Dynode-timing method for PET block detectors

被引:1
|
作者
Bauer, Florian [1 ,2 ]
Zhang, Nan [2 ]
Schmand, Matthias [2 ]
Loope, Michael [2 ]
Eriksson, Lars [1 ,2 ]
Aykac, Mehmet [2 ]
机构
[1] Univ Stockholm, Dept Phys, SE-10691 Stockholm, Sweden
[2] Siemens Med Sol, Mol Imaging, Knoxville, TN 37932 USA
关键词
detectors; dynode-timing; high resolution; positron emission tomography (PET); small animal; SPECT;
D O I
10.1109/TNS.2007.910879
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The focus of this paper is the investigation of a new dynode-timing technique optimized for PET block detectors. This method allows utilization of dynode signals from single but especially multiple photo-multiplier tubes (PMTs), operated with negative high-voltage. The technique will provide an event-timing trigger without deteriorating the anode signal. A printed circuit board has been developed and built for this investigation. Benchmark measurements have been performed, comparing timing of the anode signal with timing of the inverted last-dynode signal and timing of the dynode signal extracted via a newly developed LVPECL-logic based board. Timing measurements were performed with plastic as well as LSO scintillators. From single PMT measurements we find a 30 ps improvement with the dynode-timing method compared to the standard anode timing with two Photonis XP2020Q PMTs with LSO (10 mm x 10 mm x 10 ram). For a quad-PMT block detector, assembled of four Hamamatsu R9800 with a Hi-Rez block, the timing-resolution improves similar to 10%, by 43 ps compared to the standard anode timing.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 50 条
  • [31] Influence of malfunctioning block detectors on the calculation of single detector efficiencies in PET
    Ferreira, N.C.
    Trebossen, R.
    Gregoire, M.-C.
    Bendriem, B.
    IEEE Transactions on Nuclear Science, 1999, 46 (4 II): : 1062 - 1069
  • [32] Image blurring due to light-sharing in PET block detectors
    St James, S
    Thompson, CJ
    MEDICAL PHYSICS, 2006, 33 (02) : 405 - 410
  • [33] Optimized Light Sharing Module for High Resolution PET Block Detectors
    Steinbach, Cecilia O.
    Erdei, Gabor
    Ujhelyi, Ferenc
    Major, Peter
    Lorincz, Emoke
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 507 - 512
  • [34] EFFECT OF INDEX OF REFRACTION ON DETECTOR ELEMENT IDENTIFICATION IN PET BLOCK DETECTORS
    TORNAI, MP
    HOFFMAN, EJ
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P180 - P180
  • [35] Digital Time Alignment of High Resolution PET Inveon Block Detectors
    Lenox, M. W.
    Atkins, B. E.
    Pressley, D. R.
    McFarland, A.
    Newport, D. F.
    Siegel, S. B.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2450 - 2453
  • [36] Influence of malfunctioning block detectors on the calculation of single detector efficiencies in PET
    Ferreira, NC
    Trébossen, R
    Grégoire, MC
    Bendriem, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1062 - 1069
  • [37] A method for determination of the timing stability of PET scanners
    Thompson, CJ
    Goertzen, AL
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (08) : 1053 - 1057
  • [38] Optimizing the timing resolution of SiPM sensors for use in TOF-PET detectors
    Vinke, R.
    Lohner, H.
    Schaart, D. R.
    van Dam, H. T.
    Seifert, S.
    Beekman, F. J.
    Dendooven, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 188 - 191
  • [39] Ultra Precise Timing with SiPM-Based TOF PET Scintillation Detectors
    Seifert, Stefan
    Vinke, Ruud
    van Dam, Herman T.
    Loehner, Herbert
    Dendooven, Peter
    Beekman, Freek J.
    Schaart, Dennis R.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2329 - +
  • [40] Signal Analysis for Improved Timing Resolution with Scintillation Detectors for TOF PET Imaging
    Wiener, R. I.
    Kaul, M.
    Surti, S.
    Karp, J. S.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1991 - 1995