Effect of size on the failure of FRP strengthened reinforced concrete beams
被引:0
作者:
Leung, CKY
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R ChinaHong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R China
Leung, CKY
[1
]
Chen, ZF
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R ChinaHong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R China
Chen, ZF
[1
]
Lee, SKL
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R ChinaHong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R China
Lee, SKL
[1
]
Tang, JM
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R ChinaHong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R China
Tang, JM
[1
]
机构:
[1] Hong Kong Univ Sci & Technol, Dept Civil Engn, Kowloon, Hong Kong, Peoples R China
来源:
ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS
|
2002年
The bonding of fiber reinforced plastic (FRP) plates is an effective and efficient method to improve the bending capacity of concrete beams. In the literature, various design methodologies have been proposed and several of them have been found to compare well with test data or to provide reasonable lower bounds. However, almost all the experimental data are obtained from laboratory-size specimens that are several times smaller than members in real structures. On close examination, different design methodologies exhibit significantly different trends of load capacity vs member size. With no test results on larger specimens, it is not possible to determine which approach is more appropriate for designing real size members. In this investigation, geometrically similar reinforced concrete beams with steel ratio of 0.01, and depth ranging from 0.2 in to 0.8 in were prepared. Some RC beams were tested as control while others were retrofitted with 2 to 8 layers of Carbon fiber reinforced plastic (CFRP) sheets to achieve the same CFRP/concrete area ratio. All the beams were tested to failure to investigate the variation of failure load with member size. The results of the present investigation are expected to provide useful information for (i) the extrapolation of small specimen results to large members of practical size, and (ii) the checking of theoretical models for design.
机构:
Department of Civil Engineering, University of Hong KongDepartment of Civil Engineering, University of Hong Kong
Smith S.T.
Kim S.J.
论文数: 0引用数: 0
h-index: 0
机构:
Department of Civil Engineering, University of Hong Kong
Centre for Built Infrastructure Research, University of Technology SydneyDepartment of Civil Engineering, University of Hong Kong
机构:
Natl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, ArgentinaNatl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, Argentina
Sfer, Domingo
Luccioni, Bibiana
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, Argentina
Consejo Nacl Invest Cient & Tecn, Bs As, ArgentinaNatl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, Argentina
机构:
Department of Civil Engineering, University of Hong KongDepartment of Civil Engineering, University of Hong Kong
Smith S.T.
Kim S.J.
论文数: 0引用数: 0
h-index: 0
机构:
Department of Civil Engineering, University of Hong Kong
Centre for Built Infrastructure Research, University of Technology SydneyDepartment of Civil Engineering, University of Hong Kong
机构:
Natl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, ArgentinaNatl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, Argentina
Sfer, Domingo
Luccioni, Bibiana
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, Argentina
Consejo Nacl Invest Cient & Tecn, Bs As, ArgentinaNatl Univ Tucuman, Struct Inst, RA-4000 San Miguel De Tucuman, Argentina