Determination of meloxicam in human plasma using a HPLC method with UV detection and its application to a pharmacokinetic study

被引:73
作者
Bae, Jung-Woo [1 ]
Kim, Mi-Jeong [1 ]
Jang, Choon-Gon [1 ]
Lee, Seok-Yong [1 ]
机构
[1] Sungkyunkwan Univ, Pharmacol Lab, Coll Pharm, Suwon 440746, South Korea
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 859卷 / 01期
关键词
meloxicam; HPLC; pharmacokinetics;
D O I
10.1016/j.jchromb.2007.09.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and sensitive high performance liquid chromatography method using UV detection (HPLC-UV) for the determination of meloxicam in human plasma was developed and validated. After extraction with diethyl ether, the chromatographic separation of meloxicam was carried out using a reverse phase Sunfire C-18 column (150 mm x 4.6 mm, 5 mu m) with a mobile phase of acetonitrile-20 mM potassium hydrogen phosphate (40:60, v/v, pH 3.5) and UV detection at a wavelength of 355 urn. The flow rate of mobile phase was 1.2 ml/min and the retention time of meloxicam and internal standard, piroxicam, was found to be 11.6 and 6.3 min, respectively. The calibration curve was linear within the concentration range, 10-2400 ng/ml (r(2) > 0.9999). The lower limit of quantification was 10 ng/ml. This method improved the sensitivity for the quantification of meloxicam in plasma using a HPLC-UV. The mean accuracy was 98-114%. The coefficient of variation (precision) in the intra- and inter-day validation was 1.6-4.3 and 2.4-7.3%, respectively. The pharmacokinetics of meloxicam was evaluated after administering an oral dose of 15 mg to I I healthy Korean subjects. The AUC(inf), C-max t(max) and t(1/2) were 42.4 +/- 13.2 mu g h/ml, 1445.7 +/- 305.5 ng/ml, 4.1 +/- 0.3 h and 22.0 +/- 4.9 h, respectively. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 10 条
[1]   LC determination and pharmacokinetics of meloxicam [J].
Dasandi, B ;
Shivaprakash ;
Saroj, H ;
Bhat, KM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (05) :999-1004
[2]   Clinical pharmacokinetics of meloxicam - A cyclo-oxygenase-2 preferential nonsteroidal anti-inflammatory drug [J].
Davies, NM ;
Skjodt, NM .
CLINICAL PHARMACOKINETICS, 1999, 36 (02) :115-126
[3]   ANTIINFLAMMATORY, ANALGESIC, ANTIPYRETIC AND RELATED PROPERTIES OF MELOXICAM, A NEW NONSTEROIDAL ANTIINFLAMMATORY AGENT WITH FAVORABLE GASTROINTESTINAL TOLERANCE [J].
ENGELHARDT, G ;
HOMMA, D ;
SCHLEGEL, K ;
UTZMANN, R ;
SCHNITZLER, C .
INFLAMMATION RESEARCH, 1995, 44 (10) :423-433
[4]  
Lee CH, 2000, J IMAGING SCI TECHN, V44, P308
[5]  
Medvedovici A, 2005, ARZNEIMITTELFORSCH, V55, P326
[6]  
Rigato HM, 2006, INT J CLIN PHARM TH, V44, P489
[7]  
SCHMID J, 1995, DRUG METAB DISPOS, V23, P1206
[8]   Development and validation of a new high-performance liquid chromatographic estimation method of meloxicam in biological samples [J].
Velpandian, T ;
Jaiswal, J ;
Bhardwaj, RK ;
Gupta, SK .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02) :431-436
[9]   Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma [J].
Wiesner, JL ;
de Jager, AD ;
Sutherland, FCW ;
Hundt, HKL ;
Swart, KJ ;
Hundt, AF ;
Els, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01) :115-121
[10]   Determination of meloxicam in human plasma by liquid chromatography-tandem mass spectrometry following transdermal administration [J].
Yuan, Yue ;
Chen, Xiaoyan ;
Zhong, Dafang .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :650-654