonzalez-Esquivel, Dinora F.
    Escalante-Membrillo, Carmen
    Fernandez, Angeles
    Susana Rojas-Tome, Irma
    Jung Cook, Helgi
    Castro, Nelly
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (06) : 933 - 937
  • [14] High-performance liquid chromatography versus immunoassay for the measurement of sirolimus: Comparison of two methods
    Zochowska, D
    Bartlomiejczyk, I
    Kaminska, A
    Senatorski, G
    Paczek, L
    TRANSPLANTATION PROCEEDINGS, 2006, 38 (01) : 78 - 80
  • [15] Assay of teicoplanin in serum: comparison of high-performance liquid chromatography and fluorescence polarization immunoassay
    McCann, SJ
    White, LO
    Keevil, B
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2002, 50 (01) : 107 - 110
  • [16] THERAPEUTIC DRUG-MONITORING OF FLECAINIDE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COMPARISON WITH FLUORESCENCE POLARIZATION IMMUNOASSAY
    WOOLLARD, GA
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (02): : 409 - 419
  • [17] Immunosuppressive drug monitoring in renal transplantation: comparison between Elecsys® immunoassays and high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Robitaille, Robert
    Gingras, Marie-Eve
    Cossette, Chantal
    CLINICAL BIOCHEMISTRY, 2016, 49 (18)
  • [18] Therapeutic Drug Monitoring of Voriconazole: Comparison of Bioassay with High-Performance Liquid Chromatography
    Badiee, Parisa
    Hashemizadeh, Zahra
    Montaseri, Hashem
    JUNDISHAPUR JOURNAL OF MICROBIOLOGY, 2017, 10 (04)
  • [19] Comparison of high-performance liquid chromatography and enzyme-multiplied immunoassay technique to monitor mycophenolic acid in paediatric renal recipients
    Sabine Irtan
    Said Azougagh
    Caroline Monchaud
    Michel Popon
    Véronique Baudouin
    Évelyne Jacqz-Aigrain
    Pediatric Nephrology, 2008, 23 : 1859 - 1865
  • [20] Comparison of enzyme immunoassay and high-performance liquid chromatography determination of carbamazepine in human serum.
    Moreno, J
    Jaimes, O
    Dorantes, AM
    Nieves, E
    López, G
    Belmont, A
    Heinze, G
    SALUD MENTAL, 2001, 24 (05) : 12 - 16