Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study

被引:19
作者
Chen, Bixia [1 ,2 ]
Schoemberg, Tobias [1 ,2 ]
Kraff, Oliver [1 ]
Dammann, Philipp [1 ,2 ]
Bitz, Andreas K. [1 ,3 ]
Schlamann, Marc [4 ,5 ]
Quick, Harald H. [1 ,6 ]
Ladd, Mark E. [1 ,3 ]
Sure, Ulrich [2 ]
Wrede, Karsten H. [1 ,2 ]
机构
[1] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
[2] Univ Hosp Essen, Dept Neurosurg, Essen, Germany
[3] German Canc Res Ctr, Med Phys Radiol, Heidelberg, Germany
[4] Univ Hosp Essen, Inst Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[5] Univ Hosp Giessen, Dept Neuroradiol, Giessen, Germany
[6] Univ Hosp Essen, High Field & Hybrid MR Imaging, Essen, Germany
关键词
Magnetic resonance imaging; 7; Tesla; Titanium cranial fixation plates; Postoperative; Craniotomy; NEUROSURGICAL IMPLANTS; MRI;
D O I
10.1007/s10334-016-0548-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T-1-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T-2-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Minor artifacts occurred around the CFPs in MPRAGE and T-2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 26 条
  • [1] [Anonymous], 2009, P INT SOC MAGN RESON
  • [2] Bitz A.K., 2011, Proceedings of the International Society for Magnetic Resonance in Medicine, P490
  • [3] Metallic neurosurgical implants for cranial reconstruction and fixation: assessment of magnetic field interactions, heating and artefacts at 3.0 Tesla
    Cunningham, AS
    Harding, S
    Chatfield, DA
    Hutchinson, P
    Carpenter, TA
    Pickard, JD
    Menon, DK
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2005, 19 (02) : 167 - 172
  • [4] Susceptibility weighted magnetic resonance imaging of cerebral cavernous malformations: prospects, drawbacks, and first experience at ultra-high field strength (7-Tesla) magnetic resonance imaging
    Dammann, Philipp
    Barth, Markus
    Zhu, Yuan
    Maderwald, Stefan
    Schlamann, Marc
    Ladd, Mark E.
    Sure, Ulrich
    [J]. NEUROSURGICAL FOCUS, 2010, 29 (03) : 1 - 7
  • [5] Three-dimensional susceptibility-weighted imaging at 7 T using fractal-based quantitative analysis to grade gliomas
    Di Ieva, Antonio
    Goed, Sabine
    Grabner, Guenther
    Grizzi, Fabio
    Sherif, Camillo
    Matula, Christian
    Tschabitscher, Manfred
    Trattnig, Siegfrid
    [J]. NEURORADIOLOGY, 2013, 55 (01) : 35 - 40
  • [6] Evaluation of 39 medical implants at 7.0T
    Feng, David X.
    Mccauley, Joseph P.
    Morgan-Curtis, Fea K.
    Salam, Redoan A.
    Pennell, David R.
    Loveless, Mary E.
    Dula, Adrienne N.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1056)
  • [7] Longitudinal brain imaging of five malignant glioma patients treated with bevacizumab using susceptibility-weighted magnetic resonance imaging at 7 T
    Grabner, Guenther
    Noebauer, Iris
    Elandt, Katarzyna
    Kronnerwetter, Claudia
    Woehrer, Adelheid
    Marosi, Christine
    Prayer, Daniela
    Trattnig, Siegfried
    Preusser, Matthias
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (01) : 139 - 147
  • [8] International Electrotechnical Commission, 2015, 606012332015 INT EL
  • [9] Fast 3D radiofrequency field mapping using echo-planar imaging
    Jiru, F.
    Klose, U.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1375 - 1379
  • [10] Advanced Magnetic Resonance Imaging of the Physical Processes in Human Glioblastoma
    Kalpathy-Cranner, Jayashree
    Gerstner, Elizabeth R.
    Emblen, Kyrre E.
    Andronesi, Ovidiu C.
    Rosen, Bruce
    [J]. CANCER RESEARCH, 2014, 74 (17) : 4622 - 4637