Mechanical and durability characteristics of flyash and GGBFS based polypropylene fibre reinforced geopolymer concrete

被引:12
作者
Murthy, Shreyas S. [1 ]
Patil, Nayana N. [1 ]
机构
[1] Ramaiah Univ Appl Sci, Bangalore 560058, India
关键词
Geopolymer concrete; Flyash; GGBFS; Polypropylene fibers; CFST columns; PERFORMANCE;
D O I
10.1016/j.matpr.2021.10.036
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The construction sector has been under scrutiny since a long time for its influence in addition to air pollution and global warming. Due to this development and use of sustainable materials such as geopolymers and innovative methods such as CFST for construction has been the forefront of research during recent times. This study investigates the durability and mechanical characteristics of Polypropylene (PP) fiber reinforced geopolymer concrete and its use in Concrete in-Filled Steel Tube (CFST) columns. For the experimental study, PP fibers were added by varying proportions as 0.5%, 1% and 1.5% by mass of binder. The results showed that the mix with 1% PP fibers had the best mechanical and durability characteristics. The square CFST columns of 109 mm x 109 mm x 470 mm dimensions showed consistent failure due to edge weakness. A maximum average axial compressive strength of 43.27 MPa was obtained for the CFST columns.Copyright (c) 2022 Elsevier Ltd. All rights reserved. Selection and peer-review under responsibility of the scientific committee of the Third International Conference on Recent Advances in Materials and Manufacturing 2021
引用
收藏
页码:18 / 24
页数:7
相关论文
共 12 条
[1]   Axial performance of GGBFS concrete filled steel tubes [J].
Ahmad, Subhan ;
Kumar, Ajay ;
Kumar, Kamal .
STRUCTURES, 2020, 23 :539-550
[2]   Experimental study on fly ash and lead smelter slag-based geopolymer concrete columns [J].
Albitar, M. ;
Ali, M. S. Mohamed ;
Visintin, P. .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 141 :104-112
[3]  
Aleem M.A., 2012, Indian J. Sci. Technol, V5, P2299, DOI DOI 10.17485/IJST/2012/V5I3.8
[4]  
Aleem M.A., 2012, International Journal of Engineering Sciences and Emerging Technologies, V1, P118, DOI [DOI 10.7323/IJESET/V1_I2_14, DOI 10.7323/IJESET/V1]
[5]  
Hardjito D, 2004, ACI MATER J, V101, P467
[6]  
Mohammadi B., 2013, Development of concrete water absorption testing for quality control (Doctoral dissertation
[7]   Assessment of Na2SiO3 to NaOH ratio impact on the performance of polypropylene fiber-reinforced geopolymer composites [J].
Mohseni, Ehsan .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 186 :904-911
[8]  
Rangan BV., 2014, Indian Concr. J, V88, P41
[9]  
S. R, 2020, EFF SHAP CONCR INF S
[10]  
Tao Z., 2018, INT J HIGH RISE BUIL, V7, P327, DOI [10.21022/IJHRB.2018.7.4.327, DOI 10.21022/IJHRB.2018.7.4.327]