Correlation between bone volume fraction in posterior implant area and initial implant stability

被引:8
作者
Tian, Tian [1 ]
Liu, Hong-hong [1 ]
Zhang, Zhi-hong [1 ]
Han, Qian [1 ]
Chen, Jia [1 ]
Lv, Jing [1 ]
机构
[1] Univ Sci & Technol China, Div Life Sci & Med, Affiliated Hosp 1, Hefei, Anhui, Peoples R China
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2022年 / 133卷 / 04期
关键词
QUALITY; DESIGN;
D O I
10.1016/j.oooo.2021.08.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. Bone volume fraction (BV/TV) was used as a quantitative indicator of bone mineral density (BMD) in the posterior dental implant area, and the relationship between it and the initial stability of the implant was analyzed. Methods. 53 patients with posterior dental implantation were selected. Remove the bone fragments from the planting area and put them in the formalin solution. Then, the implant was placed after the operator prepared the hole step by step. Peak Insertion torque value (ITV) and Implant stability quotient (ISQ) were recorded. The BV/TV of the bone fragments was measured by Image pro Plus6.0. The correlation between it and ITV and ISQ was analyzed. Results. BV/TV was correlated with ITV and ISQ in the posterior dental planting area (r=0.862, r=0.832, P < 0.05). The correlation of the parameters in the posterior part of maxilla was higher than that in the mandible. There were significant differences in BV/TV, ITV, and ISQ between the mandible and maxilla, and the implant area of the mandible was higher than that of the maxilla. Conclusion. BV/TV can provide an objective index for BMD in the implant area, which has an important influence on the evaluation of the initial stability of the implant.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
[41]   Correlation of Radiographic Fractal Analysis with Implant Insertion Torque in a Rabbit Trabecular Bone Model [J].
Veltri, Mario ;
Ferrari, Marco ;
Balleri, Piero .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) :108-114
[42]   Human Mandibular Trabecular Bone Density Correlation With Mechanical Strength: Implications for Implant Dentistry [J].
Kido, Hirofumi ;
Schulz, Eloy E. ;
Kakura, Kae ;
Yamamoto, Katsuki ;
Morinaga, Kenzo ;
Matsuura, Masaro .
IMPLANT DENTISTRY, 2011, 20 (04) :323-326
[43]   Relationship between Cortical Bone Thickness and Cancellous Bone Density at Dental Implant Sites in the Jawbone [J].
Wang, Shiuan-Hui ;
Shen, Yen-Wen ;
Fuh, Lih-Jyh ;
Peng, Shin-Lei ;
Tsai, Ming-Tzu ;
Huang, Heng-Li ;
Hsu, Jui-Ting .
DIAGNOSTICS, 2020, 10 (09)
[44]   Clinical methodologies for achieving primary dental implant stability The effects of alveolar bone density [J].
Cavallaro, John, Jr. ;
Greenstein, Ben ;
Greenstein, Gary .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (11) :1366-1372
[45]   Effect of implant design on the initial biomechanical stability of two self-tapping dental implants [J].
Hsieh, Min-Chieh ;
Huang, Chang-Hung ;
Lin, Chun-Li ;
Hsu, Ming-Lun .
CLINICAL BIOMECHANICS, 2020, 74 :124-130
[46]   Correlation between Initial BIC and the Insertion Torque/Depth Integral Recorded with an Instantaneous Torque-Measuring Implant Motor: An in vivo Study [J].
Cappare, Paolo ;
Vinci, Raffaele ;
Di Stefano, Danilo Alessio ;
Traini, Tonino ;
Pantaleo, Giuseppe ;
Gherlone, Enrico Felice ;
Gastaldi, Giorgio .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 :E613-E620
[47]   Influence of different surgical techniques on primary implant stability in the posterior maxilla: a randomized controlled clinical trial [J].
Olmedo-Gaya, Maria-Victoria ;
Romero-Olid, Maria-Nuria ;
Ocana-Peinado, Francisco M. ;
Vallecillo-Rivas, Marta ;
Vallecillo, Cristina ;
Reyes-Botella, Candela .
CLINICAL ORAL INVESTIGATIONS, 2023, 27 (07) :3499-3508
[48]   Influence of Crown-Implant Ratio and Implant Inclination on Marginal Bone Loss around Dental Implants Supporting Single Crowns in the Posterior Region: A Retrospective Clinical Study [J].
Rahim, Maha Abdul ;
Khan, Kashmala ;
Chrcanovic, Bruno Ramos .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (09)
[49]   Correlation Between Bone Density and Instantaneous Torque at Implant Site Preparation: A Validation on Polyurethane Foam Blocks of a Device Assessing Density of Jawbones [J].
Di Stefano, Danilo Alessio ;
Arosio, Paolo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) :E128-E135
[50]   Comparative Evaluation of Two Implant Designs Based on Bone Loss and Stability with Early Loading Method [J].
Gasthi, Anjaneyulu ;
Rao, Udayagiri Madhusudhana ;
Alharethi, Naji ;
Awinashe, Vaibhav ;
Sayed, Arshad Jamal ;
Parihar, Anuj Singh ;
Manas, Abhigyan .
JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 :S885-S887