Correlation between bone volume fraction in posterior implant area and initial implant stability

被引:6
|
作者
Tian, Tian [1 ]
Liu, Hong-hong [1 ]
Zhang, Zhi-hong [1 ]
Han, Qian [1 ]
Chen, Jia [1 ]
Lv, Jing [1 ]
机构
[1] Univ Sci & Technol China, Div Life Sci & Med, Affiliated Hosp 1, Hefei, Anhui, Peoples R China
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2022年 / 133卷 / 04期
关键词
QUALITY; DESIGN;
D O I
10.1016/j.oooo.2021.08.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. Bone volume fraction (BV/TV) was used as a quantitative indicator of bone mineral density (BMD) in the posterior dental implant area, and the relationship between it and the initial stability of the implant was analyzed. Methods. 53 patients with posterior dental implantation were selected. Remove the bone fragments from the planting area and put them in the formalin solution. Then, the implant was placed after the operator prepared the hole step by step. Peak Insertion torque value (ITV) and Implant stability quotient (ISQ) were recorded. The BV/TV of the bone fragments was measured by Image pro Plus6.0. The correlation between it and ITV and ISQ was analyzed. Results. BV/TV was correlated with ITV and ISQ in the posterior dental planting area (r=0.862, r=0.832, P < 0.05). The correlation of the parameters in the posterior part of maxilla was higher than that in the mandible. There were significant differences in BV/TV, ITV, and ISQ between the mandible and maxilla, and the implant area of the mandible was higher than that of the maxilla. Conclusion. BV/TV can provide an objective index for BMD in the implant area, which has an important influence on the evaluation of the initial stability of the implant.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [1] The Correlation Between Immediate Implant Insertion Torque and Implant Stability Quotient
    Levin, Barry P.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (06) : 833 - 840
  • [2] Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis
    Falco, Antonello
    Berardini, Marco
    Trisi, Paolo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 824 - 830
  • [3] Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size
    Ivanova, Vasilena
    Chenchev, Ivan
    Zlatev, Stefan
    Mijiritsky, Eitan
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [4] Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets
    Cehreli, Murat Cavit
    Kokat, Ali Murat
    Comert, Ayhan
    Akkocaoglu, Murat
    Tekdemir, Ibrahim
    Akca, Kwanc
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) : 1163 - 1169
  • [5] Initial stability and bone strain evaluation of the immediately loaded dental implant: an in vitro model study
    Huang, Heng-Li
    Chang, Yin-Yu
    Lin, Dan-Jae
    Li, Yu-Fen
    Chen, Kuan-Ting
    Hsu, Jui-Ting
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (07) : 691 - 698
  • [6] Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types
    Howashi, Miori
    Tsukiyama, Yoshihiro
    Ayukawa, Yasunori
    Isoda-Akizuki, Kei
    Kihara, Masafumi
    Imai, Yu
    Sogo, Motofumi
    Koyano, Kiyoshi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 107 - 116
  • [7] Correlating implant stability to bone structure
    Roze, Julie
    Babu, Stephanie
    Saffarzadeh, Afchine
    Gayet-Delacroix, Marie
    Hoornaert, Alain
    Layrolle, Pierre
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) : 1140 - 1145
  • [8] Correlation between Periotest value and implant stability quotient: a systematic review
    Rodrigues, Alana Semenzin
    Neto, Clovis Lamartine de Moraes Melo
    Januzzi, Marcella Santos
    dos Santos, Daniela Micheline
    Goiato, Marcelo Coelho
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024, 69 (01): : 1 - 10
  • [9] Associations between cortical bone-to-implant contact and microstructure derived from CBCT and implant primary stability
    Feng, Lan
    Chen, Haida
    Chen, Ziyun
    Chen, Yan
    Gu, Xinhua
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (03) : 243 - 253
  • [10] Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study
    Lee, Jungwon
    Lim, Young-Jun
    Ahn, Jin-Soo
    Kim, Bongju
    Baek, Yeon-Wha
    Lim, Bum-Soon
    PLOS ONE, 2024, 19 (05):