Tandem mass spectrometry (ICP-MS/MS) for overcoming molybdenum oxide interferences on Cd determination in milk

被引:41
作者
Amais, Renata S. [1 ]
Virgilio, Alex [2 ]
Schiavo, Daniela [3 ]
Nobrega, Joaquim A. [2 ]
机构
[1] Univ Sao Paulo, Ctr Nucl Energy Agr, BR-13416000 Piracicaba, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, BR-13565905 Sao Carlos, SP, Brazil
[3] Agilent Technol Brazil, BR-06460040 Barueri, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Inductively coupled plasma; Polyatomic interferences; Food; Tandem mass spectrometry; CADMIUM; MS;
D O I
10.1016/j.microc.2015.01.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is well known that molybdenum oxides affect Cd determination by inductively coupled plasma mass spectrometry (ICP-MS). It is proposed here a procedure for simultaneous determination of Cd and Mo. The effectiveness of the ICP-MS with tandem configuration (ICP-MS/MS) using octopole reaction system (ORS3) pressurized with oxygen gas and MS/MS mode to overcome Mo oxide-based interferences on Cd determination was evaluated. Cadmium was determined as free atom ion and Mo was determined as MoO2+ employing a 0.5 mL min(-1) oxygen gas flow rate into the ORS3. Non-fat and whole milk powder certified reference materials (NIST SRM 8435 and SRM 1549) were used for checking the accuracy of the proposed procedure. The microwave-assisted digestion was carried out using diluted nitric acid solution (2.6 mol L-1 HNO3) and hydrogen peroxide (30% m m(-1)). According to Student's t-test, reference and determined values were in agreement at a 95% confidence level, except for Cd-111 and Cd-113 in SRM 1549. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 14 条
[1]  
Agilent Vapor Generation Accessory VGA 77 User's Guide, 2012, AG TECHN INC PUBL
[2]   Determination of P, S and Si in biodiesel, diesel and lubricating oil using ICP-MS/MS [J].
Amais, Renata S. ;
Amaral, Clarice D. B. ;
Fialho, Lucimar L. ;
Schiavo, Daniela ;
Nobrega, Joaquim A. .
ANALYTICAL METHODS, 2014, 6 (13) :4516-4520
[3]   Accurate determination of S in organic matrices using isotope dilution ICP-MS/MS [J].
Balcaen, Lieve ;
Woods, Glenn ;
Resano, Martin ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (01) :33-39
[4]  
Becker J. S., 2007, INORGANIC MASS SPECT
[5]   Rapid multi-element analysis of groundwater by high-resolution inductively coupled plasma mass spectrometry [J].
Cheng, Z ;
Zheng, Y ;
Mortlock, R ;
van Geen, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) :512-518
[6]   Determination of trace level cadmium in SRM 3280 Multivitamin/Multielement Tablets via isotope dilution inductively coupled plasma mass spectrometry [J].
Christopher, Steven J. ;
Thompson, Robert Q. .
TALANTA, 2013, 116 :18-25
[7]   Determination of trace elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry - Developing of a method with a desolvating system nebulizer [J].
D'Ilio, S. ;
Violante, N. ;
Caimi, S. ;
Di Gregorio, M. ;
Petrucci, F. ;
Senofonte, O. .
ANALYTICA CHIMICA ACTA, 2006, 573 :432-438
[8]   Determination of As, Cd, Hg and Pb in herbs using slurry sampling electrothermal vaporisation inductively coupled plasma mass spectrometry [J].
Lin, Mei-Ling ;
Jiang, Shiuh-Jen .
FOOD CHEMISTRY, 2013, 141 (03) :2158-2162
[9]   Understanding the meaning of accuracy, trueness and precision [J].
Menditto, Antonio ;
Patriarca, Marina ;
Magnusson, Bertil .
ACCREDITATION AND QUALITY ASSURANCE, 2007, 12 (01) :45-47
[10]   Recognizing and overcoming analytical error in the use of ICP-MS for the determination of cadmium in breakfast cereal and dietary supplements [J].
Murphy, Karen E. ;
Vetter, Thomas W. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (13) :4579-4588