A hybrid pulse shape discrimination technique with enhanced performance at neutron energies below 500 keV

被引:27
作者
Ambers, Scott D. [1 ]
Flaska, Marek [1 ]
Pozzi, Sara A. [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
Liquid scintillation detector; Pulse shape discrimination; Charge-integration; Reference-pulses;
D O I
10.1016/j.nima.2011.01.119
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A hybrid pulse shape discrimination (PSD) method is presented that combines a charge-integration PSD method with a reference-pulses PSD method. The reference-pulses PSD method uses detailed knowledge of the average, energy-dependent detector response to radiation. To obtain the reference-pulses, a large number of neutron and gamma-ray pulses was averaged in several pulse height regions. The reference neutron and gamma-ray pulses were then used in the new PSD method for the classification of a large number of measured pulses. The reference-pulses PSD method was applied below 70 keVee, whereas the standard charge-integration PSD method was used above 70 keVee. This new hybrid PSD method proves to be more accurate than the standard charge-integration PSD method for classification of neutrons and gamma rays. Specifically, the improvement is approximately 30% for neutrons in the smallest pulse height bin considered, which was between 20 and 30 keVee (corresponding to approximately 150 and 225 keV neutron energy deposited, respectively). For this pulse height bin. approximately 72% of the neutrons were correctly classified by the hybrid PSD method. The average number of correctly classified neutrons is approximately 88% for the hybrid PSD method between 20 and 100 keVee (corresponding to approximately 150 and 670 key neutron energy deposited, respectively) as opposed to 83% for the charge-integration PSD method. Published by Elsevier B.V.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 6 条
  • [1] VERSATILE PULSE SHAPE DISCRIMINATOR FOR CHARGED-PARTICLE SEPARATION AND ITS APPLICATION TO FAST-NEUTRON TIME-OF-FLIGHT SPECTROSCOPY
    ADAMS, JM
    WHITE, G
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (03): : 459 - 476
  • [2] Neutron and gamma-ray cross-correlation measurements of plutonium oxide powder
    Clarke, S. D.
    Flaska, M.
    Pozzi, S. A.
    Peerani, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (03) : 618 - 623
  • [3] PULSE SHAPE DISCRIMINATION - AN INVESTIGATION OF N-GAMMA DISCRIMINATION WITH RESPECT TO SIZE OF LIQUID SCINTILLATOR
    KALYNA, J
    TAYLOR, IJ
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1970, 88 (02): : 277 - +
  • [4] RESPONSE FUNCTIONS OF ORGANIC SCINTILLATORS TO HIGH-ENERGY NEUTRONS
    LOCKWOOD, JA
    CHEN, C
    FRILING, LA
    SWARTZ, D
    ONGE, RNS
    GALONSKY, A
    DOERING, RR
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1976, 138 (02): : 353 - 362
  • [5] AN ACCURATE PULSE-SHAPE DISCRIMINATOR FOR A WIDE RANGE OF ENERGIES
    SABBAH, B
    SUHAMI, A
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1968, 58 (01): : 102 - &
  • [6] SIMPLE PULSE-SHAPE DISCRIMINATION CIRCUIT
    SPERR, P
    SPIELER, H
    MAIER, MR
    EVERS, D
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1974, 116 (01): : 55 - 59