Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique

被引:45
作者
Boachie-Adjei, O [1 ]
Girardi, FP [1 ]
Bansal, M [1 ]
Rawlins, BA [1 ]
机构
[1] Cornell Univ, Hosp Special Surg, Sch Med, Scoliosis Serv, New York, NY 10021 USA
来源
JOURNAL OF SPINAL DISORDERS | 2000年 / 13卷 / 06期
关键词
adult spinal deformity; pedicle screws; free-hand anatomic technique;
D O I
10.1097/00002517-200012000-00005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
A prospective study of 50 adults treated with fusion, realignment, and segmental spinal instrumentation for spinal deformity was conducted to assess the safety, accuracy, and efficacy of the free-hand pedicle screw placement technique. Postoperative computed tomographic scans were performed to evaluate the placement of 282 screws and were correlated with patients' clinical outcomes. Five screws were placed at T12, 26 at L1, 39 at L2, 48 at L3, 73 at L4, 35 at L5, and 50 at S1. Nine screws (3%) were misplaced and included three screws (1.06%) that violated the medial wall with no clinical sequelae or revision surgery needed. There were no neurologic deficits related to screw placement. The free-hand technique is a safe and cost-effective method for pedicular screw placement during surgery for adult spine deformities.
引用
收藏
页码:496 / 500
页数:5
相关论文
共 28 条
[1]   COMPUTER-ASSISTED PEDICLE SCREW FIXATION - A FEASIBILITY STUDY [J].
AMIOT, LP ;
LABELLE, H ;
DEGUISE, JA ;
SATI, M ;
BRODEUR, P ;
RIVARD, CH .
SPINE, 1995, 20 (10) :1208-1212
[2]   USE OF A FRAMELESS, ARMLESS STEREOTAXIC WAND FOR BRAIN-TUMOR LOCALIZATION WITH 2-DIMENSIONAL AND 3-DIMENSIONAL NEUROIMAGING [J].
BARNETT, GH ;
KORMOS, DW ;
STEINER, CP ;
WEISENBERGER, J .
NEUROSURGERY, 1993, 33 (04) :674-678
[3]  
Berlemann U, 1997, J SPINAL DISORD, V10, P117
[4]   STIMULUS-EVOKED EMG MONITORING DURING TRANSPEDICULAR LUMBOSACRAL SPINE INSTRUMENTATION - INITIAL CLINICAL-RESULTS [J].
CALANCIE, B ;
MADSEN, P ;
LEBWOHL, N .
SPINE, 1994, 19 (24) :2780-2786
[5]   In vitro simulation - Early results of stereotaxy for pedicle screw placement [J].
Carl, AL ;
Khanuja, HS ;
Sachs, BL ;
Gatto, CA ;
vomLehn, J ;
Vosburgh, K ;
Schenck, J ;
Lorensen, W ;
Rohling, K ;
Disler, D .
SPINE, 1997, 22 (10) :1160-1164
[6]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[7]  
DARDEN BV, 1996, 31 ANN M SCOL RES SO
[8]   Anatomic relations between the lumbar pedicle and the adjacent neural structures [J].
Ebraheim, NA ;
Xu, RM ;
Darwich, M ;
Yeasting, RA .
SPINE, 1997, 22 (20) :2338-2341
[9]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[10]  
Foley KT, 1996, NEUROSURG CLIN N AM, V7, P171