Improving injection precision in packed-column supercritical fluid chromatography

被引:5
作者
Coym, JW [1 ]
Chester, TL [1 ]
机构
[1] Procter & Gamble Co, Miami Valley Labs, Cincinnati, OH 45253 USA
来源
JOURNAL OF SEPARATION SCIENCE | 2003年 / 26卷 / 6-7期
关键词
supercritical fluid chromatography; injection; precision; reproducibility;
D O I
10.1002/jssc.200390083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is often observed that peak area precision in packed column supercritical fluid chromatography (pSFC) is rather poor when compared to values obtained in HPLC. Since the valves used for sample introduction in both techniques are identical, it is reasonable to expect that injection precision should be similar, especially when full-loop injections are performed. We found that in pSFC the evaporation of the mobile phase from the loop, when decompressed just prior to sample loading, contributes strongly to injection problems. However, these problems can be avoided if the injection valve, sample loop, and associated port tubes are entirely filled with liquid before the sample solution is loaded into the sample loop. By being mindful of the sequence of events that occurs during a full-loop injection, and by taking into account both the compressible nature and volatility of pSFC mobile phases and the geometry of the injection device, injection precision in pSFC can be comparable to that observed in HPLC.
引用
收藏
页码:609 / 613
页数:5
相关论文
共 12 条
[1]   A SIMPLE LARGE-VOLUME INJECTION SYSTEM WITH A SOLID-PHASE SAMPLE LOOP FOR PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
ARNOLD, M ;
KLEIBOHMER, W .
CHROMATOGRAPHIA, 1994, 39 (9-10) :612-618
[2]  
Arnold M, 1995, HRC-J HIGH RES CHROM, V18, P721
[3]  
BERGER TA, 1997, SUPERCRITICAL FLUID, pCH2
[4]   Chromatography from the mobile-phase perspective [J].
Chester, TL .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :A165-A169
[5]   IMPROVEMENT IN THE SOLVENT EVAPORATION INJECTION TECHNIQUE FOR PREPARATIVE SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
CRETIER, G ;
MAJDALANI, R ;
NEFFATI, J ;
ROCCA, JL .
CHROMATOGRAPHIA, 1994, 38 (5-6) :330-336
[6]  
DEAN TA, 1989, HRC-J HIGH RES CHROM, V12, P773
[7]   Characterization of a solventless injection interface for supercritical fluid chromatography [J].
Gao, JY ;
Kibbey, CE .
CHROMATOGRAPHIA, 2000, 51 (11-12) :747-755
[8]  
Greibrokk T, 1999, ANALUSIS, V27, P673
[9]   LARGE-VOLUME INJECTION FOR PREPARATIVE SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
HIRATA, Y ;
KAWAGUCHI, Y ;
KITANO, K .
CHROMATOGRAPHIA, 1995, 40 (1-2) :42-46
[10]  
KIRSCHNER CH, 1993, J HIGH RES CHROMATOG, V16, P73