Altered saturation pulse with a high flip angle for venous saturation on 7 T time-of-flight magnetic resonance angiography

被引:0
作者
Kim, Sangwoo [1 ]
Lee, Chulhyun [2 ]
机构
[1] Daewon Univ Coll, Dept Radiol Sci, 316 Daehak Ro, Jecheon Si, Chungcheongbuk, South Korea
[2] Korea Basic Sci Inst, Ctr Res Equipment, 162 Yeongudanji Ro, Cheongju, Chungcheongbuk, South Korea
关键词
Presaturation pulse; Time-of-flight; Ultra-high field; Venous saturation; Magnetic resonance angiography; MR-ANGIOGRAPHY; LENTICULOSTRIATE ARTERIES; SPIN-ECHO; IN-VIVO; CONTRAST; TOF;
D O I
10.1186/s40543-021-00299-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study aimed to apply minimum-time variable-rate selective excitation (MinVER) to a presaturation pulse (PSP) with a high flip angle on 7 T time-of-flight magnetic resonance angiography (7T TOF-MRA), to attain a superior vessel-to-tissue contrast (VTCR), short acquisition time, and minor off-resonance effect. An altered PSP modified by using the 90 degrees flip angle (FA)-MinVER was implemented in the 7 T TOF-MRA, and its performance was evaluated with a signal profile and vessel-tissue contrast ratios and compared to the conventional PSP and 45 FA-TOF. The 90 FA-MinVER showed a similar signal profile to that of the conventional PSP and improved the vessel-tissue contrast ratios (0.313 +/- 0.80) compared to all conventional types (45 FA-TOF: 0.088 +/- 0.84, 90 FA-TOF: 0.203 +/- 0.72). Moreover, this noteworthy approach achieved substantially reduced total acquisition time (5 min and 55 s) with a short repeat-to-time (28 ms), indicating that at the 7 T TOF-MRA, the 90 FA-MinVER could be applied by default to suppress the venous signals regardless of individual human status and the specific absorption ratio constraint and with rapid imaging. Ultimately, its application could also help to observe subtle microvascular changes in the early stages and serve as key biomarkers in various vascular diseases.
引用
收藏
页数:7
相关论文
共 26 条
  • [1] Allison Jerry, 2015, AJR Am J Roentgenol, V205, pW140, DOI 10.2214/AJR.14.14173
  • [2] Brinjikji W., 2015, Journal of Vascular Diagnostics and Interventions, V3, P9
  • [3] Observation of the lenticulostriate arteries in the human brain in vivo using 7.0T MR angiography
    Cho, Zang-Hee
    Kang, Chang-Ki
    Han, Jae-Yong
    Kim, Sang-Hoon
    Kim, Kyoung-Nam
    Hong, Suk-Min
    Park, Cheol-Wan
    Kim, Young-Bo
    [J]. STROKE, 2008, 39 (05) : 1604 - 1606
  • [4] VARIABLE-RATE SELECTIVE EXCITATION
    CONOLLY, S
    NISHIMURA, D
    MACOVSKI, A
    GLOVER, G
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 440 - 458
  • [5] A REDUCED POWER SELECTIVE ADIABATIC SPIN-ECHO PULSE SEQUENCE
    CONOLLY, S
    GLOVER, G
    NISHIMURA, D
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) : 28 - 38
  • [6] Deniz Cem M, 2019, Top Magn Reson Imaging, V28, P159, DOI 10.1097/RMR.0000000000000204
  • [7] Comparison of 3.0-and 1.5-T three-dimensional time-of-flight MR angiography in Moyamoya disease: Preliminary experience
    Fushimi, Y
    Miki, Y
    Kikuta, K
    Okada, T
    Kanagaki, M
    Yamamoto, A
    Nozaki, K
    Hashimoto, N
    Hanakawa, T
    Fukuyama, H
    Togashi, K
    [J]. RADIOLOGY, 2006, 239 (01) : 232 - 237
  • [8] BROAD-BAND NUCLEAR MAGNETIC-RESONANCE PULSES WITH TWO-DIMENSIONAL SPATIAL SELECTIVITY
    HARDY, CJ
    CLINE, HE
    [J]. JOURNAL OF APPLIED PHYSICS, 1989, 66 (04) : 1513 - 1516
  • [9] Variable-rate selective excitation for rapid MRI sequences
    Hargreaves, BA
    Cunningham, CH
    Nishimura, DG
    Conolly, SM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 590 - 597
  • [10] Noninvasive Depiction of the Lenticulostriate Arteries with Time-of-Flight MR Angiography at 7.0 T
    Hendrikse, Jeroen
    Zwanenburg, Jaco J.
    Visser, Fredy
    Takahara, Taro
    Luijten, Peter
    [J]. CEREBROVASCULAR DISEASES, 2008, 26 (06) : 624 - 629