Comparison of coronary flow reserve estimated by dynamic radionuclide SPECT and multi-detector x-ray CT

被引:7
作者
Marini, Cecilia [1 ]
Seitun, Sara [2 ]
Zawaideh, Camilla [3 ]
Bauckneht, Matteo [4 ]
Morelli, Margherita Castiglione [2 ]
Ameri, Pietro [3 ]
Ferrarazzo, Giulia [4 ]
Budaj, Irilda [2 ]
Balbi, Manrico [3 ]
Fiz, Francesco [4 ]
Boccalini, Sara [2 ]
Pregliasco, Athena Galletto [2 ]
Buschiazzo, Ambra [4 ]
Saracco, Alice [5 ]
Bagnara, Maria Claudia [6 ]
Bruzzi, Paolo [7 ]
Brunelli, Claudio [3 ]
Ferro, Carlo [2 ]
Bezante, Gian Paolo [3 ]
Sambuceti, Gianmario [4 ]
机构
[1] CNR, Inst Bioimaging & Mol Physiol, Sect Genoa, Milan, Italy
[2] IRCCS AOU San Martino IST, Intervent Radiol, Genoa, Italy
[3] IRCCS AOU San Martino IST, Clin Cardiovasc Dis, Genoa, Italy
[4] IRCCS AOU San Martino IST, Nucl Med, Genoa, Italy
[5] Univ Genoa, DITEN, Genoa, Italy
[6] IRCCS AOU San Martino IST, Hlth Phys, Genoa, Italy
[7] IRCCS AOU San Martino IST, Epidemiol Unit, Genoa, Italy
关键词
Coronary flow reserve; x-ray computed tomography; SPECT; coronary artery disease; MYOCARDIAL BLOOD-FLOW; ARTERY-DISEASE; PERFUSION; STENOSIS; CONTRAST; HEART; QUANTIFICATION; AGREEMENT; COMMITTEE; TISSUE;
D O I
10.1007/s12350-016-0492-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Recent technical advances in multi-detector computed tomography (MDCT) allow for assessment of coronary flow reserve (CFR). We compared regional CFR by dynamic SPECT and by dynamic MDCT in patients with suspected or known coronary artery disease (CAD). Methods. Thirty-five patients, (29 males, mean age 69 years) with greater than average Framingham risk of CAD, underwent dipyridamole vasodilator stress imaging. CFR was estimated using dynamic SPECT and dynamic MDCT imaging in the same patients. Myocardial perfusion findings were correlated with obstructive CAD (>= 50% luminal narrowing) on CT coronary angiography (CA). Results. Mean CFR estimated by SPECT and MDCT in 595 myocardial segments was not different (1.51 +/- 0.46 vs. 1.50 +/- 0.37, p = NS). Correlation of segmental CFR by SPECT and MDCT was fair (r(2) = 0.39, p < 0.001). Bland-Altman analysis revealed that MDCT in comparison to SPECT systematically underestimated CFR in higher CFR ranges. By CTCA, 12 patients had normal CA, 11 had non-obstructive, and 12 had obstructive CAD. CFR by both techniques was significantly higher in territories of normal CA than in territories subtended by non-obstructive or obstructive CAD. SPECT CFR was also significantly different in territories subtended by non-obstructive and obstructive CAD, whereas MDCT CFR was not. Conclusion. Despite relative underestimation of high CFR values, MDCT CFR shows promise for assessing the pathophysiological significance of anatomic CAD.
引用
收藏
页码:1712 / 1721
页数:10
相关论文
共 30 条
  • [1] Feasibility of dynamic CT-based adenosine stress myocardial perfusion imaging to detect and differentiate ischemic and infarcted myocardium in an large experimental porcine animal model
    Bamberg, Fabian
    Hinkel, Rabea
    Marcus, Roy P.
    Baloch, Elisabeth
    Hildebrandt, Kristof
    Schwarz, Florian
    Hetterich, Holger
    Sandner, Torleif A.
    Schlett, Christopher L.
    Ebersberger, Ullrich
    Kupatt, Christian
    Hoffmann, Udo
    Reiser, Maximilian F.
    Theisen, Daniel
    Nikolaou, Konstantin
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (04) : 803 - 812
  • [2] Dynamic Myocardial CT Perfusion Imaging for Evaluation of Myocardial Ischemia as Determined by MR Imaging
    Bamberg, Fabian
    Marcus, Roy P.
    Becker, Alexander
    Hildebrandt, Kristof
    Bauner, Kerstin
    Schwarz, Florian
    Greif, Martin
    von Ziegler, Franz
    Bischoff, Bernhard
    Becker, Hans-Christoph
    Johnson, Thorsten R.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    Theisen, Daniel
    [J]. JACC-CARDIOVASCULAR IMAGING, 2014, 7 (03) : 267 - 277
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] 1ST-PASS ENTRY OF NONIONIC CONTRAST AGENT INTO THE MYOCARDIAL EXTRAVASCULAR SPACE - EFFECTS ON RADIOGRAPHIC ESTIMATES OF TRANSIT-TIME AND BLOOD-VOLUME
    CANTY, JM
    JUDD, RM
    BRODY, AS
    KLOCKE, FJ
    [J]. CIRCULATION, 1991, 84 (05) : 2071 - 2078
  • [5] 1,25-Dihydroxy vitamin D and coronary microvascular function
    Capitanio, Selene
    Sambuceti, Gianmario
    Giusti, Massimo
    Morbelli, Silvia
    Murialdo, Giovanni
    Garibotto, Giacomo
    Vera, Lara
    Ameri, Pietro
    Repetto, Barbara
    Naseri, Mehrdad
    Bossert, Irene
    Verardi, Maria Teresa
    Massollo, Michela
    Marini, Cecilia
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (02) : 280 - 289
  • [6] Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    Cerqueira, MD
    Weissman, NJ
    Dilsizian, V
    Jacobs, AK
    Kaul, S
    Laskey, WK
    Pennell, DJ
    Rumberger, JA
    Ryan, T
    Verani, MS
    [J]. CIRCULATION, 2002, 105 (04) : 539 - 542
  • [7] PERMEABILITY OF CAPILLARIES IN VARIOUS ORGANS AS DETERMINED BY USE OF INDICATOR DIFFUSION METHOD
    CRONE, C
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1963, 58 (04): : 292 - &
  • [8] Glover DK, 1997, CIRCULATION, V96, P2332
  • [9] PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE
    GOULD, KL
    LIPSCOMB, K
    HAMILTON, GW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) : 87 - 94
  • [10] CT stress perfusion imaging for detection of haemodynamically relevant coronary stenosis as defined by FFR
    Greif, Martin
    von Ziegler, Franz
    Bamberg, Fabian
    Tittus, Janine
    Schwarz, Florian
    D'Anastasi, Melvin
    Marcus, Roy P.
    Schenzle, Jan
    Becker, Christoph
    Nikolaou, Konstantin
    Becker, Alexander
    [J]. HEART, 2013, 99 (14) : 1004 - 1011