Development and validation of an automated latex-enhanced immunoassay for prealbumin

被引:1
作者
Holownia, P
Newman, DJ
Thakkar, H
Bedzyk, WD
Crane, H
Olabiran, Y
Davey, CL
Price, CP
机构
[1] St Bartholomews & Royal London Sch Med & Dent, Dept Clin Biochem, London E1 2AD, England
[2] Wilmington Inc, Dade Int, Glasgow Site, Newark, DE 19898 USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The measurement of circulating prealbumin has been shown to be clinically useful in the assessment of nutritional status, both as an initial screen and in the monitoring of nutritional recovery. We describe a fully automated, noncompetitive, homogenous, light-scattering immunoassay that has been developed for this analyte on a Dimension(R) (Dade) analyzer. A sheep anti-prealbumin IgG fraction was covalently coupled to 40-nm chloromethyl styrene particles and, after the addition of sample, polyethylene glycol-assisted immunoagglutination was monitored by turbidimetry. The prealbumin working assay range was 8-550 mg/L at a sample volume of 2 mu L and a reaction time of 6.5 min. When data were analyzed using ANOVA, total and within-run assay imprecision values (CVs) were 1-5%, and calibration and reagent stabilities were in excess of 40 days. Mean analytical recoveries were 102% +/- 4% (SD), and there was no lack of parallelism. Hemolysis, lipemia, and bilirubin did not interfere. Both plasma anticoagulated with heparin or EDTA and serum from plain or serum-separation tubes were acceptable as sample matrices. Comparison with the Beekman Array(R) method gave a Passing and Bablok regression of: Dimension analyzer = 1.01Beckman + 7.1 (n = 103), using a common calibrator. We conclude that the prealbumin method is appropriate for clinical use according to the analytical criteria used in this study.
引用
收藏
页码:1316 / 1324
页数:9
相关论文
共 50 条
[21]   Verification of automated latex-enhanced particle immunoturbidimetric D-Dimer assays on different analytical platforms and comparability of test results [J].
Lapic, Ivana ;
Herak, Desiree Coen ;
Prpic, Snjezana ;
Prce, Andrea ;
Rascanec, Vanja ;
Zadro, Renata ;
Rogic, Dunja .
BIOCHEMIA MEDICA, 2020, 30 (03) :1-9
[22]   Determination of adiponectin in serum using a latex particle-enhanced turbidimbtric immunoassay with an automated analyzer [J].
Nishimura, Ayako ;
Sawai, Tokio .
CLINICA CHIMICA ACTA, 2006, 371 (1-2) :163-168
[23]   Development of an automated quantitative latex immunoassay for myoglobin with performance equivalent to heterogeneous immunoassays. [J].
Ash, J ;
Baxevanakis, G ;
Usategui, M .
CLINICAL CHEMISTRY, 1998, 44 :A128-A129
[24]   Clinical utility of urinary liver-type fatty acid binding protein measured by latex-enhanced turbidimetric immunoassay in chronic kidney disease [J].
Kamijo-Ikemori, Atsuko ;
Sugaya, Takeshi ;
Yoshida, Maki ;
Hoshino, Seiko ;
Akatsu, Satoshi ;
Yamazaki, Satoshi ;
Kimura, Kenjiro ;
Shibagaki, Yugo .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (10) :1645-1654
[25]   Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade dimension(R) analyzer [J].
Holownia, P ;
Bishop, E ;
Newman, DJ ;
John, WG ;
Price, CP .
CLINICAL CHEMISTRY, 1997, 43 (01) :76-84
[26]   Latex-enhanced immunoturbidimetric assay for procalcitonin: Methods comparison, analytical and clinical performance [J].
Ribeiro, R. ;
Queiroz, C. ;
Pereira, C. ;
Bartolo, R. ;
Marques, G. ;
Chaves, C. ;
Fontes, F. .
CLINICA CHIMICA ACTA, 2019, 493 :S30-S31
[27]   Latex-enhanced immunoturbidimetry allows D-dimer determination in plasma and serum samples [J].
Korte, W ;
Riesen, W .
CLINICAL CHEMISTRY, 2000, 46 (06) :871-872
[28]   AUTOMATED LATEX NEPHELOMETRIC IMMUNOASSAY FOR THE MEASUREMENT OF SERUM LIPOPROTEIN(A) [J].
BORQUE, L ;
RUS, A ;
DELCURA, J ;
MASIDE, C ;
ESCANERO, J .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1993, 7 (02) :105-110
[29]   AUTOMATED LATEX NEPHELOMETRIC IMMUNOASSAY OF THEOPHYLLINE IN HUMAN SERUM [J].
BORQUE, L ;
RUS, A ;
MASIDE, C ;
DELCURA, J .
EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1992, 30 (05) :307-309
[30]   Development and applications of latex piezoelectric immunoassay [J].
Kurosawa, S ;
Kamo, N ;
Arimura, T ;
Sekiya, A .
ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 :101-ENVR