Development and validation of an automated latex-enhanced immunoassay for prealbumin

被引:1
作者
Holownia, P
Newman, DJ
Thakkar, H
Bedzyk, WD
Crane, H
Olabiran, Y
Davey, CL
Price, CP
机构
[1] St Bartholomews & Royal London Sch Med & Dent, Dept Clin Biochem, London E1 2AD, England
[2] Wilmington Inc, Dade Int, Glasgow Site, Newark, DE 19898 USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The measurement of circulating prealbumin has been shown to be clinically useful in the assessment of nutritional status, both as an initial screen and in the monitoring of nutritional recovery. We describe a fully automated, noncompetitive, homogenous, light-scattering immunoassay that has been developed for this analyte on a Dimension(R) (Dade) analyzer. A sheep anti-prealbumin IgG fraction was covalently coupled to 40-nm chloromethyl styrene particles and, after the addition of sample, polyethylene glycol-assisted immunoagglutination was monitored by turbidimetry. The prealbumin working assay range was 8-550 mg/L at a sample volume of 2 mu L and a reaction time of 6.5 min. When data were analyzed using ANOVA, total and within-run assay imprecision values (CVs) were 1-5%, and calibration and reagent stabilities were in excess of 40 days. Mean analytical recoveries were 102% +/- 4% (SD), and there was no lack of parallelism. Hemolysis, lipemia, and bilirubin did not interfere. Both plasma anticoagulated with heparin or EDTA and serum from plain or serum-separation tubes were acceptable as sample matrices. Comparison with the Beekman Array(R) method gave a Passing and Bablok regression of: Dimension analyzer = 1.01Beckman + 7.1 (n = 103), using a common calibrator. We conclude that the prealbumin method is appropriate for clinical use according to the analytical criteria used in this study.
引用
收藏
页码:1316 / 1324
页数:9
相关论文
共 50 条
[31]   Evaluation of latex-enhanced turbidimetric reagents for measuring free immunoglobulin light-chains on the Roche COBAS Integra 400 automated analyser [J].
Showell, P. J. ;
Lynch, E. A. ;
Johnson-Brett, B. ;
Mead, G. P. ;
Bradwell, A. R. .
CLINICAL CHEMISTRY, 2007, 53 (06) :A109-A109
[32]   A sensitive, latex-enhanced assay for IgG4 on the binding site MININEPHTM. [J].
Overton, J ;
Lynch, L ;
Carr-Smith, HD ;
Bradwell, AR .
CLINICAL CHEMISTRY, 2002, 48 (06) :A37-A37
[33]   Evaluation of a latex-enhanced IgD assay for the Dade-Behring BN™II. [J].
Showell, PJ ;
Mitchell, F ;
Carr-Smith, HD ;
Bradwell, AR .
CLINICAL CHEMISTRY, 2005, 51 :A74-A75
[34]   Development and applications of a new immunoassay method: Latex piezoelectric immunoassay [J].
Kurosawa, S ;
Muratsugu, M ;
Ghourchian, HO ;
Kamo, N .
IMMUNOCHEMICAL TECHNOLOGY FOR ENVIRONMENTAL APPLICATIONS, 1997, 657 :185-196
[35]   Determination of serum lipoprotein lipase using a latex particle-enhanced turbidimetric immunoassay with an automated analyzer [J].
Machida, Tetsuo ;
Miyashita, Kazuya ;
Sone, Takuya ;
Tanaka, Sayori ;
Nakajima, Katsuyuki ;
Saito, Masayuki ;
Stanhope, Kimber ;
Havel, Peter ;
Sumino, Hiroyuki ;
Murakami, Masami .
CLINICA CHIMICA ACTA, 2015, 442 :130-135
[36]   Evaluation of a new high-sensitive ferritin latex-enhanced TIA assay. [J].
Kamata, S ;
Yamazaki, T ;
Sekine, S ;
Mutou, N .
CLINICAL CHEMISTRY, 2002, 48 (06) :A36-A36
[37]   Evaluation of latex-enhanced turbidimetric reagents for measuring IgG subclasses on the Roche Modular P [J].
Carr-Smith, HD ;
Overton, J ;
Rai, B ;
Mayne, J ;
Bradwell, AR .
CLINICAL CHEMISTRY, 2004, 50 (06) :A55-A55
[38]   Evaluation of an automated, latex-enhanced turbidimetric D-dimer test (advanced D-dimer) and usefulness in the exclusion of acute thomboembolic disease [J].
Wilson, DB ;
Gard, KM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 120 (06) :930-937
[39]   Evaluation of latex-enhanced IgG3 reagents on the Roche Mira and Hitachi analysers [J].
Showell, PJ ;
Mattters, DJ ;
Mitchell, F ;
Carr-Smith, HD ;
Bradwell, AR .
CLINICAL CHEMISTRY, 2004, 50 (06) :A51-A51
[40]   Latex-enhanced immunoassay D-dimer and blood gases can exclude pulmonary embolism in low-risk patients presenting to an acute care setting [J].
Hlavac, M ;
Cook, J ;
Ojala, R ;
Town, I ;
Beckert, L .
CHEST, 2005, 128 (04) :2183-2189